Heart rate monitoring and therapeutic devices: A wavelet transform based approach for the modeling and classification of congestive heart failure

被引:48
作者
Kumar, Ashish [1 ]
Komaragiri, Rama [1 ]
Kumar, Manjeet [1 ]
机构
[1] Bennett Univ, Dept Elect & Commun Engn, Greater Noida 201310, Uttar Pradesh, India
关键词
Heart rate monitoring; Congestive heart failure; Electrocardiogram; Biorthogonal wavelet transform; Wavelet filter bank; QRS DETECTION; DATA-COMPRESSION; ECG; DESIGN; FILTER; SIGNAL; ALGORITHM; IMPLEMENTATION; DETECTOR; SCHEME;
D O I
10.1016/j.isatra.2018.05.003
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Heart rate monitoring and therapeutic devices include real-time sensing capabilities reflecting the state of the heart. Current circuitry can be interpreted as a cardiac electrical signal compression algorithm representing the time signal information into a single event description of the cardiac activity. It is observed that some detection techniques developed for ECG signal detection like artificial neural network, genetic algorithm, Hilbert transform, hidden Markov model are some sophisticated algorithms which provide suitable results but their implementation on a silicon chip is very complicated. Due to less complexity and high performance, wavelet transform based approaches are widely used. In this paper, after a thorough analysis of various wavelet transforms, it is found that Biorthogonal wavelet transform is best suited to detect ECG signal's QRS complex. The main steps involved in ECG detection process consist of de-noising and locating different ECG peaks using adaptive slope prediction thresholding. Furthermore, the significant challenges involved in the wireless transmission of ECG data are data conversion and power consumption. As medical regulatory boards demand a lossless compression technique, lossless compression technique with a high bit compression ratio is highly required. Furthermore, in this work, LZMA based ECG data compression technique is proposed. The proposed methodology achieves the highest signal to noise ratio, and lowest root mean square error. Also, the proposed ECG detection technique is capable of distinguishing accurately between healthy, myocardial infarction, congestive heart failure and coronary artery disease patients with a detection accuracy, sensitivity, specificity, and error of 99.92%, 99.94%, 99.92% and 0.0013, respectively. The use of LZMA data compression of ECG data achieves a high compression ratio of 18.84. The advantages and effectiveness of the proposed algorithm are verified by comparing with the existing methods.
引用
收藏
页码:239 / 250
页数:12
相关论文
共 62 条
[11]   FPGA-oriented HW/SW implementation of ECG beat detection and classification algorithm [J].
Cvikl, Matej ;
Zemva, Andrej .
DIGITAL SIGNAL PROCESSING, 2010, 20 (01) :238-248
[12]   A Joint QRS Detection and Data Compression Scheme for Wearable Sensors [J].
Deepu, C. J. ;
Lian, Y. .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2015, 62 (01) :165-175
[13]  
Deepu C. J., 2010, Proceedings of the Fifth IEEE International Workshop on Electronic Design, Test and Application (DELTA 2010), P225, DOI 10.1109/DELTA.2010.43
[14]   A 3-Lead ECG-on-Chip with QRS Detection and Lossless Compression for Wireless Sensors [J].
Deepu, Chacko John ;
Zhang, Xiaoyang ;
Heng, Chun Huat ;
Lian, Yong .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS II-EXPRESS BRIEFS, 2016, 63 (12) :1151-1155
[15]  
Dinh HAN, 2001, P ANN INT IEEE EMBS, V23, P1883, DOI [10.1109/IEMBS.2001.1020593, 10.1007/BF03178366]
[16]   A Patient-Adaptive Profiling Scheme for ECG Beat Classification [J].
Faezipour, Miad ;
Saeed, Adnan ;
Bulusu, Suma Chandrika ;
Nourani, Mehrdad ;
Minn, Hlaing ;
Tamil, Lakshman .
IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2010, 14 (05) :1153-1165
[17]   A COMPARISON OF THE NOISE SENSITIVITY OF 9 QRS DETECTION ALGORITHMS [J].
FRIESEN, GM ;
JANNETT, TC ;
JADALLAH, MA ;
YATES, SL ;
QUINT, SR ;
NAGLE, HT .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (01) :85-98
[18]   QUANTITATIVE INVESTIGATION OF QRS DETECTION RULES USING THE MIT/BIH ARRHYTHMIA DATABASE [J].
HAMILTON, PS ;
TOMPKINS, WJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1986, 33 (12) :1157-1165
[19]  
Hesar HD, 2007, IEEE J BIOMED HEALTH, V21, P635
[20]   Real-time detection of pathological cardiac events in the electrocardiogram [J].
Iliev, Ivo ;
Krasteva, Vessela ;
Tabakov, Serafim .
PHYSIOLOGICAL MEASUREMENT, 2007, 28 (03) :259-276