Isolation and analysis of articular joints wear debris generated in vitro

被引:23
作者
Kowandy, C. [1 ]
Mazouz, H. [1 ]
Richard, C. [1 ]
机构
[1] Univ Technol Compiegne, LRM, CNRS, FRE 2833, F-60205 Compiegne, France
关键词
wear debris; artificial joints; separation methodology;
D O I
10.1016/j.wear.2006.03.029
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
The total replacement of damaged or diseased synovial joints represents one of the greatest advances in orthopaedic surgery of the 20th century. Whereas replacements are available for the shoulder, ankle, elbow, and knee, hip accounts particularly for the most surgical interventions. In France, 100,000 hip joints per year are replaced and all the implants consist of a sliding pair represented by a hard counter face, either metal or ceramic, and commonly a softer polymer. Ultra high molecular weight polyethylene (UHMWPE) was first used in joint replacement in the early 1960s. Since that time, it had been the dominant polymer for bearing surfaces in orthopaedic surgery. However, generation of UHMPWE wear debris from bearing surfaces in patients is the major problem for long term implants. Both volume and morphology of the wear particles determine the response of the body to debris, and subsequent effects on secure fixing. This paper presents a review of the type of particles most frequently found in biopsies of tissues from explanted prostheses. Indeed, the size and the amount of these debris are very important factors for a better understanding of wear and corrosion wear processes in artificial joints. Real wear particles are also described in this paper. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:966 / 970
页数:5
相关论文
共 18 条
[1]   The performance of gamma- and EtO-sterilised UHMWPE acetabular cups tested under severe simulator conditions. Part 2: wear particle characteristics with isolation protocols [J].
Affatato, S ;
Bersaglia, G ;
Emiliani, D ;
Foltran, I ;
Taddei, P ;
Reggiani, M ;
Ferrieri, P ;
Toni, A .
BIOMATERIALS, 2003, 24 (22) :4045-4055
[2]   Isolation and morphological characterisation of UHMWPE wear debris generated in vitro [J].
Affatato, S ;
Fernandes, B ;
Tucci, A ;
Esposito, L ;
Toni, A .
BIOMATERIALS, 2001, 22 (17) :2325-2331
[3]  
Ayel J., 1998, LUBRIFIANTS FLUIDES
[4]  
DOWSON D, 1998, HIST TRIBOLOGY, V11, P507
[5]   Mechanical behavior, wear surface morphology, and clinical performance of UHMWPE acetabular components after 10 years of implantation [J].
Edidin, AA ;
Rimnac, CM ;
Goldberg, VM ;
Kurtz, SM .
WEAR, 2001, 250 (PART 1) :152-158
[6]   In vivo metallic biomaterials and surface modification [J].
Hanawa, T .
MATERIALS SCIENCE AND ENGINEERING A-STRUCTURAL MATERIALS PROPERTIES MICROSTRUCTURE AND PROCESSING, 1999, 267 (02) :260-266
[7]  
*ISO CD, 1999, 1783 ISO CD
[8]  
LAFFARGUE P, 1998, METALS BIOMATERIALS
[9]  
MAZOUZ H, 2003, THESIS UTC
[10]  
MIYAZAKI T, 2001, ENG MAT, V192, P43