Autofocusing and edge detection schemes in cell volume measurements with quantitative phase microscopy

被引:57
作者
Lee, Seungrag [1 ]
Lee, Ji Yong [1 ]
Yang, Wenzhong [1 ]
Kim, Dug Young [1 ]
机构
[1] Gwangju Inst Sci & Technol, Dept Informat & Commun, Kwangju 500712, South Korea
关键词
DIFFRACTION PHASE; REFRACTIVE-INDEX; LIVING CELLS; DYNAMICS;
D O I
10.1364/OE.17.006476
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
We have proposed and demonstrated a very sensitive volume measurement scheme for a live cell with a quantitative phase microscopy (QPM) utilizing auto-focusing and numerical edge detection schemes. An auto-focusing technique with two different focus measures is applied to find the focus dependent errors in our live cell volume measurement system. The volume of a polystyrene bead sample with 3 mu m diameter has been measured for the validity test of our proposed method. We have shown that a small displacement of an object from its focusing position can cause a large volume error. A numerical edge detection technique is also used to accurately resolve the boundary between a cell and its suspension medium. We have applied this method to effectively suppress errors by the surrounding medium of a single red blood cell (RBC). (C) 2009 Optical Society of America
引用
收藏
页码:6476 / 6486
页数:11
相关论文
共 25 条
[1]   Single-cell volume estimation by three-dimensional wide-field microscopy applied to astroglial primary cultures [J].
Allansson, L ;
Khatibi, S ;
Gustavsson, T ;
Blomstrand, F ;
Olsson, T ;
Hansson, E .
JOURNAL OF NEUROSCIENCE METHODS, 1999, 93 (01) :1-11
[2]   FREQUENCY SPECTRUM OF FLICKER PHENOMENON IN ERYTHROCYTES [J].
BROCHARD, F ;
LENNON, JF .
JOURNAL DE PHYSIQUE, 1975, 36 (11) :1035-1047
[4]   Single cell volume measurement by quantitative phase microscopy (QPM): A case study of erythrocyte morphology [J].
Curl, Claire L. ;
Bellair, Catherine J. ;
Harris, Peter J. ;
Allman, Brendan E. ;
Roberts, Ann ;
Nugent, Keith A. ;
Delbridge, Lea M. D. .
CELLULAR PHYSIOLOGY AND BIOCHEMISTRY, 2006, 17 (5-6) :193-200
[5]   Imaging voltage-dependent cell motions with heterodyne Mach-Zehnder phase microscopy [J].
Fang-Yen, Christopher ;
Oh, Seungeun ;
Park, Yongkeun ;
Choi, Wonshik ;
Song, Sen ;
Seung, H. Sebastian ;
Dasari, Ramachandra R. ;
Feld, Michael S. .
OPTICS LETTERS, 2007, 32 (11) :1572-1574
[6]   Plasma membrane water permeability of cultured cells and epithelia measured by light microscopy with spatial filtering [J].
Farinas, J ;
Kneen, M ;
Moore, M ;
Verkman, AS .
JOURNAL OF GENERAL PHYSIOLOGY, 1997, 110 (03) :283-296
[7]   A COMPARISON OF DIFFERENT FOCUS FUNCTIONS FOR USE IN AUTOFOCUS ALGORITHMS [J].
GROEN, FCA ;
YOUNG, IT ;
LIGTHART, G .
CYTOMETRY, 1985, 6 (02) :81-91
[8]   Single scattering by red blood cells [J].
Hammer, M ;
Schweitzer, D ;
Michel, B ;
Thamm, E ;
Kolb, A .
APPLIED OPTICS, 1998, 37 (31) :7410-7418
[9]   PH, MORPHOLOGY, AND DIFFUSION IN LATERAL INTERCELLULAR SPACES OF EPITHELIAL-CELL MONOLAYERS [J].
HARRIS, PJ ;
CHATTON, JY ;
TRAN, PH ;
BUNGAY, PM ;
SPRING, KR .
AMERICAN JOURNAL OF PHYSIOLOGY, 1994, 266 (01) :C73-C80
[10]   Hilbert phase microscopy for investigating fast dynamics in transparent systems [J].
Ikeda, T ;
Popescu, G ;
Dasari, RR ;
Feld, MS .
OPTICS LETTERS, 2005, 30 (10) :1165-1167