Microsomal cytochrome P450-3A4 (CYP3A4) nanobiosensor for the determination of 2,4-dichlorophenol-An endocrine disruptor compound

被引:33
作者
Hendricks, Nicolette R. [1 ]
Waryo, Tesfaye T. [1 ]
Arotiba, Omotayo [1 ]
Jahed, Nazeem [1 ]
Baker, Priscilla G. L. [1 ]
Iwuoha, Emmanuel I. [1 ]
机构
[1] Univ Western Cape, SensorLab, Dept Chem, ZA-7535 Cape Town, South Africa
关键词
Biosensors; Cytochrome P450-3A4; Detection of 2,4-dichlorophenol; Electrochemical sensors; Endocrine disruptors; DRIVEN OMEGA-HYDROXYLATION; DIRECT ELECTRON-TRANSFER; HORSERADISH-PEROXIDASE; AMPEROMETRIC BIOSENSOR; DRUG-METABOLISM; FILMS; 3A4; SURFACTANTS; MEDIATOR; REACTIVITIES;
D O I
10.1016/j.electacta.2008.09.073
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
Cytochrome P450-3A4 (CYP3A4) is a monooxygenase enzyme that plays a major role in the detoxification of bioactive compounds and hydrophobic xenobiotics ( e. g. medicines, drugs, environmental pollutants, food supplements and steroids). Physiologically the monooxygenation reactions of this class II, microsomal, b-type heme enzyme, usually requires cytochrome P450 reductase, NADPH. A novel CYP3A4 biosensor system that essentially simplified the enzymatic redox processes by allowing electron transfer between the electrode and the enzyme redox centre to occur, without any need for the physiological redox partners, was developed for the detection of 2,4-dichlorophenol (2,4-DCP), a priority environmental pollutant and an endocrine disruptor. The biosensor, GC/Naf-Co(Sep)(3+)/CYP3A4/Naf, was constructed by encapsulating CYP3A4 in a Nafion-cobalt (III) sepulchrate (Naf-Co(Sep)(3+)) composite film on a glassy carbon (GC) electrode. The responses of the biosensor to 2,4-dichlorophenol, erythromycin (CYP3A4 native substrate) and ketoconazole (CYP 3A4 natural inhibitor) were studied by cyclic and square wave voltammetric techniques. The detection limit (DL) of the biosensor for 2,4-dichlorophenol was 0.043 mu gL(-1), which is by an order of magnitude lower than the EU limit (0.3 mu gL(-1)) for any pesticide compound in ground water. The biosensor's DL is lower than the U. S. Environmental Protection Agency's drinking water equivalent level (DWEL) value for 2,4-DCP, which is 2 mu gL(-1). (C) 2008 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1925 / 1931
页数:7
相关论文
共 43 条
[1]   Cytochrome P450 biosensors - a review [J].
Bistolas, N ;
Wollenberger, U ;
Jung, C ;
Scheller, FW .
BIOSENSORS & BIOELECTRONICS, 2005, 20 (12) :2408-2423
[2]   Preparation, characterization and application of alkanethiol self-assembled monolayers modified with tetrathiafulvalene and glucose oxidase at a gold disk electrode [J].
Campuzano, S ;
Gálvez, R ;
Pedero, M ;
de Villena, FJM ;
Pingarrón, JM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2002, 526 (1-2) :92-100
[3]   The ferrous-dioxygen intermediate in human cytochrome P450 3A4 - Substrate dependence of formation and decay kinetics [J].
Denisov, Ilia G. ;
Grinkova, Yelena V. ;
Baas, Bradley J. ;
Sligar, Stephen G. .
JOURNAL OF BIOLOGICAL CHEMISTRY, 2006, 281 (33) :23313-23318
[4]   Cyclic voltammetry of [Co(sep)](3+) incorporated in nafion polymer films on glassy carbon electrodes and ultramicroelectrodes [J].
Dewald, HD ;
Chen, J .
MICROCHEMICAL JOURNAL, 1997, 56 (02) :197-206
[5]   Strategies and molecular probes to investigate the role of cytochrome P450 in drug metabolism -: Focus on in vitro studies [J].
Donato, MT ;
Castell, JV .
CLINICAL PHARMACOKINETICS, 2003, 42 (02) :153-178
[6]  
EGGINS BR, 2003, CHEM SENSORS BIOSENS, P78
[7]  
*EPA, 2003, 604 EPA
[8]   ELECTROCATALYTICALLY DRIVEN OMEGA-HYDROXYLATION OF FATTY-ACIDS USING CYTOCHROME-P450 4A1 [J].
FAULKNER, KM ;
SHET, MS ;
FISHER, CW ;
ESTABROOK, RW .
PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA, 1995, 92 (17) :7705-7709
[9]  
FLEMMING BD, 2003, EUROPEAN J BIOCH, V270, P4083
[10]   A glucose biosensor using methyl viologen redox mediator on carbon film electrodes [J].
Ghica, ME ;
Brett, CMA .
ANALYTICA CHIMICA ACTA, 2005, 532 (02) :145-151