Reliability of the Osstell Implant Stability Quotient and Penguin Resonance Frequency Analysis to Evaluate Implant Stability

被引:23
作者
Buyukguclu, Gul
Ozkurt-Kayahan, Zeynep [1 ]
Kazazoglu, Ender [1 ]
机构
[1] Yeditepe Univ, Dept Prosthodont, Fac Dent, Bagdat Cad 238, TR-34728 Istanbul, Turkey
关键词
resonance frequency analysis; stability measurement; repeatability; TITANIUM IMPLANTS; INSERTION TORQUE; IN-VITRO; BONE; INTERFACE; TISSUE; MENTOR;
D O I
10.1097/ID.0000000000000766
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To evaluate the reliability of the Osstell implant stability quotient (ISQ) and Penguin resonance frequency analysis (RFA) devices in measuring implant stability. Materials and Methods: Forty implants were embedded in self-curing acrylic resin, soft-lining material, polyvinyl siloxane impression material, and polycarboxylate cement (n = 10). After the initial setting times were completed, the stability of each implant was measured with Osstell ISQ and Penguin RFA with 3 repeated measurements. The "intraclass correlation coefficient" evaluated the correspondence between the measurements (P < 0.05). Results: Polyvinyl siloxane impression material had lower ISQ values than soft-lining material, self-curing acrylic resin, and polycarboxylate cement in both devices (P < 0.05). The intraclass correlation was 1.00 in self-curing acrylic resin and 0.48 in polycarboxylate cement (P < 0.05) for Osstell. This value was 0.95 in self-curing acrylic resin and 0.38 in polycarboxylate cement (P < 0.05) for Penguin. There was no correlation between the repeated measurements in soft-lining material and polyvinyl siloxane impression material for both devices (P > 0.05). The repeatability was 0.90 for Osstell and 0.60 for Penguin (P < 0.05). Conclusions: Osstell ISQ and Penguin RFA are reliable only when the implants are embedded in stiff materials. Osstell ISQ is more reliable than Penguin RFA.
引用
收藏
页码:429 / 433
页数:5
相关论文
共 32 条
[1]   Assessment of Osstell (TM) and Periotest((R)) systems in measuring dental implant stability (in vitro study) [J].
Al-Jetaily, Samer ;
Al-Dosari, Abdullah AlFarraj .
SAUDI DENTAL JOURNAL, 2011, 23 (01) :17-21
[2]   OSSEOINTEGRATED TITANIUM IMPLANTS - REQUIREMENTS FOR ENSURING A LONG-LASTING, DIRECT BONE-TO-IMPLANT ANCHORAGE IN MAN [J].
ALBREKTSSON, T ;
BRANEMARK, PI ;
HANSSON, HA ;
LINDSTROM, J .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (02) :155-170
[3]   Validity and clinical significance of biomechanical testing of implant/bone interface [J].
Aparicio, Carlos ;
Lang, Niklaus R. ;
Rangert, Bo .
CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 :2-7
[4]  
Atsumi M, 2007, INT J ORAL MAX IMPL, V22, P743
[5]   Evaluation of the correlation between insertion torque and primary stability of dental implants using a block bone test [J].
Bayarchimeg, Dorjpalam ;
Namgoong, Hee ;
Kim, Byung Kook ;
Kim, Myung Duk ;
Kim, Sungtae ;
Kim, Tae-Il ;
Seol, Yang Jo ;
Lee, Yong Moo ;
Ku, Young ;
Rhyu, In-Chul ;
Lee, Eun Hee ;
Koo, Ki-Tae .
JOURNAL OF PERIODONTAL AND IMPLANT SCIENCE, 2013, 43 (01) :30-36
[6]   Resonance frequency analysis: a new diagnostic tool for dental ankylosis [J].
Bertl, Michael H. ;
Weinberger, Thomas ;
Schwarz, Kerstin ;
Gruber, Reinhard ;
Crismani, Adriano G. .
EUROPEAN JOURNAL OF ORAL SCIENCES, 2012, 120 (03) :255-258
[7]  
BRANEMARK P I, 1969, Scandinavian Journal of Plastic and Reconstructive Surgery, V3, P81
[8]  
Degidi M, 2010, INT J ORAL MAX IMPL, V25, P558
[9]   In vitro comparison of primary stability of two implant designs in D3 bone [J].
Gonzalez-Serrano, Jose ;
Ortega-Aranegui, Ricardo ;
Lopez-Quiles, Juan .
MEDICINA ORAL PATOLOGIA ORAL Y CIRUGIA BUCAL, 2017, 22 (04) :E473-E477
[10]   An Evaluation of the Resonance Frequency Analysis Device: Examiner Reliability and Repeatability of Readings [J].
Gupta, Rajiv Kumar ;
Padmanabhan, Thallam Veer .
JOURNAL OF ORAL IMPLANTOLOGY, 2013, 39 (06) :704-708