Radiation dose and image quality of computed tomography of the supra-aortic arteries: A comparison between single-source and dual-source CT Scanners

被引:12
|
作者
Saba, Luca [1 ]
di Martino, Michele [3 ]
Siotto, Paolo [2 ]
Anzidei, Michele [3 ]
Argiolas, Giovanni Maria [2 ]
Porcu, Michele [2 ]
Suri, Jasjit S. [4 ]
Wintermark, Max [5 ]
机构
[1] AOU, Dept Radiol, Cagliari Polo Monserrato Ss 554, I-09045 Cagliari, Italy
[2] Azienda Osped Brotzu, Dept Radiol, I-09100 Cagliari, Italy
[3] Univ Roma La Sapienza, Dept Radiol, Rome, Italy
[4] AtheroPoint TM, Monitoring & Diagnost Div, Roseville, CA USA
[5] Stanford Sch Med, Dept Neuroradiol, 291 Campus Dr, Stanford, CA 94305 USA
关键词
CTA; Radiation dose; CAROTID PLAQUE; ENERGY CT; ANGIOGRAPHY; STENOSIS; RISK; VOLUME; SIZE;
D O I
10.1016/j.neurad.2017.09.007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose. - The purpose of this work was to compare the image quality and radiation dose delivered to patients during computed tomography (CT) angiography (CTA) of the supra-aortic arteries using two single-source (SS) and two dual-energy (DE) CT scanners. Material and methods. - In this retrospective study, 120 patients who underwent CTA of supra-aortic arteries were studied using four different types of CT scanners: a sixteen and forty-detector-row SS and two DE CT scanners. Seventy milliters of contrast medium were injected at a flow rate of 4 mL/s using a power injector. For each patient the dose-length product (DLP), the volume computed tomography dose index (CDTlvol), the length of the scan and the effective dose (ED) were calculated. Qualitative and quantitative [image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)] image quality assessment was performed. Results. - A statistically significant lower value of the DE compared to the SS technology (P<0.0001) for the CDTI, DLP and ED was found, whereas we did not find any statistically significant difference between the four scanners for the measurements of the image noise, SNR and CNR. Conclusion. - DS CT scanners allow performing CTAs with a reduced dose compared to SS CT scanner with comparable image quality. (C) 2017 Published by Elsevier Masson SAS.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 50 条
  • [41] Carotid Plaque Analysis: Comparison of Dual-Source Computed Tomography (CT) Findings and Histopathological Correlation
    Das, M.
    Braunschweig, T.
    Muehlenbruch, G.
    Mahnken, A. H.
    Krings, T.
    Langer, S.
    Koeppel, T.
    Jacobs, M.
    Guenther, R. W.
    Mommertz, G.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 38 (01) : 14 - 19
  • [42] Single-source chest-abdomen-pelvis cancer staging on a third generation dual-source CT system: comparison of automated tube potential selection to second generation dual-source CT
    Park, Clara
    Gruber-Rouh, Tatjana
    Leithner, Doris
    Zierden, Amelie
    Albrecht, Mortiz H.
    Wichmann, Julian L.
    Bodelle, Boris
    Elsabaie, Mohamed
    Scholtz, Jan-Erik
    Kaup, Moritz
    Vogl, Thomas J.
    Beeres, Martin
    CANCER IMAGING, 2016, 16 : 1 - 7
  • [43] Dose performance and image quality: Dual source CT versus single source CT in cardiac CT angiography
    Wang, Min
    Qi, Heng-Tao
    Wang, Xi-Ming
    Wang, Tao
    Chen, Jiu-Hong
    Liu, Cheng
    EUROPEAN JOURNAL OF RADIOLOGY, 2009, 72 (03) : 396 - 400
  • [44] Image quality in dual-source multiphasic dynamic computed tomography of the abdomen: evaluating the effects of a low tube voltage (70 kVp) in combination with contrast dose reduction
    Miyoshi, Keisuke
    Onoda, Hideko
    Tanabe, Mashiro
    Nakao, Sei
    Higashi, Mayumi
    Iida, Etsushi
    Okada, Munemasa
    Furukawa, Matakazu
    Ito, Katsuyoshi
    ABDOMINAL RADIOLOGY, 2020, 45 (11) : 3755 - 3762
  • [45] Image quality and radiation dose of dual source high pitch computed tomography in pediatric congenital heart disease
    Kravchenko, Dmitrij
    Hart, Christopher
    Garbe, Stephan
    Luetkens, Julian A.
    Isaak, Alexander
    Mesropyan, Narine
    Vergnat, Mathieu
    Leyens, Judith
    Attenberger, Ulrike
    Kuetting, Daniel
    SCIENTIFIC REPORTS, 2022, 12 (01):
  • [46] Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition
    Ghadri, Jelena R.
    Kueest, Silke M.
    Goetti, Robert
    Fiechter, Michael
    Pazhenkottil, Aju P.
    Nkoulou, Rene N.
    Kuhn, Felix P.
    Pietsch, Carsten
    von Schulthess, Patrick
    Gaemperli, Oliver
    Templin, Christian
    Kaufmann, Philipp A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (05) : 1217 - 1225
  • [47] Dual-source cardiac computed tomography angiography (CCTA) in the follow-up of cardiac transplant: comparison of image quality and radiation dose using three different imaging protocols
    Beitzke, D.
    Berger-Kulemann, V.
    Schoepf, V.
    Unterhumer, S.
    Spitzer, E.
    Feuchtner, G. M.
    Gyoengyoesi, M.
    Uyanik-Uenal, K.
    Zuckermann, A.
    Loewe, C.
    Wolf, F.
    EUROPEAN RADIOLOGY, 2015, 25 (08) : 2310 - 2317
  • [48] Dual-source cardiac computed tomography angiography (CCTA) in the follow-up of cardiac transplant: comparison of image quality and radiation dose using three different imaging protocols
    D. Beitzke
    V. Berger-Kulemann
    V. Schöpf
    S. Unterhumer
    E. Spitzer
    G. M. Feuchtner
    M. Gyöngyösi
    K. Uyanik-Uenal
    A. Zuckermann
    C. Loewe
    F. Wolf
    European Radiology, 2015, 25 : 2310 - 2317
  • [49] Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition
    Jelena R. Ghadri
    Silke M. Küest
    Robert Goetti
    Michael Fiechter
    Aju P. Pazhenkottil
    Rene N. Nkoulou
    Felix P. Kuhn
    Carsten Pietsch
    Patrick von Schulthess
    Oliver Gaemperli
    Christian Templin
    Philipp A. Kaufmann
    The International Journal of Cardiovascular Imaging, 2012, 28 : 1217 - 1225
  • [50] Evaluation of image quality and radiation dose of thoracic and coronary dual-source CT in 110 infants with congenital heart disease
    Ben Saad, Moez
    Rohnean, Adela
    Sigal-Cinqualbre, Anne
    Adler, Ghazal
    Paul, Jean-Francois
    PEDIATRIC RADIOLOGY, 2009, 39 (07) : 668 - 676