Three-phase active power filter based on current controlled voltage source inverter

被引:40
作者
El-Kholy, E. E. [1 ]
El-Sabbe, A.
Ei-Hefnawy, A.
Mharous, Hamdy M.
机构
[1] Menoufiya Univ, Dept Elect Engn, Fac Engn, Shibin Al Kawm, Egypt
[2] Int Stell Rolling Mill Co, Sadat, Egypt
关键词
active power filter; current control; artificial neural network;
D O I
10.1016/j.ijepes.2006.01.007
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a shunt active power filter to compensate reactive power and reduce the unwanted harmonics. A shunt active filter is realized employing three-phase voltage source inverter (VSI) bridge with common DC bus capacitor. The shunt active filter acts as a current source, which is connected in parallel with a nonlinear load and controlled to generate the required compensation currents. Two different proposed control methods for determining the reference compensating currents of the three-phase shunt active power filters based on proportional-integral (PI) controller and artificial neural network (ANN) are presented. Current controller based on modified hysteresis current controller is used to generate the firing pulses. The proposed system is implemented using a high speed Digital Signal Processor (DSP). Experimental and simulation results with different nonlinear loads are presented to confirm the validity of the proposed technique. (c) 2006 Elsevier Ltd. All rights reserved.
引用
收藏
页码:537 / 547
页数:11
相关论文
共 22 条
[1]   INSTANTANEOUS REACTIVE POWER COMPENSATORS COMPRISING SWITCHING DEVICES WITHOUT ENERGY-STORAGE COMPONENTS [J].
AKAGI, H ;
KANAZAWA, Y ;
NABAE, A .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1984, 20 (03) :625-630
[2]   Shunt-series active power filter for rectifiers AC and DC sides [J].
Barbosa, PG ;
Santisteban, JA ;
Watanabe, EH .
IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 1998, 145 (06) :577-584
[3]  
Bhattacharya S, 1995, IEEE IND APPLIC SOC, P2483, DOI 10.1109/IAS.1995.530619
[4]   Comparison of current control techniques for active filter applications [J].
Buso, S ;
Malesani, L ;
Mattavelli, P .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1998, 45 (05) :722-729
[5]   Design and fully digital control of parallel active filters for thyristor rectifiers to comply with IEC-1000-3-2 standards [J].
Buso, S ;
Malesani, L ;
Mattavelli, P ;
Veronese, R .
IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 1998, 34 (03) :508-517
[6]   An improved control algorithm of shunt active filter for voltage regulation, harmonic elimination, power-factor correction, and balancing of nonlinear loads [J].
Chandra, A ;
Singh, B ;
Singh, BN ;
Al-Haddad, K .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (03) :495-507
[7]   Line harmonics reduction in high-power systems using square-wave inverters-based dominant harmonic active filter [J].
Cheng, PT ;
Bhattacharya, S ;
Divan, DD .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 1999, 14 (02) :265-272
[8]   Control of a new active power filter using 3-D vector control [J].
Dastfan, A ;
Gosbell, VJ ;
Platt, D .
IEEE TRANSACTIONS ON POWER ELECTRONICS, 2000, 15 (01) :5-12
[9]   Control system for three-phase active power filter which simultaneously compensates power factor and unbalanced loads [J].
Dixon, JW ;
Garcia, JJ ;
Moran, L .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1995, 42 (06) :636-641
[10]   A series active power filter based on a sinusoidal current-controlled voltage-source inverter [J].
Dixon, JW ;
Venegas, G ;
Moran, LA .
IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 1997, 44 (05) :612-620