Wear Behavior of Plasma Oxidized CoCrMo Alloy under Dry and Simulated Body Fluid Conditions

被引:18
作者
Celik, Ayhan [1 ]
Aslan, Mevra [1 ]
Yetim, Ali Fatih [2 ]
Bayrak, Ozgu [1 ]
机构
[1] Ataturk Univ, Fac Engn, Dept Mech Engn, TR-25240 Erzurum, Turkey
[2] Erzurum Tech Univ, Fac Engn & Architecture, Dept Mech Engn, TR-25700 Erzurum, Turkey
关键词
plasma oxidation; wear; CoCrMo; simulated body fluid; implant material; TRIBOLOGICAL PROPERTIES; ORTHOPEDIC MATERIALS; TI6AL4V ALLOY; MICROSTRUCTURE; CORROSION;
D O I
10.1016/S1672-6529(14)60035-4
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, CoCrMo alloy was oxidized in plasma environment at the temperatures of 600 degrees C to 800 degrees degrees C for 1 h to 5 h with 100% O-2 gas and its tribological behavior was investigated. After the plasma oxidizing process, the compound and diffusion layers were formed on the surface. XRD results show that Cr2O3, alpha-Co and epsilon-Co phases diffracted from the modified layers after plasma oxidizing. The untreated and treated CoCrMo samples were subjected to wear tests both in dry and simulated body fluid conditions, and normal loads of 2 N and 10 N were used. For the sliding wear test, alumina balls were used as counter materials. It was observed that the wear resistance of CoCrMo alloy was increased after the plasma oxidizing process. The lowest wear rate was obtained from the samples that were oxidized at 800 degrees C for 5 h. It was detected that both wear environment and load have significant effects on the wear behavior of this alloy, and the wear resistance of oxidized CoCrMo alloy is higher when oxide-based counterface is used. The wear rates of both untreated and plasma oxidized samples increase under high loads.
引用
收藏
页码:303 / 310
页数:8
相关论文
共 21 条
[1]  
Alsaran A, 2010, 5 NAT BIOM C IZM TUR, P57
[2]   Plasma-surface modification of biomaterials [J].
Chu, PK ;
Chen, JY ;
Wang, LP ;
Huang, N .
MATERIALS SCIENCE & ENGINEERING R-REPORTS, 2002, 36 (5-6) :143-206
[3]  
Gumusderelioglu M., 2002, TUBITAK, V7, P20
[4]   Passive and transpassive behaviour of CoCrMo in simulated biological solutions [J].
Hodgson, AWE ;
Kurz, S ;
Virtanen, S ;
Fervel, V ;
Olsson, COA ;
Mischler, S .
ELECTROCHIMICA ACTA, 2004, 49 (13) :2167-2178
[5]   Effect of the environment on wear ranking and corrosion of biomedical CoCrMo alloys [J].
Igual Munoz, A. ;
Mischler, S. .
JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2011, 22 (03) :437-450
[6]   How useful is SBF in predicting in vivo bone bioactivity? [J].
Kokubo, T ;
Takadama, H .
BIOMATERIALS, 2006, 27 (15) :2907-2915
[7]   High intensity plasma ion nitriding of orthopedic materials - Part II. Microstructural analysis [J].
Lanning, BR ;
Wei, RH .
SURFACE & COATINGS TECHNOLOGY, 2004, 186 (1-2) :314-319
[8]   The effects of calcium phosphate deposition upon corrosion of CoCr alloys and the potential for implant failure [J].
Lewis, AC ;
Heard, PJ .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2005, 75A (02) :365-373
[9]   Biomimetic Synthesis of Collagen/Nano-Hydroxyapitate Scaffold for Tissue Engineering [J].
Liu, Chao-zong .
JOURNAL OF BIONIC ENGINEERING, 2008, 5 (Suppl 1) :1-8
[10]   Plasma oxidation of Al thin films on Si substrates [J].
Lu, Fu-Hsing ;
Tsai, Hong-Dar ;
Chieh, Yu-Chih .
THIN SOLID FILMS, 2008, 516 (08) :1871-1876