Multilayered particle-packed column: Evaluation and comparison with monolithic and core-shell particle columns for the determination of red azo dyes in Sequential Injection Chromatography

被引:10
作者
Chocholous, Petr [1 ]
Gil, Renato [2 ]
Acebal, Carolina C. [3 ]
Kubala, Viktor [1 ]
Satnsky, Dalibor [1 ]
Solich, Petr [1 ]
机构
[1] Charles Univ Prague, Fac Pharm Hradec Kralove, Dept Analyt Chem, Heyrovskeho 1203, Hradec Kralove 50005, Czech Republic
[2] Univ Porto, Fac Pharm, Dept Chem Sci, Oporto, Portugal
[3] Univ Nacl Sur, INQUISUR UNS CONICET, Dept Chem, Bahia Blanca, Buenos Aires, Argentina
关键词
azo dyes; columns comparison; multilayered particle column; sequential injection chromatography; SOLID-PHASE EXTRACTION; LIQUID-CHROMATOGRAPHY; GRADIENT ELUTION; SEPARATION; ACID;
D O I
10.1002/jssc.201601224
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A recently presented new type of "multilayered" organic-inorganic hybrid silica particle packed column YMC-Triart C-18 (50 mm x 4.6 mm, 5 mu m) was used for the development of a sequential injection chromatography method for determination of five azo dyes (Sudan I, Sudan II, Sudan III, Sudan orange G, and para red) in selected food seasonings. The use of a novel sorbent brings attractive features, reduced backpressure, and broader chemical stability together with high separation performance, which are discussed and compared with that of three types of columns typically used in medium-pressure flow chromatography techniques (classic monolithic, narrow monolithic, and core-shell particle columns). The separation was performed in gradient elution mode created by the zone mixing of two mobile phases (acetonitrile/water 90:10, 1.5 mL + acetonitrile/water 100:0, 2.3 mL) at a flow rate of 0.60 mL/min and time of analysis < 9.5 min. The spectrophotometric detection wavelengths were set to 400, 480, and 500 nm. The high performance of the developed method with multilayered particle column was well documented and the results indicate a broad capability of sequential injection chromatography.
引用
收藏
页码:1225 / 1233
页数:9
相关论文
共 19 条
[1]  
[Anonymous], 2015, EUROPEAN PHARMACOPOE
[2]   On-line hyphenation of solid-phase extraction to chromatographic separation of sulfonamides with fused-core columns in sequential injection chromatography [J].
Batista, Alex D. ;
Chocholous, Petr ;
Satinsky, Dalibor ;
Solich, Petr ;
Rocha, Fabio R. P. .
TALANTA, 2015, 133 :142-149
[3]   Expanding the separation capability of sequential injection chromatography: Determination of melamine in milk exploiting micellar medium and on-line sample preparation [J].
Batista, Alex D. ;
Nascimento, Carina F. ;
Melchert, Wanessa R. ;
Rocha, Fabio R. P. .
MICROCHEMICAL JOURNAL, 2014, 117 :106-110
[4]   Determination of pesticides fenoxycarb and permethrin by sequential injection chromatography using miniaturized monolithic column [J].
Chocholous, Petr ;
Satinsky, Dalibor ;
Sladkovsky, Radek ;
Pospisilova, Marie ;
Solich, Petr .
TALANTA, 2008, 77 (02) :566-570
[5]   A novel application of Onyx™ monolithic column for simultaneous determination of salicylic acid and triamcinolone acetonide by sequential injection chromatography [J].
Chocholous, Petr ;
Holik, Pavel ;
Satinsky, Dalibor ;
Solich, Petr .
TALANTA, 2007, 72 (02) :854-858
[6]   Enhanced capabilities of separation in Sequential Injection Chromatography - Fused-core particle column and its comparison with narrow-bore monolithic column [J].
Chocholous, Petr ;
Kosarova, Lucie ;
Satinsky, Dalibor ;
Sklenarova, Hana ;
Solich, Petr .
TALANTA, 2011, 85 (02) :1129-1134
[7]   Two-column Sequential Injection Chromatography-New approach for fast and effective analysis and its comparison with gradient elution chromatography [J].
Chocholous, Petr ;
Satinsky, Dalibor ;
Sklenarova, Hana ;
Solich, Petr .
ANALYTICA CHIMICA ACTA, 2010, 668 (01) :61-66
[8]   Multisyringe chromatography (MSC) using a monolithic column for the determination of sulphonated azo dyes [J].
Fernandez, Cristina ;
Larrechi, M. Soledad ;
Forteza, R. ;
Cerda, V. ;
Callao, M. Pilar .
TALANTA, 2010, 82 (01) :137-142
[9]   FUNDAMENTALS OF SINUSOIDAL FLOW SEQUENTIAL INJECTION SPECTROPHOTOMETRY [J].
GUBELI, T ;
CHRISTIAN, GD ;
RUZICKA, J .
ANALYTICAL CHEMISTRY, 1991, 63 (21) :2407-2413
[10]   GRADIENT ELUTION IN LIQUID-CHROMATOGRAPHY .11. INFLUENCE OF THE ADJUSTABLE GRADIENT PARAMETERS ON THE CHROMATOGRAPHIC BEHAVIOR OF SAMPLE COMPOUNDS [J].
JANDERA, P ;
CHURACEK, J .
JOURNAL OF CHROMATOGRAPHY, 1980, 192 (01) :1-18