Oral administration of iopentol (Imagopaque(R) 300 mg I/ml) a compared with amidotrizoate (Peritrast(R) 300 mg I/ml), both diluted to 2% (v/v), in imaging of the gastrointestinal tract in abdominal contrast enhanced CT - A clinical trial assessing patient tolerance, distribution of contrast medium and Hounsfield unit measurements

被引:7
作者
Friedrich, JM
Skinningsrud, K
Welter, C
Eide, H
Merkle, E
机构
[1] NYCOMED IMAGING AS,CLIN R&D,N-0401 OSLO,NORWAY
[2] UNIV KLIN ESELSBERG,RONTGENDIAGNOST ABT,RADIOL KLIN,D-89081 ULM,GERMANY
关键词
computer tomography; oral contrast medium; iopentol; amidotrizoate;
D O I
10.1007/PL00006881
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The aim of the trial was to evaluate and compare the safety and efficacy of iopentol (Imagopaque(R), Nycomed Imaging AS, Oslo, Norway) and amidotrizoate (Peritrast(R), Kohler Pharma, Alsbach, Germany), both 300 mg I/ml initially, but diluted to 2% (v/v) and administered orally Sixty-four and 65 patients were included in the respective contrast medium groups. Portions of contrast medium, totally 1.51, were taken every 15 min during the hour before the examination. A standard radiological procedure for abdominal CT was followed. Nine percent of the patients in each group experienced adverse events which were possibly contrast medium related. Taste acceptance was comparable in the two groups. Except for the stomach, radiographic efficacy was satisfactory all intestinal segments. The difference in density in the proximal small bowel (main parameter) achieved with the media was not significant (p = 0.33), nor was that as regards image homogeneity (contrast distribution). In conclusion, iopentol is well suited for oral contrast enhancement of the gastrointestinal tract in abdominal computed tomography.
引用
收藏
页码:S140 / S144
页数:5
相关论文
共 17 条
[1]  
AAKHUS T, 1990, EXCERPTA MED INT C S, V909, P9
[2]  
ANDREW E, 1990, EXCERPTA MED INT C S, V909, P189
[3]  
*CPMP WORK PART EF, 1990, PHARMACOL TOXICOL, V67, P361
[4]   EVALUATION OF GASTROMIRO FOR BOWEL OPACIFICATION DURING COMPUTED-TOMOGRAPHY - COMPARISON WITH DIATRIZOATE AND BARIUM-SULFATE [J].
DOYLE, GJ ;
ODONNELL, SC ;
MCDONALD, JR ;
MURTHY, LNS ;
KEIR, MJ ;
WRIGHT, AR .
BRITISH JOURNAL OF RADIOLOGY, 1993, 66 (788) :681-684
[5]  
EGGLI KD, 1992, CLIN PEDIATR, V31, P554, DOI 10.1177/000992289203100908
[6]  
Friedrich J M, 1991, Rontgenpraxis, V44, P35
[7]   ADVERSE REACTIONS TO IONIC AND NONIONIC CONTRAST-MEDIA - A REPORT FROM THE JAPANESE-COMMITTEE-ON-THE-SAFETY-OF-CONTRAST MEDIA [J].
KATAYAMA, H ;
YAMAGUCHI, K ;
KOZUKA, T ;
TAKASHIMA, T ;
SEEZ, P ;
MATSUURA, K .
RADIOLOGY, 1990, 175 (03) :621-628
[8]  
KOLBENSTVEDT A, 1990, EXCERPTA MED INT C S, V909, P33
[9]   INTESTINAL FOLLOW-THROUGH EXAMINATIONS WITH IOHEXOL AND IOPENTOL - PERMEABILITY ALTERATIONS AND EFFICACY IN PATIENTS WITH SMALL-BOWEL OBSTRUCTION [J].
LAERUM, F ;
STORDAHL, A ;
SOLHEIM, KE ;
HAUGSTVEDT, JR ;
ROALD, HE ;
SKINNINGSRUD, K .
INVESTIGATIVE RADIOLOGY, 1991, 26 :S177-S181
[10]   ORAL CONTRAST-MEDIA IN CT OF THE ABDOMEN - IOHEXOL OF DIFFERENT CONCENTRATIONS AS A GASTROINTESTINAL CONTRAST-MEDIUM [J].
LONNEMARK, M ;
MAGNUSSON, A .
ACTA RADIOLOGICA, 1995, 36 (04) :396-398