Setup errors in cone-beam computed tomography and their effects on acute radiation toxicity in cervical cancer radiotherapy

被引:11
|
作者
Xin, S. [1 ]
机构
[1] Hebei Med Univ, Tangshan Workers Hosp, Dept Radiol, Tangshan, Hebei, Peoples R China
关键词
Cervical cancer; Cone-beam computed tomography; Image-guided radiation therapy; Setup error;
D O I
10.4238/2015.September.21.4
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This study aimed to evaluate cone-beam computed tomography setup errors during cervical cancer treatment and the effects of these errors on acute radiation toxicity and treatment efficacy. A total of 170 cervical cancer patients were randomly divided into imageguided radiation therapy (IGRT; 86 patients) and intensity-modulated radiation therapy (IMRT; 84 patients) groups to receive IGRT and IMRT, respectively. After correcting setup errors for the 86 patients in the IGRT group, the X-, Y- and Z-axis errors were smaller than the corresponding errors before correction (P < 0.01, P < 0.05, and P < 0.05, respectively). The setup errors unevenly influenced the affected organs and dosage distributions in the targeted regions. The frequencies of patients with grade 0 or I urinary toxicity were 86.0% (74/86) and 44.0% (37/84) in the IGRT and IMRT groups, respectively (P < 0.01), whereas the frequencies of patients with grade 0 or I gastrointestinal toxicity were 83.7% (72/86) and 53.6% (45/84) in the IGRT and IMRT groups, respectively (P < 0.01). The two groups had similar response rates (P > 0.05). IGRT significantly corrected and reduced setup errors during cervical cancer treatment and enhanced the dosage distribution accuracy within the affected organs and targeted regions. IGRT can reduce the adverse effect of radiotherapy, thereby achieving improved efficacy during cervical cancer treatment.
引用
收藏
页码:10937 / 10943
页数:7
相关论文
共 50 条
  • [1] A prospective study to assess and quantify the setup errors with cone-beam computed tomography in head-and-neck cancer image-guided radiotherapy treatment
    Jain, Vidhi
    Soni, Tej Prakash
    Singh, Dinesh Kumar
    Patni, Nidhi
    Jakhotia, Naresh
    Gupta, Anil Kumar
    Gupta, Tara Chand
    Singhal, Harish
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2023, 19 (03) : 783 - 787
  • [2] Implementing cone-beam computed tomography-guided online adaptive radiotherapy in cervical cancer
    Shelley, Charlotte E.
    Bolt, Matthew A.
    Hollingdale, Rachel
    Chadwick, Susan J.
    Barnard, Andrew P.
    Rashid, Miriam
    Reinlo, Selina C.
    Fazel, Nawda
    Thorpe, Charlotte R.
    Stewart, Alexandra J.
    South, Chris P.
    Adams, Elizabeth J.
    CLINICAL AND TRANSLATIONAL RADIATION ONCOLOGY, 2023, 40
  • [3] Different setup errors assessed by weekly cone-beam computed tomography on different registration in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy
    Su, Jiqing
    Chen, Wen
    Yang, Huiyun
    Hong, Jidong
    Zhang, Zijian
    Yang, Guangzheng
    Li, Li
    Wei, Rui
    ONCOTARGETS AND THERAPY, 2015, 8 : 2545 - 2553
  • [4] Kilovoltage cone-beam computed tomography imaging dose estimation and optimization: Need of daily cone-beam computed tomography
    Trivedi, Gaurav
    Dixit, Chandra K.
    Oinam, Arun S.
    Kapoor, Rakesh
    Bahl, Amit
    JOURNAL OF CANCER RESEARCH AND THERAPEUTICS, 2019, 15 (03) : 470 - 474
  • [5] Radiation therapist perspectives on cone-beam computed tomography practices and response to information
    Gillan, Caitlin
    Li, Winnie
    Harnett, Nicole
    JOURNAL OF RADIOTHERAPY IN PRACTICE, 2013, 12 (03) : 237 - 244
  • [6] Patient radiation dose and protection from cone-beam computed tomography
    Li, Gang
    IMAGING SCIENCE IN DENTISTRY, 2013, 43 (02) : 63 - 69
  • [7] A Personalized Anisotropic Margin for Cervical Cancer Radiation Therapy Under the Guidance of Daily Iterative Cone-Beam Computed Tomography (iCBCT)
    Xiao, Haonan
    Guo, Qiufen
    Ma, Junjie
    Chen, Jian
    Xie, Peng
    Yin, Yong
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (09)
  • [8] A novel evaluation model of image registration for cone-beam computed tomography guided lung cancer radiotherapy
    Liu, Yimei
    Chen, Meining
    Fang, Jianlan
    Xiao, Liangjie
    Liu, Songran
    Li, Qiwen
    Qiu, Bo
    Huang, Runda
    Zhang, Jun
    Peng, Yinglin
    THORACIC CANCER, 2024, 15 (17) : 1333 - 1342
  • [9] Adaptive radiotherapy for prostate cancer using kilovoltage cone-beam computed tomography: First clinical results
    Nijkamp, Jasper
    Pos, Floris J.
    Nuver, Tonnis T.
    De Jong, Rianne
    Remeijer, Peter
    Sonke, Jan-Jakob
    Lebesque, Joos V.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (01): : 75 - 82
  • [10] Interfractional and intrafractional errors assessed by daily cone-beam computed tomography in nasopharyngeal carcinoma treated with intensity-modulated radiation therapy: a prospective study
    Lu, Heming
    Lin, Hui
    Feng, Guosheng
    Chen, Jiaxin
    Shu, Liuyang
    Pang, Qiang
    Cheng, Jinjian
    Peng, Luxing
    Wu, Danling
    Liao, Chaolong
    Mo, Ying
    JOURNAL OF RADIATION RESEARCH, 2012, 53 (06) : 954 - 960