The origin of Korotkoff sounds and the accuracy of auscultatory blood pressure measurements

被引:51
作者
Babbs, Charles F. [1 ]
机构
[1] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
关键词
Biomechanics; diastolic dilemma; muffling; sphygmomanometry; HUMAN BRACHIAL-ARTERY; WALL THICKNESS; MERCURY SPHYGMOMANOMETRY; VISCOELASTIC PROPERTIES; FLEXIBLE TUBES; RISK-FACTORS; REPRODUCIBILITY; CHILDREN; DEVICES; MODEL;
D O I
10.1016/j.jash.2015.09.011
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
This study explores the hypothesis that the sharper, high frequency Korotkoff sounds come from resonant motion of the arterial wall, which begins after the artery transitions from a buckled state to an expanding state. The motions of one mass, two nonlinear springs, and one damper, driven by transmural pressure under the cuff, are used to model and compute the Korotkoff sounds according to principles of classical Newtonian physics. The natural resonance of this spring-mass-damper system provides a concise, yet rigorous, explanation for the origin of Korotkoff sounds. Fundamentally, wall stretching in expansion requires more force than wall bending in buckling. At cuff pressures between systolic and diastolic arterial pressure, audible vibrations (>40 Hz) occur during early expansion of the artery wall beyond its zero pressure radius after the outward moving mass of tissue experiences sudden deceleration, caused by the discontinuity in stiffness between bucked and expanded states. The idealized spring-mass-damper model faithfully reproduces the time-domain waveforms of actual Korotkoff sounds in humans. Appearance of arterial sounds occurs at or just above the level of systolic pressure. Disappearance of arterial sounds occurs at or just above the level of diastolic pressure. Muffling of the sounds is explained by increased resistance of the artery to collapse, caused by downstream venous engorgement. A simple analytical model can define the physical origin of Korotkoff sounds, suggesting improved mechanical or electronic filters for their selective detection and confirming the disappearance of the Korotkoff sounds as the optimal diastolic end point. (c) 2015 American Society of Hypertension. All rights reserved.
引用
收藏
页码:935 / 950
页数:16
相关论文
共 47 条
[1]  
[Anonymous], 1988, Biomechanics: Mechanical Properties of Living Tissues, DOI DOI 10.1115/1.3138285
[2]   In vivo human brachial artery elastic mechanics - Effects of smooth muscle relaxation [J].
Bank, AJ ;
Kaiser, DR ;
Rajala, S ;
Cheng, A .
CIRCULATION, 1999, 100 (01) :41-47
[3]   Modeling of the deformation of flexible tubes using a single law: Application to veins of the lower limb in man [J].
Bassez, S ;
Flaud, P ;
Chauveau, M .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2001, 123 (01) :58-65
[4]  
BEKESY GEORG v., 1949, JOUR ACOUSTICAL SOC AMER, V21, P233
[5]  
Bergel DH, 1960, VISCOELASTIC PROPERT, P250
[7]   A MATHEMATICAL-MODEL OF UNSTEADY COLLAPSIBLE TUBE BEHAVIOR [J].
BERTRAM, CD ;
PEDLEY, TJ .
JOURNAL OF BIOMECHANICS, 1982, 15 (01) :39-50
[8]   Flow-mediated dilation in human brachial artery after different circulatory occlusion conditions [J].
Betik, AC ;
Luckham, VB ;
Hughson, RL .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2004, 286 (01) :H442-H448
[9]  
Boron W.F., 2005, MED PHYSL
[10]   CRITERION FOR DIASTOLIC PRESSURE - REVOLUTION AND COUNTERREVOLUTION [J].
BURTON, AC .
CIRCULATION, 1967, 36 (06) :805-&