Measurement of charged particle yields from PMMA irradiated by a 220 MeV/u 12C beam

被引:64
作者
Piersanti, L. [1 ,2 ]
Bellini, F. [3 ,4 ]
Bini, F. [5 ]
Collamati, F. [3 ,4 ]
De Lucia, E. [1 ]
Durante, M. [6 ]
Faccini, R. [3 ,4 ]
Ferroni, F. [3 ,4 ]
Fiore, S. [3 ]
Iarocci, E. [1 ,2 ]
La Tessa, C. [6 ]
Marafini, M. [3 ,7 ,8 ]
Mattei, I. [1 ,9 ]
Patera, V. [2 ,4 ,7 ,8 ]
Ortega, P. G. [10 ,11 ]
Sarti, A. [1 ,2 ]
Schuy, C. [6 ]
Sciubba, A. [2 ,4 ]
Vanstalle, M. [6 ]
Voena, C. [3 ,4 ]
机构
[1] Ist Nazl Fis Nucl, Lab Nazl Frascati, I-00044 Frascati, Italy
[2] Univ Roma La Sapienza, Dipartimento Sci Base & Applicate Ingn, I-00185 Rome, Italy
[3] Univ Roma La Sapienza, Dipartimento Fis, I-00185 Rome, Italy
[4] Ist Nazl Fis Nucl, Sez Roma, Rome, Italy
[5] Univ Roma La Sapienza, Dipartimento Ingn Meccan & Aerosp, I-00185 Rome, Italy
[6] GSI Darmstadt, Darmstadt, Germany
[7] Museo Stor Fis, Rome, Italy
[8] Ctr Studi & Ric E Fermi, Rome, Italy
[9] Roma Tre Univ Roma, Dipartimento Matemat & Fis, Rome, Italy
[10] CERN, Geneva, Switzerland
[11] IFIC CSIC UV, Valencia, Spain
关键词
drift chamber; LYSO; hadrontherapy; carbon ion beam; dose monitoring; PET MEASUREMENTS; ION;
D O I
10.1088/0031-9155/59/7/1857
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The radiation used in hadrontherapy treatments interacts with the patient body producing secondary particles, either neutral or charged, that can be used for dose and Bragg peak monitoring and to provide a fast feedback on the treatment plans. Recent results obtained from the authors on simplified setups (mono-energetic primary beams interacting with homogeneous tissue like target) have already indicated the correlation that exists between the flux of these secondaries coming from the target (e.g. protons and photons) and the position of the primary beam Bragg peak. In this paper, the measurements of charged particle fluxes produced by the interaction of a 220 MeV/u carbon ion beam at GSI, Darmstadt, with a polymethyl methacrylate target are reported. The emission region of protons (p), deuterons (d) and tritons (t) has been characterized using a drift chamber while the particle time-of-flight, used to compute the kinetic energy spectra, was measured with a LYSO scintillator.The energy released in the LYSO crystal was used for particle identification purposes. The measurements were repeated with the setup at 60 degrees and 90 degrees with respect to the primary beam direction. The accuracy on the fragments emission profile reconstruction and its relationship with the Bragg peak position have been studied. Based on the acquired experimental evidence, a method to monitor the dose profile and the position of the Bragg peak inside the target is proposed.
引用
收藏
页码:1857 / 1872
页数:16
相关论文
共 25 条
[1]   Performance of upstream interaction region detectors for the FIRST experiment at GSI [J].
Abou-Haidar, Z. ;
Agodi, C. ;
Alvarez, M. A. G. ;
Anelli, M. ;
Aumann, T. ;
Battistoni, G. ;
Bocci, A. ;
Bohlen, T. T. ;
Boudard, A. ;
Brunetti, A. ;
Carpinelli, M. ;
Cirrone, G. A. P. ;
Cortes-Giraldo, M. A. ;
Cuttone, G. ;
De Napoli, M. ;
Durante, M. ;
Fernandez-Garcia, J. P. ;
Finck, C. ;
Gallardo, M. I. ;
Golosio, B. ;
Iarocci, E. ;
Iazzi, F. ;
Ickert, G. ;
Introzzi, R. ;
Juliani, D. ;
Krimmer, J. ;
Kurz, N. ;
Labalme, M. ;
Leifels, Y. ;
Le Fevre, A. ;
Leray, S. ;
Marchetto, F. ;
Monaco, V. ;
Morone, M. C. ;
Oliva, P. ;
Paoloni, A. ;
Patera, V. ;
Piersanti, L. ;
Pleskac, R. ;
Quesada, J. M. ;
Randazzo, N. ;
Romano, F. ;
Rossi, D. ;
Rosso, V. ;
Rousseau, M. ;
Sacchi, R. ;
Sala, P. ;
Sarti, A. ;
Schuy, C. ;
Sciubba, A. .
