Assessment of monitored energy use and thermal comfort conditions in mosques in hot-humid climates

被引:69
作者
Al-Homoud, Mohammad S. [1 ]
Abdou, Adel A. [1 ]
Budaiwi, Ismail M. [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Architectural Engn Dept, Dhahran 31261, Saudi Arabia
关键词
Thermal comfort; Energy use; Mosques; Intermittent operation; Hot-humid climate; Saudi Arabia; CONTROL STRATEGIES; BUILDINGS;
D O I
10.1016/j.enbuild.2008.12.005
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
In harsh climatic regions, buildings require air-conditioning in order to provide an acceptable level of thermal comfort. In many situations buildings are over cooled or the HVAC system is kept running for a Much longer time than needed. In some other situations thermal comfort is not achieved due to improper operation practices coupled with poor maintenance and even lack it, and consequently inefficient air-conditioning systems. Mosques represent one type of building that is characterized by their unique intermittent operating schedule determined by prayer times, which vary continuously according to the local solar time. This paper presents the results of a study designed to monitor energy use and thermal comfort conditions of a number of mosques in a hot-humid climate so that both energy efficiency and the quality of thermal comfort conditions especially during Occupancy periods ill Such intermittently operated buildings call be assessed accurately. (C) 2009 Published by Elsevier B.V.
引用
收藏
页码:607 / 614
页数:8
相关论文
共 22 条
[1]   Measurement of acoustical characteristics of mosques in Saudi Arabia [J].
Abdou, AA .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (03) :1505-1517
[2]  
Abdou Al-Homoud A.A., 2005, ENG SCI J, V16, P165
[3]  
Al-Homoud M.S., 2005, THERMAL DESIGN AIR C
[4]  
Al-Homoud MS., 2005, JKAU: Eng. Sci, V16, P185
[5]  
American Society of Heating Refrigerating Air-Conditioning Engineers, 2005, ASHRAE HDB FUND
[6]   An approach to investigate and remedy thermal-comfort problems in buildings [J].
Budaiwi, Ismail M. .
BUILDING AND ENVIRONMENT, 2007, 42 (05) :2124-2131
[7]  
Charles Kate E., 2003, IRC Research Report RR-162
[8]  
Cheng V., 2006, ARCHIT SCI REV, V49, P179, DOI DOI 10.3763/ASRE.2006.4924
[9]   EXPERIMENTAL STUDIES ON AIR DIFFUSION OF A LINEAR DIFFUSER AND ASSOCIATED THERMAL COMFORT INDEXES IN AN AIR-CONDITIONED SPACE [J].
CHOW, WK ;
WONG, LT .
BUILDING AND ENVIRONMENT, 1994, 29 (04) :523-530
[10]   Thermal comfort in naturally ventilated buildings: revisions to ASHRAE Standard 55 [J].
de Dear, RJ ;
Brager, GS .
ENERGY AND BUILDINGS, 2002, 34 (06) :549-561