Setup errors in cone-beam computed tomography and their effects on acute radiation toxicity in cervical cancer radiotherapy

被引:11
|
作者
Xin, S. [1 ]
机构
[1] Hebei Med Univ, Tangshan Workers Hosp, Dept Radiol, Tangshan, Hebei, Peoples R China
关键词
Cervical cancer; Cone-beam computed tomography; Image-guided radiation therapy; Setup error;
D O I
10.4238/2015.September.21.4
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This study aimed to evaluate cone-beam computed tomography setup errors during cervical cancer treatment and the effects of these errors on acute radiation toxicity and treatment efficacy. A total of 170 cervical cancer patients were randomly divided into imageguided radiation therapy (IGRT; 86 patients) and intensity-modulated radiation therapy (IMRT; 84 patients) groups to receive IGRT and IMRT, respectively. After correcting setup errors for the 86 patients in the IGRT group, the X-, Y- and Z-axis errors were smaller than the corresponding errors before correction (P < 0.01, P < 0.05, and P < 0.05, respectively). The setup errors unevenly influenced the affected organs and dosage distributions in the targeted regions. The frequencies of patients with grade 0 or I urinary toxicity were 86.0% (74/86) and 44.0% (37/84) in the IGRT and IMRT groups, respectively (P < 0.01), whereas the frequencies of patients with grade 0 or I gastrointestinal toxicity were 83.7% (72/86) and 53.6% (45/84) in the IGRT and IMRT groups, respectively (P < 0.01). The two groups had similar response rates (P > 0.05). IGRT significantly corrected and reduced setup errors during cervical cancer treatment and enhanced the dosage distribution accuracy within the affected organs and targeted regions. IGRT can reduce the adverse effect of radiotherapy, thereby achieving improved efficacy during cervical cancer treatment.
引用
收藏
页码:10937 / 10943
页数:7
相关论文
共 50 条
  • [41] Radiation doses in cone-beam breast computed tomography: A Monte Carlo simulation study
    Yi, Ying
    Lai, Chao-Jen
    Han, Tao
    Zhong, Yuncheng
    Shen, Youtao
    Liu, Xinming
    Ge, Shuaiping
    You, Zhicheng
    Wang, Tianpeng
    Shaw, Chris C.
    MEDICAL PHYSICS, 2011, 38 (02) : 589 - 597
  • [42] Intraoperative patient radiation dose from cone-beam computed tomography in thoracic surgery
    Kohmaru, Shinya
    Saito, Yuichi
    Takata, Takeshi
    Morita, Shizuka
    Takeyama, Ryo
    Kanamoto, Yasuyuki
    Nishida, Tomoki
    Dejima, Hitoshi
    Yamauchi, Yoshikane
    Kobayashi, Ikuo
    Kawamura, Masafumi
    Sakao, Yukinori
    JOURNAL OF CARDIOTHORACIC SURGERY, 2024, 19 (01)
  • [43] Optimizing image acquisition settings for cone-beam computed tomography in supine and prone breast radiotherapy
    De Puysseleyr, Annemieke
    Veldeman, Liv
    Bogaert, Evelien
    De Wagter, Carlos
    De Neve, Wilfried
    RADIOTHERAPY AND ONCOLOGY, 2011, 100 (02) : 227 - 230
  • [44] Commissioning experience with cone-beam computed tomography for image-guided radiation therapy
    Lehmann, Joerg
    Perks, Julian
    Semon, Sheldon
    Harse, Rick
    Purdy, James A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2007, 8 (03): : 21 - 36
  • [45] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Faccioli, Niccolo
    Foti, Giovanni
    Barillari, Marco
    Atzei, Andrea
    Mucelli, Roberto Pozzi
    SKELETAL RADIOLOGY, 2010, 39 (11) : 1087 - 1095
  • [46] Cone-beam Computed Tomography of the Paranasal Sinuses: Comparison Study with Multidetector Computed Tomography
    Kei, P. L.
    Tan, J. S. P.
    Leong, J. L.
    Kwok, Y. M.
    Lim, W. E. H.
    Chan, L. L.
    HONG KONG JOURNAL OF RADIOLOGY, 2013, 16 (02): : 110 - 116
  • [47] Artifacts in orthodontic bracket systems in cone-beam computed tomography and multislice computed tomography
    Hirschinger, Veronika
    Hanke, Sebastian
    Hirschfelder, Ursula
    Hofmann, Elisabeth
    JOURNAL OF OROFACIAL ORTHOPEDICS-FORTSCHRITTE DER KIEFERORTHOPADIE, 2015, 76 (02): : 152 - 163
  • [48] CONE-BEAM COMPUTED TOMOGRAPHIC IMAGE GUIDANCE FOR LUNG CANCER RADIATION THERAPY
    Bissonnette, Jean-Pierre
    Purdie, Thomas G.
    Higgins, Jane A.
    Li, Winnie
    Bezjak, Andrea
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2009, 73 (03): : 927 - 934
  • [49] Finger fractures imaging: accuracy of cone-beam computed tomography and multislice computed tomography
    Niccolò Faccioli
    Giovanni Foti
    Marco Barillari
    Andrea Atzei
    Roberto Pozzi Mucelli
    Skeletal Radiology, 2010, 39 : 1087 - 1095
  • [50] ADAPTIVE-PREDICTIVE ORGAN LOCALIZATION USING CONE-BEAM COMPUTED TOMOGRAPHY FOR IMPROVED ACCURACY IN EXTERNAL BEAM RADIOTHERAPY FOR BLADDER CANCER
    Lalondrelle, Susan
    Huddart, Robert
    Warren-Oseni, Karole
    Hansen, Vibeke Nordmark
    McNair, Helen
    Thomas, Karen
    Dearnaley, David
    Horwich, Alan
    Khoo, Vincent
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 79 (03): : 705 - 712