The performance of a CMOS flatpanel imager from Hamamatsu Photonics (C7942) has been tested in various synchrotron radiation experiments. This detector has a detection area of about 120 mm x 120 mm with 0.05 mm pixels, and a frame rate of 2 s(-1). The commercially available product was insensitive to X-rays with an energy lower than 15 keV, but slight modifications solved this problem. Images obtained in small-angle scattering, protein crystallography and medical imaging experiments were all of high quality. The fast readout and the large area are advantageous in real-time imaging. Although its noise level is higher than the area detectors that are currently used in synchrotron radiation experiments, it is particularly useful in experiments where other bulky detectors cannot be used. Its relatively low price (about USD 30000) makes it a unique option in the choice of detectors.
引用
收藏
页码:347 / 352
页数:6
相关论文
共 13 条
[1]   LARGE-APERTURE TV DETECTOR WITH A BERYLLIUM-WINDOWED IMAGE INTENSIFIER FOR X-RAY-DIFFRACTION [J].
AMEMIYA, Y ;
ITO, K ;
YAGI, N ;
ASANO, Y ;
WAKABAYASHI, K ;
UEKI, T ;
ENDO, T .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1995, 66 (02) :2290-2294
[3]  
DORENZO S, 1993, HEAVY SCINTILLATORS, P125
[4]   Construction and commissioning of a 215-m-long beamline at SPring-8 [J].
Goto, S ;
Takeshita, K ;
Suzuki, Y ;
Ohashi, H ;
Asano, Y ;
Kimura, H ;
Matsushita, T ;
Yagi, N ;
Isshiki, M ;
Yamazaki, H ;
Yoneda, Y ;
Umetani, K ;
Ishikawa, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 :682-685
[5]   High-resolution CMOS imaging detector [J].
Graeve, T ;
Weckler, GP .
MEDICAL IMAGING 2001: PHYSICS OF MEDICAL IMAGING, 2001, 4320 :68-76
[6]   CHARGE-COUPLED-DEVICE X-RAY-DETECTORS FOR MACROMOLECULAR CRYSTALLOGRAPHY [J].
GRUNER, SM ;
EALICK, SE .
STRUCTURE, 1995, 3 (01) :13-15
[7]   Present status of high flux beamline (BL40XU) at SPring-8 [J].
Inoue, K ;
Oka, T ;
Suzuki, T ;
Yagi, N ;
Takeshita, K ;
Goto, S ;
Ishikawa, T .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 467 :674-677
[8]   X-ray imaging with submicrometer resolution employing transparent luminescent screens [J].
Koch, A ;
Raven, C ;
Spanne, P ;
Snigirev, A .
JOURNAL OF THE OPTICAL SOCIETY OF AMERICA A-OPTICS IMAGE SCIENCE AND VISION, 1998, 15 (07) :1940-1951
[9]   The finer things in X-ray diffraction data collection [J].
Pflugrath, JW .
ACTA CRYSTALLOGRAPHICA SECTION D-BIOLOGICAL CRYSTALLOGRAPHY, 1999, 55 :1718-1725
[10]   Coupling format variations in x-ray detectors based on charge coupled devices [J].
Tate, MW ;
Gruner, SM ;
Eikenberry, EF .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01) :47-54