This study aimed to evaluate cone-beam computed tomography setup errors during cervical cancer treatment and the effects of these errors on acute radiation toxicity and treatment efficacy. A total of 170 cervical cancer patients were randomly divided into imageguided radiation therapy (IGRT; 86 patients) and intensity-modulated radiation therapy (IMRT; 84 patients) groups to receive IGRT and IMRT, respectively. After correcting setup errors for the 86 patients in the IGRT group, the X-, Y- and Z-axis errors were smaller than the corresponding errors before correction (P < 0.01, P < 0.05, and P < 0.05, respectively). The setup errors unevenly influenced the affected organs and dosage distributions in the targeted regions. The frequencies of patients with grade 0 or I urinary toxicity were 86.0% (74/86) and 44.0% (37/84) in the IGRT and IMRT groups, respectively (P < 0.01), whereas the frequencies of patients with grade 0 or I gastrointestinal toxicity were 83.7% (72/86) and 53.6% (45/84) in the IGRT and IMRT groups, respectively (P < 0.01). The two groups had similar response rates (P > 0.05). IGRT significantly corrected and reduced setup errors during cervical cancer treatment and enhanced the dosage distribution accuracy within the affected organs and targeted regions. IGRT can reduce the adverse effect of radiotherapy, thereby achieving improved efficacy during cervical cancer treatment.
引用
收藏
页码:10937 / 10943
页数:7
相关论文
共 50 条
  • [31] Clinical guidelines for dental cone-beam computed tomography
    Hayashi, Takafumi
    Arai, Yoshinori
    Chikui, Toru
    Hayashi-Sakai, Sachiko
    Honda, Kazuya
    Indo, Hiroko
    Kawai, Taisuke
    Kobayashi, Kaoru
    Murakami, Shumei
    Nagasawa, Masako
    Naitoh, Munetaka
    Nakayama, Eiji
    Nikkuni, Yutaka
    Nishiyama, Hideyoshi
    Shoji, Noriaki
    Suenaga, Shigeaki
    Tanaka, Ray
    ORAL RADIOLOGY, 2018, 34 (02) : 89 - 104
  • [32] Assessing pulp stones by cone-beam computed tomography
    Emmanuel João Nogueira Leal da Silva
    Marina C. Prado
    Polyane M. Queiroz
    Yuri Nejaim
    Danieli M. Brasil
    Francisco Carlos Groppo
    Francisco Haiter-Neto
    Clinical Oral Investigations, 2017, 21 : 2327 - 2333
  • [33] Evaluation of the pharyngeal recess with cone-beam computed tomography
    Erdem, Sule
    Zengin, Ayse Zeynep
    Erdem, Suheda
    SURGICAL AND RADIOLOGIC ANATOMY, 2020, 42 (11) : 1307 - 1313
  • [34] Stability of voxel values in cone-beam computed tomography
    Munetaka Naitoh
    Hidetoshi Aimiya
    Kazuhiko Nakata
    Kenichi Gotoh
    Eiichiro Ariji
    Oral Radiology, 2014, 30 : 147 - 152
  • [35] Cone-beam computed tomography of the head in standing equids
    M. D. Klopfenstein Bregger
    C. Koch
    R. Zimmermann
    D. Sangiorgio
    D. Schweizer-Gorgas
    BMC Veterinary Research, 15
  • [36] Cone-beam computed tomography of the maxillofacial region - an update
    Kau, Chung How
    Bozic, Marko
    English, Jeryl
    Lee, Robert
    Bussa, Harry
    Ellis, Randy K.
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2009, 5 (04) : 366 - 380
  • [37] Essentials of Algebraic Reconstruction in Cone-Beam Computed Tomography
    A. E. Chernukha
    A. I. Shestopalov
    A. I. Adarova
    R. V. Shershnev
    Ya. V. Kizilova
    S. N. Koryakin
    S. A. Ivanov
    A. N. Solovev
    Bulletin of the Lebedev Physics Institute, 2023, 50 : 438 - 444
  • [38] Assessing pulp stones by cone-beam computed tomography
    Nogueira Leal da Silva, Emmanuel Joao
    Prado, Marina C.
    Queiroz, Polyane M.
    Nejaim, Yuri
    Brasil, Danieli M.
    Groppo, Francisco Carlos
    Haiter-Neto, Francisco
    CLINICAL ORAL INVESTIGATIONS, 2017, 21 (07) : 2327 - 2333
  • [39] Evaluation of the pharyngeal recess with cone-beam computed tomography
    Şule Erdem
    Ayşe Zeynep Zengin
    Şuheda Erdem
    Surgical and Radiologic Anatomy, 2020, 42 : 1307 - 1313
  • [40] Motion Correction Algorithm for Cone-Beam Computed Tomography
    Lee, Jiyoung
    Kim, Jinwoo
    Cho, Minkook
    MEDICAL IMAGING 2024: PHYSICS OF MEDICAL IMAGING, PT 1, 2024, 12925