Printability of calcium phosphate: Calcium sulfate powders for the application of tissue engineered bone scaffolds using the 3D printing technique

被引:174
作者
Zhou, Zuoxin [1 ]
Buchanan, Fraser [1 ]
Mitchell, Christina [2 ]
Dunne, Nicholas [1 ]
机构
[1] Queens Univ Belfast, Sch Mech & Aerosp Engn, Belfast BT9 5AH, Antrim, North Ireland
[2] Queens Univ Belfast, Sch Med Dent & Biomed Sci, Belfast BT9 7BL, Antrim, North Ireland
来源
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS | 2014年 / 38卷
关键词
Three-dimensional printing (3DP); Calcium phosphate; Calcium sulfate; Tissue engineering; Particle size; Drop penetration; HYDROXYAPATITE; DEFECTS; GRAFT;
D O I
10.1016/j.msec.2014.01.027
中图分类号
TB3 [工程材料学]; R318.08 [生物材料学];
学科分类号
0805 ; 080501 ; 080502 ;
摘要
In this study, calcium phosphate (CaP) powders were blended with a three-dimensional printing (3DP) calcium sulfate (CaSO4)-based powder and the resulting composite powders were printed with a water-based binder using the 3DP technology. Application of a water-based binder ensured the manufacture of CaP:CaSO4 constructs on a reliable and repeatable basis, without long term damage of the printhead. Printability of CaP:CaSO4 powders was quantitatively assessed by investigating the key 3DP process parameters, i.e. in-process powder bed packing, drop penetration behavior and the quality of printed solid constructs. Effects of particle size, CaP:CaSO4 ratio and CaP powder type on the 3DP process were considered. The drop penetration technique was used to reliably identify powder formulations that could be potentially used for the application of tissue engineered bone scaffolds using the 3DP technique. Significant improvements (p < 0.05) in the 3DP process parameters were found for CaP (30-110 mu m):CaSO4 powders compared to CaP (<20 mu m):CaSO4 powders. Higher compressive strength was obtained for the powders with the higher CaP:CaSO4 ratio. Hydroxyapatite (HA):CaSO4 powders showed better results than beta-tricalcium phosphate (beta-TCP):CaSO4 powders. Solid and porous constructs were manufactured using the 3DP technique from the optimized CaP:CaSO4 powder formulations. High-quality printed constructs were manufactured, which exhibited appropriate green compressive strength and a high level of printing accuracy. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 47 条
[1]  
[Anonymous], 105453 ISO
[2]  
[Anonymous], 2009, TSINGHUA SCI TECHNOL, DOI DOI 10.1016/S1007-0214(09)70062-8
[3]   3D printing of bone substitute implants using calcium phosphate and bioactive glasses [J].
Bergmann, Christian ;
Lindner, Markus ;
Zhang, Wen ;
Koczur, Karolina ;
Kirsten, Armin ;
Telle, Rainer ;
Fischer, Horst .
JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2010, 30 (12) :2563-2567
[4]   Treatment of nonunions and osseous defects with bone graft and calcium sulfate [J].
Borrelli, J ;
Prickett, WD ;
Ricci, WM .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2003, (411) :245-254
[5]   Structural and material approaches to bone tissue engineering in powder-based three-dimensional printing [J].
Butscher, A. ;
Bohner, M. ;
Hofmann, S. ;
Gauckler, L. ;
Mueller, R. .
ACTA BIOMATERIALIA, 2011, 7 (03) :907-920
[6]   Printability of calcium phosphate powders for three-dimensional printing of tissue engineering scaffolds [J].
Butscher, Andre ;
Bohner, Marc ;
Roth, Christian ;
Ernstberger, Annika ;
Heuberger, Roman ;
Doebelin, Nicola ;
von Rohr, Philipp Rudolf ;
Mueller, Ralph .
ACTA BIOMATERIALIA, 2012, 8 (01) :373-385
[7]   3D printing of hydroxyapatite: Effect of binder concentration in pre-coated particle on part strength [J].
Chumnanklang, R. ;
Panyathanmaporn, T. ;
Sitthiseripratip, K. ;
Suwanprateeb, J. .
MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2007, 27 (04) :914-921
[8]  
COETZEE AS, 1980, ARCH OTOLARYNGOL, V106, P405
[9]  
Dunne N., 2008, ACTA ORTHOP, V78, P774
[10]   Phase evolution during the low temperature formation of calcium-deficient hydroxyapatite-gypsum composites [J].
Greish, Yaser E. .
CERAMICS INTERNATIONAL, 2011, 37 (05) :1493-1500