Morphine determination by HPLC with improved chemiluminescence detection using a conventional silica based column

被引:14
作者
Amiott, E
Andrews, ARJ
机构
[1] Department of Chemistry, Ohio University, Athens
关键词
D O I
10.1080/10826079708010655
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A new high performance liquid chromatography-chemiluminescence analysis system for morphine is described. This system has an on-column limit of detection of 20 pg for morphine, allowing morphine determination down to 1 ng/mL, with a 20 mu L injection size, without any concentration during sample preparation. Simultaneous determination of monoacetylmorphine to 15 ng/mL (300 pg on-column) is also achieved. The internal standard for both compounds is nalorphine and total analysis time is under 5 minutes.
引用
收藏
页码:311 / 325
页数:15
相关论文
共 14 条
[1]   DETERMINATION OF MORPHINE IN BODY-FLUIDS BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH CHEMILUMINESCENCE DETECTION [J].
ABBOTT, RW ;
TOWNSHEND, A ;
GILL, R .
ANALYST, 1987, 112 (04) :397-406
[2]   DETERMINATION OF MORPHINE BY FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
ABBOTT, RW ;
TOWNSHEND, A ;
GILL, R .
ANALYST, 1986, 111 (06) :635-640
[3]  
ANDREWS ARJ, 1990, THESIS U HULL UK
[4]   DETERMINATION OF MORPHINE IN-PROCESS STREAMS USING FLOW-INJECTION ANALYSIS WITH CHEMILUMINESCENCE DETECTION [J].
BARNETT, NW ;
ROLFE, DG ;
BOWSER, TA ;
PATON, TW .
ANALYTICA CHIMICA ACTA, 1993, 282 (03) :551-557
[5]   SIMULTANEOUS SOLID-PHASE EXTRACTION AND CHROMATOGRAPHIC ANALYSIS OF MORPHINE AND HYDROMORPHONE IN PLASMA BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
BOUQUILLON, AI ;
FREEMAN, D ;
MOULIN, DE .
JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1992, 577 (02) :354-357
[6]   ELECTROGENERATED CHEMILUMINESCENT DETERMINATION OF CODEINE AND RELATED ALKALOIDS AND PHARMACEUTICALS WITH TRIS(2,2'-BIPYRIDINE)RUTHENIUM(II) [J].
GREENWAY, GM ;
KNIGHT, AW ;
KNIGHT, PJ .
ANALYST, 1995, 120 (10) :2549-2552
[7]   ANALYSIS OF COMMON OPIATES AND HEROIN METABOLITES IN URINE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
LOW, AS ;
TAYLOR, RB .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1995, 663 (02) :225-233
[8]  
POOLE CK, 1991, CHROMATOGRAPHY TODAY, P335
[9]   HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC STUDY OF CODEINE, NORCODEINE, AND MORPHINE AS INDICATORS OF CODEINE INGESTION [J].
POSEY, BL ;
KIMBLE, SN .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1984, 8 (02) :68-74
[10]   DETERMINATION OF 6-MONOACETYLMORPHINE AND MORPHINE IN PLASMA, WHOLE-BLOOD AND URINE USING HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION [J].
ROP, PP ;
GRIMALDI, F ;
BURLE, J ;
DESAINTLEGER, MN ;
VIALA, A .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 1994, 661 (02) :245-253