Biparametric versus multiparametric magnetic resonance imaging of the prostate: detection of clinically significant cancer in a perfect match group

被引:11
作者
Cho, Jungheum [1 ]
Ahn, Hyungwoo [1 ]
Hwang, Sung Il [1 ]
Lee, Hak Jong [1 ]
Choe, Gheeyoung [2 ]
Byun, Seok-Soo [3 ]
Hong, Sung Kyu [3 ]
机构
[1] Seoul Natl Univ, Bundang Hosp, Dept Radiol, 300 Gumi Dong, Seongnam Si 13620, Gyeonggi Do, South Korea
[2] Seoul Natl Univ, Bundang Hosp, Dept Pathol, Seongnam Si, Gyeonggi Do, South Korea
[3] Seoul Natl Univ, Bundang Hosp, Dept Urol, Seongnam Si, Gyeonggi Do, South Korea
关键词
Biparametric; Magnetic resonance imaging; Multiparametric; Prostate cancer; Prostate imaging reporting and data system; MRI; BIOPSY; RATIO; LOCALIZATION; EXTENSION; MEN;
D O I
10.1016/j.prnil.2019.12.004
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Biparametric (bp) magnetic resonance imaging (MRI) could be an alternative MRI for the detection of the clinically significant prostate cancer (csPCa). Purpose: To compare the accuracies of prostate cancer detection and localization between prebiopsy bpMRI and postbiopsy multiparametric MRI (mpMRI) taken on different days, using radical prostatectomy specimens as the reference standards. Material and methods: Data of 41 total consecutive patients who underwent the following examinations and procedures between September 2015 and March 2017 were collected: (1) magnetic resonancee and/or ultrasonography-guided biopsy after bpMRI; (2) postbiopsy mpMRI; and (3) radical prostatectomy with csPCa. Two radiologists scored suspected lesions on bpMRI and mpMRI independently using Prostate Imaging Reporting and Data System version 2. The diagnostic accuracy of detecting csPCa and the Dice similarity coefficient were obtained. Apparent diffusion coefficient (ADC) ratios were also obtained for quantitative comparison between bpMRI and mpMRI. Results: Diagnostic accuracies on bpMRI and mpMRI were 0.83 and 0.82 for reader 1; 0.80 and 0.82 for reader 2. There are no significantly different values of diagnostic sensitivities or specificities between the readers or between MRI protocols. Intra-observer Dice similarity coefficient was significantly lower in reader 2, compared to that in reader 1 between the two MRI protocols. The range of mean ADC ratio was 0.281-0.635. There was no statistically significant difference in the ADC ratio between bpMRI and mpMRI. Conclusions: Diagnostic performance of bpMRI without dynamic contrast enhancement MRI is not significantly different from mpMRI with dynamic contrast enhancement MRI in the detection of csPCa. (C) 2020 Asian Pacific Prostate Society, Published by Elsevier Korea LLC.
引用
收藏
页码:146 / 151
页数:6
相关论文
共 31 条
[1]  
[Anonymous], 2018, AJR AM J ROENTGENOL
[2]   Value of the Hemorrhage Exclusion Sign on T1-weighted Prostate MR Images for the Detection of Prostate Cancer [J].
Barrett, Tristan ;
Vargas, Hebert Alberto ;
Akin, Oguz ;
Goldman, Debra A. ;
Hricak, Hedvig .
RADIOLOGY, 2012, 263 (03) :751-757
[3]   Detection of Clinically Significant Prostate Cancer: Short Dual-Pulse Sequence versus Standard Multiparametric MR Imaging-A Multireader Study [J].
Barth, Borna K. ;
De Visschere, Pieter J. L. ;
Cornelius, Alexander ;
Nicolau, Carlos ;
Vargas, Hebert Alberto ;
Eberli, Daniel ;
Donati, Olivio F. .
RADIOLOGY, 2017, 284 (03) :725-736
[4]   Apparent diffusion coefficient ratio correlates significantly with prostate cancer gleason score at final pathology [J].
Boesen, Lars ;
Chabanova, Elizaveta ;
Logager, Vibeke ;
Balslev, Ingegerd ;
Thomsen, Henrik S. .
JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) :446-453
[5]   Apparent Diffusion Coefficient Value and Ratio as Noninvasive Potential Biomarkers to Predict Prostate Cancer Grading: Comparison With Prostate Biopsy and Radical Prostatectomy Specimen [J].
De Cobelli, Francesco ;
Ravelli, Silvia ;
Esposito, Antonio ;
Giganti, Francesco ;
Gallina, Andrea ;
Montorsi, Francesco ;
Del Maschio, Alessandro .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2015, 204 (03) :550-557
[6]   Dynamic contrast-enhanced imaging has limited added value over T2-weighted imaging and diffusion-weighted imaging when using PI-RADSv2 for diagnosis of clinically significant prostate cancer in patients with elevated PSA [J].
De Visschere, P. ;
Lumen, N. ;
Ost, P. ;
Decaestecker, K. ;
Pattyn, E. ;
Villeirs, G. .
CLINICAL RADIOLOGY, 2017, 72 (01) :23-32
[7]   Diagnostic accuracy of biparametric vs multiparametric MRI in clinically significant prostate cancer: Comparison between readers with different experience [J].
Di Campli, Eleonora ;
Pizzi, Andrea Delli ;
Seccia, Barbara ;
Cianci, Roberta ;
d'Annibale, Martina ;
Colasante, Antonella ;
Cinalli, Sebastiano ;
Castellan, Pietro ;
Navarra, Riccardo ;
Iantorno, Romina ;
Gabrielli, Daniela ;
Buffone, Angelica ;
Caulo, Massimo ;
Basilico, Raffaella .
EUROPEAN JOURNAL OF RADIOLOGY, 2018, 101 :17-23
[8]   MEASURES OF THE AMOUNT OF ECOLOGIC ASSOCIATION BETWEEN SPECIES [J].
DICE, LR .
ECOLOGY, 1945, 26 (03) :297-302
[9]   Combined Biparametric Prostate Magnetic Resonance Imaging and Prostate-specific Antigen in the Detection of Prostate Cancer: A Validation Study in a Biopsy-naive Patient Population [J].
Fascelli, Michele ;
Rais-Bahrami, Soroush ;
Sankineni, Sandeep ;
Brown, Anna M. ;
George, Arvin K. ;
Ho, Richard ;
Frye, Thomas ;
Kilchevsky, Amichai ;
Chelluri, Raju ;
Abboud, Steven ;
Siddiqui, M. Minhaj ;
Merino, Maria J. ;
Wood, Bradford J. ;
Choyke, Peter L. ;
Pinto, Peter A. ;
Turkbey, Baris .
UROLOGY, 2016, 88 :125-132
[10]   Prostate cancer detection with biparametric magnetic resonance imaging (bpMRI) by readers with different experience: performance and comparison with multiparametric (mpMRI) [J].
Gatti, Marco ;
Faletti, Riccardo ;
Calleris, Giorgio ;
Giglio, Jacopo ;
Berzovini, Claudio ;
Gentile, Francesco ;
Marra, Giancarlo ;
Misischi, Francesca ;
Molinaro, Luca ;
Bergamasco, Laura ;
Gontero, Paolo ;
Papotti, Mauro ;
Fonio, Paolo .
ABDOMINAL RADIOLOGY, 2019, 44 (05) :1883-1893