Cardiac Power Output during Dobutamine Stress Test in Horses

被引:3
|
作者
Sandersen, Charlotte [1 ]
McEntee, Kathleen
Deleuze, Stefan
Detilleux, Johanne [2 ]
Amory, Helene
机构
[1] Univ Liege, Fac Vet Med, Dept Clin Sci, Equine Clin, B-4000 Liege, Belgium
[2] Univ Liege, Fac Vet Med, Dept Anim Prod, B-4000 Liege, Belgium
关键词
Horse; Heart disease; Stress echocardiography; Thermodilution; Dobutamine; Atropine; PUMPING CAPABILITY; DOPPLER-ECHOCARDIOGRAPHY; PERFORMANCE; PROGNOSIS; RESERVE; INDEXES;
D O I
10.1016/j.jevs.2009.02.005
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Although echocardiography has greatly improved the diagnostic possibilities in equine medicine, determining the prognosis remains a difficult task. In humans, maximal cardiac power output (CPO) has been described as a powerful Indicator of exercise capability and outcome in heart disease. The aim of the study is to describe the measurement of CPO by echocardiography and by thermodilution in healthy horses. Six healthy horses were Studied. Cardiac output (CO) was measured by thermodilution and Doppler echocardiography at rest during a pharmacologic Stress test consisting of and 35 mu g/kg atropine followed by incremental steps 2, 4, 6, and 8 mu g/kg/min of dobutamine infusion. Mean arterial pressure (MP) was measured invasively by a catheter introduced into the transverse facial artery. CPO was calculated as the product of CO and MAP. Baseline CPO measured by thermodilution and. by Doppler echocardiography was 10.7 +/- 3.3 and 13.7 +/- 4.5 watts, respectively. CPO increased significantly with pharmacologic stimulation and reached maximal CPO of 66.4 +/- 3.6 and 60.4 +/- 5.1 watts when measured by thermodilution and Doppler echocardiography, respectively. This study describes an estimation of CPO in horses. Further studies should demonstrate the usefulness of CPO as a predictive indicator in horses suffering from cardiac disease.
引用
收藏
页码:219 / 222
页数:4
相关论文
共 50 条
  • [41] Peak cardiac power output-to-left ventricular mass during dobutamine echocardiography for risk stratification of patients with advanced heart failure
    Dini, F. L.
    Sorbo, S.
    Morrone, D.
    Guarini, G.
    Scali, M. C.
    Marzilli, M.
    Cortigiani, L.
    EUROPEAN HEART JOURNAL, 2014, 35 : 34 - 34
  • [42] TILTING OF THE CARDIAC AXIS DURING DOBUTAMINE STRESS ECHOCARDIOGRAPHY: POTENTIAL MARKER OF ISCHEMIA
    Gunta, Preetham
    Lopez-Candales, Angel
    Baweja, Paramdeep
    Sweeney, Michael
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 2530 - 2530
  • [43] Pulmonary artery wedge pressure measurement during pharmacological stress induction with dobutamine and dobutamine/atropine in horses with and without heart disease.
    Gehlen, H.
    Groner, U.
    Rohn, K.
    Stadler, P.
    DEUTSCHE TIERARZTLICHE WOCHENSCHRIFT, 2006, 113 (07): : 255 - 263
  • [44] Tilting of the Cardiac Axis During Dobutamine Stress Echocardiography: Potential Marker for Ischemia
    Gunta, Preetham
    Lopez-Candales, Angel
    Baweja, Paramdeep
    Sweeney, Michael
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (06)
  • [45] Fatal ventricular fibrillation during a low-dose dobutamine stress test
    Varga, A
    Picano, E
    Lakatos, F
    AMERICAN JOURNAL OF MEDICINE, 2000, 108 (04): : 352 - 353
  • [46] Regional wall motion changes with dobutamine as a pharmacological stress test during cardiac catheterization in patients with significant coronary artery disease
    Wagdi, P
    Fluri, M
    Rouvinez, G
    MEier, B
    JAPANESE HEART JOURNAL, 1996, 37 (06): : 847 - 853
  • [47] Sinus of valsalva aneurysm presenting as myocardial infarction during dobutamine stress test
    Ferreira, AC
    deMarchena, E
    Mayor, M
    Bolooki, H
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1996, 39 (04): : 400 - 402
  • [48] Effect of atropine-dobutamine stress test on left ventricular echocardio graphic parameters in untrained warmblood horses
    Sandersen, CF
    Detilleux, J
    De Moffarts, B
    Van Loon, G
    Amory, H
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2006, 20 (03) : 575 - 580
  • [49] DISTRIBUTION OF CARDIAC-OUTPUT IN ANESTHETIZED HORSES
    STADDON, GE
    WEAVER, BMQ
    WEBB, AI
    RESEARCH IN VETERINARY SCIENCE, 1979, 27 (01) : 38 - 45
  • [50] Noninvasive Cardiac Output Estimation Evaluated from Spiroergometric Stress Test
    Stork, Milan
    Novak, Jaroslav
    Zeman, Vaclav