Radiation dose and image quality of computed tomography of the supra-aortic arteries: A comparison between single-source and dual-source CT Scanners

被引:12
|
作者
Saba, Luca [1 ]
di Martino, Michele [3 ]
Siotto, Paolo [2 ]
Anzidei, Michele [3 ]
Argiolas, Giovanni Maria [2 ]
Porcu, Michele [2 ]
Suri, Jasjit S. [4 ]
Wintermark, Max [5 ]
机构
[1] AOU, Dept Radiol, Cagliari Polo Monserrato Ss 554, I-09045 Cagliari, Italy
[2] Azienda Osped Brotzu, Dept Radiol, I-09100 Cagliari, Italy
[3] Univ Roma La Sapienza, Dept Radiol, Rome, Italy
[4] AtheroPoint TM, Monitoring & Diagnost Div, Roseville, CA USA
[5] Stanford Sch Med, Dept Neuroradiol, 291 Campus Dr, Stanford, CA 94305 USA
关键词
CTA; Radiation dose; CAROTID PLAQUE; ENERGY CT; ANGIOGRAPHY; STENOSIS; RISK; VOLUME; SIZE;
D O I
10.1016/j.neurad.2017.09.007
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Purpose. - The purpose of this work was to compare the image quality and radiation dose delivered to patients during computed tomography (CT) angiography (CTA) of the supra-aortic arteries using two single-source (SS) and two dual-energy (DE) CT scanners. Material and methods. - In this retrospective study, 120 patients who underwent CTA of supra-aortic arteries were studied using four different types of CT scanners: a sixteen and forty-detector-row SS and two DE CT scanners. Seventy milliters of contrast medium were injected at a flow rate of 4 mL/s using a power injector. For each patient the dose-length product (DLP), the volume computed tomography dose index (CDTlvol), the length of the scan and the effective dose (ED) were calculated. Qualitative and quantitative [image noise, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR)] image quality assessment was performed. Results. - A statistically significant lower value of the DE compared to the SS technology (P<0.0001) for the CDTI, DLP and ED was found, whereas we did not find any statistically significant difference between the four scanners for the measurements of the image noise, SNR and CNR. Conclusion. - DS CT scanners allow performing CTAs with a reduced dose compared to SS CT scanner with comparable image quality. (C) 2017 Published by Elsevier Masson SAS.
引用
收藏
页码:136 / 141
页数:6
相关论文
共 50 条
  • [1] High-pitch dual-source CT angiography of supra-aortic arteries: assessment of image quality and radiation dose
    Korn, A.
    Fenchel, M.
    Bender, B.
    Danz, S.
    Thomas, C.
    Ketelsen, D.
    Claussen, C. D.
    Moonis, G.
    Krauss, B.
    Heuschmid, M.
    Ernemann, U.
    Brodoefel, H.
    NEURORADIOLOGY, 2013, 55 (04) : 423 - 430
  • [2] High-pitch dual-source CT angiography of supra-aortic arteries: assessment of image quality and radiation dose
    A. Korn
    M. Fenchel
    B. Bender
    S. Danz
    C. Thomas
    D. Ketelsen
    C. D. Claussen
    G. Moonis
    B. Krauss
    M. Heuschmid
    U. Ernemann
    H. Brodoefel
    Neuroradiology, 2013, 55 : 423 - 430
  • [3] Image Quality Performance of Virtual Single-Source CT Using Dual-Source Computed Tomography
    Alikhani, Babak
    Werner, Martin
    Jamali, Leila
    Wacker, Frank
    Werncke, Thomas
    ACADEMIC RADIOLOGY, 2019, 26 (08) : 1095 - 1101
  • [4] Estimated radiation dose and image quality comparison of the scan protocols in dual-source computed tomography coronary angiography
    Karaarslan, Ercan
    Ulus, Sila
    Bavbek, Cengiz
    JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2013, 57 (04) : 407 - 414
  • [5] Coronary CT angiography with single-source and dual-source CT: Comparison of image quality and radiation dose between prospective ECG-triggered and retrospective ECG-gated protocols
    Sabarudin, Akmal
    Sun, Zhonghua
    Yusof, Ahmad Khairuddin Md
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (02) : 746 - 753
  • [6] Diagnosis of Pulmonary Artery Embolism: Comparison of Single-Source CT and 3rd Generation Dual-Source CT using a Dual-Energy Protocol Regarding Image Quality and Radiation Dose
    Petritsch, Bernhard
    Kosmala, Aleksander
    Gassenmaier, Tobias
    Weng, Andreas Max
    Veldhoen, Simon
    Kunz, Andreas Steven
    Bley, Thorsten Alexander
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2017, 189 (06): : 527 - 536
  • [7] Dual-Source Dual-Energy CT Angiography of the Supra-Aortic Arteries with Tin Filter: Impact of Tube Voltage Selection
    Korn, Andreas
    Bender, Benjamin
    Schabel, Christoph
    Bongers, Malte
    Ernemann, Ulrike
    Claussen, Claus
    Thomas, Christoph
    ACADEMIC RADIOLOGY, 2015, 22 (06) : 708 - 713
  • [8] Computed Tomography Angiography with a 192-slice Dual-source Computed Tomography System: Improvements in Image Quality and Radiation Dose
    Linsen, Philip V. M.
    Coenen, Adriaan
    Lubbers, Marisa M.
    Dijkshoorn, Marcel L.
    Ouhlous, Mohamed
    Nieman, Koen
    JOURNAL OF CLINICAL IMAGING SCIENCE, 2016, 6
  • [9] The ascending aortic image quality and the whole aortic radiation dose of high-pitch dual-source CT angiography
    Ying Liu
    Jian Xu
    Jian Li
    Jing Ren
    Hongtao Liu
    Junqing Xu
    Mengqi Wei
    Yuewen Hao
    Minwen Zheng
    Journal of Cardiothoracic Surgery, 8
  • [10] Acquisition time, radiation dose, subjective and objective image quality of dual-source CT scanners in acute pulmonary embolism: a comparative study
    Abdellatif, Waleed
    Esslinger, Eric
    Kobes, Kevin
    Wong, Amanda
    Powell, Jennifer
    Ali, Ismail Tawakol
    Andrews, Gordon
    Nicolaou, Savvas
    EUROPEAN RADIOLOGY, 2020, 30 (05) : 2712 - 2721