Dynamic integrated method based on regression and averages, applied to estimate the thermal parameters of a room in an occupied office building in Madrid

被引:30
作者
Castillo, L. [1 ]
Enriquez, R. [1 ]
Jimenez, M. J. [1 ]
Heras, M. R. [1 ]
机构
[1] CIEMAT, Energy Efficiency Bldg R&D Unit, E-28040 Madrid, Spain
关键词
Building energy; Thermal parameters; Outdoor testing; Performance indicators; System identification; Occupancy; CONTINUOUS-TIME MODELS;
D O I
10.1016/j.enbuild.2014.06.039
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
A room facing north in a fully monitored office building located in Madrid (Spain) has been studied. Data corresponding to a period of more than two years, recorded while the building was regularly used, have been employed. A regression analysis method based on averages has been applied. Although the used equation is analogous to the steady state, dynamic features of the test have been considered. A dynamic energy balance equation is first stated. Then this equation is integrated for a time interval long enough to make the accumulation term much lower than the other terms. Finally averages are used to estimate integrals. The minimum integration period that allows this simplification has been identified, studying integration periods from 1 to 20 days. It is concluded that integration period and variables needed depend on test conditions and the building. Daily averages are insufficient for this analysis in these test conditions. Heat supplied by the HVAC system was modelled avoiding flow measurements. Suggested terms including occupancy and door status improve the model remarkably. A spread in the Overall Heat Transmission Coefficient (UA) estimated under 10%, was found for a 7-day integration period. This narrow interval allows to hand this parameter as intrinsic. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:337 / 362
页数:26
相关论文
共 26 条
[1]  
[Anonymous], 98691994 ISO
[2]   A pseudo dynamic analysis tool for thermal certification of dwellings [J].
Bloem, JJ ;
Martin, S .
ENERGY AND BUILDINGS, 2001, 33 (03) :207-212
[3]  
IEA ECBCS, ANN 58 REL BUILD EN
[4]   Estimation of building component UA and gA from outdoor tests in warm and moderate weather conditions [J].
Jimenez, M. J. ;
Porcar, B. ;
Heras, M. R. .
SOLAR ENERGY, 2008, 82 (07) :573-587
[5]   Estimation of non-linear continuous time models for the heat exchange dynamics of building integrated photovoltaic modules [J].
Jimenez, M. J. ;
Madsen, H. ;
Bloem, J. J. ;
Dammann, B. .
ENERGY AND BUILDINGS, 2008, 40 (02) :157-167
[6]   Models for describing the thermal characteristics of building components [J].
Jimenez, M. J. ;
Madsen, H. .
BUILDING AND ENVIRONMENT, 2008, 43 (02) :152-162
[7]  
Jimenez M.J, 2010, 1 C ARQ BIOCL FRIO S
[8]   ESTIMATION OF CONTINUOUS-TIME MODELS FOR THE HEAT DYNAMICS OF A BUILDING [J].
MADSEN, H ;
HOLST, J .
ENERGY AND BUILDINGS, 1995, 22 (01) :67-79
[9]  
Modera M.P., 1985, BUILDING APPL HEAT F, V885, P203
[10]   Setting up and validating a complex model for a simple homogeneous wall [J].
Naveros, I. ;
Bacher, P. ;
Ruiz, D. P. ;
Jimenez, M. J. ;
Madsen, H. .
ENERGY AND BUILDINGS, 2014, 70 :303-317