A Case-Matched Controlled Study on High-Voltage Electrical Injuries vs Thermal Burns

被引:40
作者
Handschin, Alexander E. [1 ]
Vetter, Sebastian [1 ]
Jung, Florian J. [1 ]
Guggenheim, Merlin [1 ]
Kuenzi, Walter [1 ]
Giovanoli, Pietro [1 ]
机构
[1] Univ Zurich Hosp, Dept Surg, Div Plast & Reconstruct Surg, Burns Unit, CH-8091 Zurich, Switzerland
关键词
MICROVASCULAR RECONSTRUCTION; COVERAGE;
D O I
10.1097/BCR.0b013e3181a289a6
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The aim of this study was to provide an increased level of evidence on surgical management of high-tension electrical injuries compared with thermal burns using a case-controlled study design. Sixty-eight patients (64 males, 4 females, aged 33.7 +/- 13 years) with high-tension electrical burns were matched for age, gender, and burnt extent with a cohort of patients sustaining thermal burns. Data were analyzed for cause of accident (occupational vs nonoccupational), concomitant injuries, extent of burn and burn depth, surgical management, complications, and hospital stay. High-tension electrical burn patients required an average of 5.2 +/- 4 operations (range, 1-23 operations) compared with 3.3 +/- 1.9 (range, 1-10 operations) after thermal burns (P = .0019). Amputation rates (19.7% vs 1.5%), escharotomy/fasciotomy rates (47% vs 21%), and total hospitalization days (44 d vs 32 d) were significantly higher in high-tension electrical injuries (P < .05). Creatinine kinase levels were significantly elevated during the first 2 days in patients with subsequent amputations. Free flap failure was observed during the first 4 weeks after the trauma, whereas no flap failure occurred at later stages. Local, pedicled, and distant flaps were used in 15% of the patients. The mortality in both groups was 13.2% vs 11%, respectively (nonsignificant). High-voltage electrical injury remains a complex surgical challenge. When performing free flap coverage, caution must be taken for a vulnerable phase lasting tip to 4 weeks after the trauma. This phase is likely the result of a progressive intima lesion, potentially hazardous to microvascular reconstruction. The use of pedicle flaps may resemble an alternative to free flaps during this period. (J Burn Care Res 2009;30:400-407)
引用
收藏
页码:400 / 407
页数:8
相关论文
共 26 条
[1]   Electrical injuries: A 20-year review [J].
Arnoldo, BD ;
Purdue, GF ;
Kowalske, K ;
Helm, PA ;
Burris, A ;
Hunt, JL .
JOURNAL OF BURN CARE & REHABILITATION, 2004, 25 (06) :479-484
[2]   Distant pedicle flaps for soft tissue coverage of severely burned hands: an old idea revisited [J].
Barillo, DJ ;
Arabitg, R ;
Cancio, LC ;
Goodwin, CW .
BURNS, 2001, 27 (06) :613-619
[3]   One hundred ninety-five cases of high-voltage electric injury [J].
Cancio, LC ;
Jimenez-Reyna, JF ;
Barillo, DJ ;
Walker, SC ;
McManus, AT ;
Vaughan, GM .
JOURNAL OF BURN CARE & REHABILITATION, 2005, 26 (04) :331-340
[4]   EARLY FREE-FLAP COVERAGE OF ELECTRICAL AND THERMAL BURNS [J].
CHICK, LR ;
LISTER, GD ;
SOWDER, L .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1992, 89 (06) :1013-1019
[5]  
DAMATO TA, 1994, J NATL MED ASSOC, V86, P535
[6]   Factors influencing the sequelae of high tension electrical injuries [J].
Ferreiro, I ;
Meléndez, J ;
Regalado, J ;
Béjar, FJ ;
Gabilondo, FJ .
BURNS, 1998, 24 (07) :649-653
[7]   Electric burns:: high- and low-tension injuries [J].
García-Sánchez, V ;
Morell, PG .
BURNS, 1999, 25 (04) :357-360
[8]  
Haberal Mehmet A., 1995, Journal of Burn Care and Rehabilitation, V16, P43, DOI 10.1097/00004630-199501000-00008
[9]   Surgical treatment of high-voltage electrical injuries [J].
Handschin, A. E. ;
Jung, F. J. ;
Guggenheim, M. ;
Moser, V. ;
Wedler, V. ;
Contaido, C. ;
Kuenzi, W. ;
Giovanoli, P. .
HANDCHIRURGIE MIKROCHIRURGIE PLASTISCHE CHIRURGIE, 2007, 39 (05) :345-349
[10]   ELECTRICAL INJURIES - MORBIDITY, OUTCOME AND TREATMENT RATIONALE [J].
HUSSMANN, J ;
KUCAN, JO ;
RUSSELL, RC ;
BRADLEY, T ;
ZAMBONI, WA .
BURNS, 1995, 21 (07) :530-535