JOURNAL OF INSTRUMENTATION, 2012, 7
[2]   Charged particle's flux measurement from PMMA irradiated by 80 MeV/u carbon ion beam [J].
Agodi, C. ;
Battistoni, G. ;
Bellini, F. ;
Cirrone, G. A. P. ;
Collamati, F. ;
Cuttone, G. ;
De Lucia, E. ;
De Napoli, M. ;
Di Domenico, A. ;
Faccini, R. ;
Ferroni, F. ;
Fiore, S. ;
Gauzzi, P. ;
Iarocci, E. ;
Marafini, M. ;
Mattei, I. ;
Muraro, S. ;
Paoloni, A. ;
Patera, V. ;
Piersanti, L. ;
Romano, F. ;
Sarti, A. ;
Sciubba, A. ;
Vitale, E. ;
Voena, C. .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (18) :5667-5678
[3]   Study of the time and space distribution of β+ emitters from 80 MeV/u carbon ion beam irradiation on PMMA [J].
Agodi, C. ;
Bellini, F. ;
Cirrone, G. A. P. ;
Collamati, F. ;
Cuttone, G. ;
De Lucia, E. ;
De Napoli, M. ;
Di Domenico, A. ;
Faccini, R. ;
Ferroni, F. ;
Fiore, S. ;
Gauzzi, P. ;
Iarocci, E. ;
Marafini, M. ;
Mattei, I. ;
Paoloni, A. ;
Patera, V. ;
Piersanti, L. ;
Romano, F. ;
Sarti, A. ;
Sciubba, A. ;
Voena, C. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2012, 283 :1-8
[4]  
Agodi C, 2012, JINST, V7
[5]   Radiotherapy with beams of carbon ions [J].
Amaldi, U ;
Kraft, G .
REPORTS ON PROGRESS IN PHYSICS, 2005, 68 (08) :1861-1882
[6]  
[Anonymous], 2002, Probabilistic Approach to Inverse Problems: Chapter for the International Handbook of Earthquake and Engineering Seismology, DOI [10.1016/S0074-6142(02)80219-4, DOI 10.1016/S0074-6142(02)80219-4]
[7]   Comparison of two dedicated 'in beam' PET systems via simultaneous imaging of 12C-induced β+-activity [J].
Attanasi, F. ;
Belcari, N. ;
Del Guerra, A. ;
Enghardt, W. ;
Moehrs, S. ;
Parodi, K. ;
Rosso, V. ;
Vecchio, S. .
PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (02) :N29-N35
[8]  
Battistoni G, 2007, AIP CONF PROC, V896, P31, DOI 10.1063/1.2720455
[9]   Extended calibration range for prompt photon emission in ion beam irradiation [J].
Bellini, F. ;
Boehlen, T. T. ;
Chin, M. P. W. ;
Collamati, F. ;
De Lucia, E. ;
Faccini, R. ;
Ferrari, A. ;
Lanza, L. ;
Mancini-Terracciano, C. ;
Marafini, M. ;
Mattei, I. ;
Morganti, S. ;
Ortega, P. G. ;
Patera, V. ;
Piersanti, L. ;
Russomando, A. ;
Sala, P. R. ;
Sarti, A. ;
Sciubba, A. ;
Camillocci, E. Solfaroli ;
Voena, C. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 745 :114-118
[10]   Charged particles in radiation oncology [J].
Durante, Marco ;
Loeffler, Jay S. .
NATURE REVIEWS CLINICAL ONCOLOGY, 2010, 7 (01) :37-43