Stability Analysis and Efficiency Optimization of an Inductive Power Transfer System With a Constant Power Load

被引:3
|
作者
Scher, Aaron D. [1 ]
Kosik, Michal [2 ]
Pham, Peter [3 ]
Costinett, Daniel [3 ]
Hossain, Eklas [1 ]
机构
[1] Oregon Inst Technol, Dept Elect Engn & Renewable Energy, Klamath Falls, OR 97601 USA
[2] Czech Tech Univ, Dept Elect Drives & Tract, Prague 16627, Czech Republic
[3] Univ Tennessee, Coll Engn Elect Engn & Comp Sci, Knoxville, TN 37996 USA
来源
IEEE ACCESS | 2020年 / 8卷
关键词
Stability criteria; Power system stability; Resonant frequency; Impedance; Steady-state; Inverters; Resistance; Constant power load (CPL); constant resistance load (CRL); power transfer; resonance; series-series compensated inductive power transfer (SSIPT); IMPEDANCE; CONVERTERS; INSTABILITY; FREQUENCY; CRITERION;
D O I
10.1109/ACCESS.2020.3039181
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Series-series compensated inductive power transfer (SSIPT) systems have been widely studied and characterized for constant resistance loads (CRLs) and constant voltage loads (CVLs), but much less so for constant power loads (CPLs), although CPLs have numerous applications. In this work, we address some of the fundamental knowledge gaps for SSIPT/CPL systems that we believe have not been fully explored in the literature. First, we apply Middlebrook's stability criterion to derive a closed-form impedance-based stability condition for SSIPT/CPL systems. The derivation of the equilibrium solution is based on small-signal analysis and we show its consistency with intuitive results from perturbation-based arguments. Second, we show that the power transfer efficiency is minimum at the resonant frequency of the primary resonator. Third, the stability criterion is used to develop a straightforward approach for finding the operating frequency and input voltage that achieves near-maximum power transfer efficiency. This solution is useful as a starting point for a more meticulous parameter sweep to find the optimum input voltage and frequency values. Our analytical results are validated by performing frequency sweep measurements with two SSIPT experimental setups - one tuned to 165 kHz and the other to 6.78 MHz. We also provide an intuitive description and comparison of voltage-driven and current-driven CPLs. This topic is rarely treated in an intuitive manner and largely ignored, but we believe a solid conceptual understanding of voltage-driven and current-driven CPLs is beneficial for designers.
引用
收藏
页码:209762 / 209775
页数:14
相关论文
共 50 条
  • [21] Steady-State Multiple Parameters Estimation of the Inductive Power Transfer System
    Despotovic, Zivadin
    Reljic, Dejan
    Vasic, Veran
    Oros, Djura
    IEEE ACCESS, 2022, 10 : 46878 - 46894
  • [22] A Novel Design Method of LCC-S Compensated Inductive Power Transfer System Combining Constant Current and Constant Voltage Mode via Frequency Switching
    Wang, Wenbo
    Deng, Junjun
    Chen, Deliang
    Wang, Zhenpo
    Wang, Shuo
    IEEE ACCESS, 2021, 9 : 117244 - 117256
  • [23] Instability Mitigation of Constant Power Load in Microgrid
    Hassan, Mohamed A.
    Worku, Muhammed Y.
    Eladl, Abdelfattah A.
    Elkadeem, Mohamed R.
    Hossain, Md Ismail
    Abido, Mohammad A.
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024, 49 (05) : 7341 - 7358
  • [24] Obtaining Maximum Efficiency of Inductive Power-Transfer System by Impedance Matching Based on Boost Converter
    Zhang, Kehan
    Ye, Tianwei
    Yan, Zhengchao
    Song, Baowei
    Hu, Aiguo Patrick
    IEEE TRANSACTIONS ON TRANSPORTATION ELECTRIFICATION, 2020, 6 (02) : 488 - 496
  • [25] A Power Adaptive Impedance Reshaping Strategy for Cascaded DC System With Buck-Type Constant Power Load
    He, Bangbang
    Chen, Wu
    Li, Xin
    Shu, Liangcai
    Ruan, Xinbo
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2022, 37 (08) : 8909 - 8920
  • [26] Data Center Power System Stability - Part II: System Modeling and Analysis
    Sun, Jian
    Mihret, Melaku
    Cespedes, Mauricio
    Wong, David
    Kauffman, Mike
    CSEE JOURNAL OF POWER AND ENERGY SYSTEMS, 2022, 8 (02) : 420 - 438
  • [27] The Effect of a Constant Power Load on the Stability of a Smart Transformer
    De Cristofaro, M.
    Femia, N.
    Petrone, G.
    Buticchi, G.
    De Carne, G.
    Liserre, M.
    PROCEEDINGS 2015 IEEE INTERNATIONAL CONFERENCE ON INDUSTRIAL INFORMATICS (INDIN), 2015, : 1605 - 1610
  • [28] Minimizing Current in Inductive Power Transfer Systems With an Asymmetrical Factor for Misalignment Tolerance and Wide Load Range
    Yao, Zirui
    Zhang, Junjie
    Luo, Shiying
    Luo, Zhongbao
    Zheng, Shaoting
    Li, Guanxi
    Zhang, Zhuhaobo
    Krein, Philip T.
    Ma, Hao
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (09) : 9886 - 9896
  • [29] Large Signal Stability Analysis of DC Microgrid under Droop Control with Constant Power Load
    Zhao, Zhongtian
    Hu, Jian
    Xue, Haochen
    Huang, Ronghui
    Li, Xun
    Zhang, Xin
    2017 CHINESE AUTOMATION CONGRESS (CAC), 2017, : 1046 - 1051
  • [30] Constant-Power Load System Stabilization by Passive Damping
    Cespedes, Mauricio
    Xing, Lei
    Sun, Jian
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2011, 26 (07) : 1832 - 1836