Radiation dose and image quality of computed tomography of the supra-aortic arteries: A comparison between single-source and dual-source CT Scanners

被引:12
|
作者
Saba, Luca [1 ]
di Martino, Michele [3 ]
Siotto, Paolo [2 ]
Anzidei, Michele [3 ]
Argiolas, Giovanni Maria [2 ]
Porcu, Michele [2 ]
Suri, Jasjit S. [4 ]
Wintermark, Max [5 ]
机构
[1] AOU, Dept Radiol, Cagliari Polo Monserrato Ss 554, I-09045 Cagliari, Italy
[2] Azienda Osped Brotzu, Dept Radiol, I-09100 Cagliari, Italy
[3] Univ Roma La Sapienza, Dept Radiol, Rome, Italy
[4] AtheroPoint TM, Monitoring & Diagnost Div, Roseville, CA USA
[5] Stanford Sch Med, Dept Neuroradiol, 291 Campus Dr, Stanford, CA 94305 USA
关键词
CTA; Radiation dose; CAROTID PLAQUE; ENERGY CT; ANGIOGRAPHY; STENOSIS; RISK; VOLUME; SIZE;
D O I
10.1016/j.neurad.2017.09.007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose. - The purpose of this work was to compare the image quality and radiation dose delivered to patients during computed tomography (CT) angiography (CTA) of the supra-aortic arteries using two single-source (SS) and two dual-energy (DE) CT scanners. Material and methods. - In this retrospective study, 120 patients who underwent CTA of supra-aortic arteries were studied using four different types of CT scanners: a sixteen and forty-detector-row SS and two DE CT scanners. Seventy milliters of contrast medium were injected at a flow rate of 4 mL/s using a power injector. For each patient the dose-length product (DLP), the volume computed tomography dose index (CDTlvol), the length of the scan and the effective dose (ED) were calculated. Qualitative and quantitative [image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)] image quality assessment was performed. Results. - A statistically significant lower value of the DE compared to the SS technology (P<0.0001) for the CDTI, DLP and ED was found, whereas we did not find any statistically significant difference between the four scanners for the measurements of the image noise, SNR and CNR. Conclusion. - DS CT scanners allow performing CTAs with a reduced dose compared to SS CT scanner with comparable image quality. (C) 2017 Published by Elsevier Masson SAS.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 50 条
  • [31] Radiation exposure and image quality in staged low-dose protocols for coronary dual-source CT angiography: a randomized comparison
    Pflederer, Tobias
    Jakstat, Josy
    Marwan, Mohamed
    Schepis, Tiziano
    Bachmann, Sven
    Kuettner, Axel
    Anders, Katharina
    Lell, Michael
    Muschiol, Gerd
    Ropers, Dieter
    Daniel, Werner G.
    Achenbach, Stephan
    EUROPEAN RADIOLOGY, 2010, 20 (05) : 1197 - 1206
  • [32] Diagnostic accuracy and image quality of cardiac dual-source computed tomography in patients with arrhythmia
    Tsiflikas, Ilias
    Drosch, Tanja
    Brodoefel, Harald
    Thomas, Christoph
    Reimann, Anja
    Till, Alexander
    Nittka, Daniel
    Kopp, Andreas F.
    Schroeder, Stephen
    Heuschmid, Martin
    Burgstahler, Christof
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2010, 143 (01) : 79 - 85
  • [33] Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose
    Pinho, Daniella F.
    Kulkarni, Naveen M.
    Krishnaraj, Arun
    Kalva, Sanjeeva P.
    Sahani, Dushyant V.
    EUROPEAN RADIOLOGY, 2013, 23 (02) : 351 - 359
  • [34] Comparison of Aortic Valve Area Measured by Magnetic Resonance Imaging and Dual-Source Computed Tomography
    Bruder, O.
    Jochims, M.
    Hunold, P.
    Jensen, C.
    Forsting, M.
    Sabin, G. V.
    Barkhausen, J.
    Schlosser, T.
    ACTA RADIOLOGICA, 2009, 50 (06) : 645 - 651
  • [35] Comparison of Radiation Dose and Image Quality Between Split-Filter Twin Beam Dual-Energy Images and Single-Energy Images in Single-Source Contrast-Enhanced Chest Computed Tomography
    Zhou, Li-Na
    Zhao, Shi-Jun
    Wang, Ruo-Bing
    Wang, Ya-Wen
    Yang, Shou-Xin
    Wu, Ning
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2021, 45 (06) : 888 - 893
  • [36] Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose
    Daniella F. Pinho
    Naveen M. Kulkarni
    Arun Krishnaraj
    Sanjeeva P. Kalva
    Dushyant V. Sahani
    European Radiology, 2013, 23 : 351 - 359
  • [37] Effects of the Sn100 kVp Tube Voltage Mode on the Radiation Dose and Image Quality of Dual-Source Computed Tomography Pulmonary Angiography
    Zhang, Wei-Guo
    Liu, Jia-Ping
    Jia, Xiu-Qin
    Zhang, Ji-Yang
    Li, Xiang-Nan
    Yang, Qi
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2021, 14 : 1033 - 1039
  • [38] Dual-source CT Angiography in Aortic Stent Grafting: An in vitro Aorta Phantom Study of Image Noise and Radiation Dose
    Sun, Zhonghua
    Ng, Curtise
    ACADEMIC RADIOLOGY, 2010, 17 (07) : 884 - 893
  • [39] High-pitch non-gated scans on the second and third generation dual-source CT scanners: comparison of coronary image quality
    Lin, Cheng Ting
    Chu, Linda Chi Hang
    Zimmerman, Stefan Loy
    Fishman, Elliot K.
    CLINICAL IMAGING, 2020, 59 (01) : 45 - 49
  • [40] Radiation dose and image quality of high-pitch emergency abdominal CT in obese patients using third-generation dual-source CT (DSCT)
    Forbrig, Robert
    Ingrisch, Michael
    Stahl, Robert
    Winter, Katharina Stella
    Reiser, Maximilian
    Trumm, Christoph G.
    SCIENTIFIC REPORTS, 2019, 9 (1)