Thermal analysis of closed feedwater heaters in nuclear power plants
被引:18
作者:
Alvarez-Fernandez, Mario
论文数: 0引用数: 0
h-index: 0
机构:
Santa Maria de Garona Nucl Power Plant, Dept Mech Maintenance, Burgos 09212, Spain
Univ Burgos, Escuela Politecn Super, Burgos 09006, SpainSanta Maria de Garona Nucl Power Plant, Dept Mech Maintenance, Burgos 09212, Spain
Alvarez-Fernandez, Mario
[1
,3
]
del Portillo-Valdes, Luis
论文数: 0引用数: 0
h-index: 0
机构:
Univ Basque Country, ETS Ingn, Bilbao 48013, SpainSanta Maria de Garona Nucl Power Plant, Dept Mech Maintenance, Burgos 09212, Spain
del Portillo-Valdes, Luis
[2
]
Alonso-Tristan, Cristina
论文数: 0引用数: 0
h-index: 0
机构:
Univ Burgos, Escuela Politecn Super, Burgos 09006, SpainSanta Maria de Garona Nucl Power Plant, Dept Mech Maintenance, Burgos 09212, Spain
Alonso-Tristan, Cristina
[3
]
机构:
[1] Santa Maria de Garona Nucl Power Plant, Dept Mech Maintenance, Burgos 09212, Spain
[2] Univ Basque Country, ETS Ingn, Bilbao 48013, Spain
[3] Univ Burgos, Escuela Politecn Super, Burgos 09006, Spain
Closed feedwater heater;
Nuclear power plant;
Overall heat transfer coefficient;
Thermodynamic properties of wet-steam;
DESIGN;
D O I:
10.1016/j.applthermaleng.2014.04.006
中图分类号:
O414.1 [热力学];
学科分类号:
摘要:
A model is introduced for the thermal analysis of closed feedwater heaters in which wet steam is extracted from the steam turbine (and piped into the heater). Where the fluid flowing through the steam turbine is wet steam, application of this model is of relevance to nuclear power plant diagnostics. At present, all feedwater heater calculations are performed by setting the stage moisture removal effectiveness, on the assumption that the mass flows and/or the enthalpy rates of the steam bled from the turbine are known values. Our model enables detection of multiple malfunctions, even where inaccurate readings may have been registered in the control room at an earlier point in time. Furthermore, there is no immediate need for on-site inspection, which is an important advantage in Boiling Water Reactor Power Plants where feedwater heaters are placed in high radiation dose areas. (C) 2014 Elsevier Ltd. All rights reserved.