Experience with silicon detectors at the DELPHI experiment, LEP

被引:5
作者
Collins, P
机构
[1] CERN
关键词
D O I
10.1016/S0168-9002(96)00623-7
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
New measurements are reported on modules of both the current DELPHI vertex detector, which was installed in 1994, and the upgraded detector which will be installed in 1996. These measurements include an analysis of the phenomenon of ''micro-discharge'' noise on the ohmic side of double sided detectors, an observation of variable depletion regions on double sided detectors, and the first test results for the 24 cm long back-to-back modules for the upgraded detector. For the detector presently in operation it has been possible to confirm measurements with tracks from the DELPHI data.
引用
收藏
页码:1 / 6
页数:6
相关论文
共 50 条
[41]   The performance of the Delphi Jadron Calorimeter at LEP [J].
Ajinenko, I ;
Beloous, K ;
Chudoba, J ;
Czellar, S ;
Herr, H ;
Jouravlev, N ;
Khovansky, N ;
Kluit, P ;
Krumstein, Z ;
Kurvinen, K ;
Lapin, V ;
Leitner, R ;
Masik, J ;
Olchevski, A ;
Ridky, J ;
Sedykh, Y ;
Sicho, P ;
Smirnova, O ;
Solovianov, O ;
Tchikilev, O ;
Tkatchev, L ;
Tomsa, Z ;
Vrba, V ;
Williams, WS ;
Wetherell, AM ;
Zaslavsky, J .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1996, 43 (03) :1751-1756
[42]   b-tagging in DELPHI at LEP [J].
Abreu, P ;
Adam, W ;
Adye, T ;
Adzic, P ;
Albrecht, T ;
Alderweireld, T ;
Alemany-Fernandez, R ;
Allmendinger, T ;
Allport, PP ;
Almehed, S ;
Amaldi, U ;
Amapane, N ;
Amato, S ;
Anashkin, E ;
Andreazza, A ;
Andringa, S ;
Anjos, N ;
Antilogus, P ;
Apel, WD ;
Arnoud, Y ;
Ask, S ;
Asman, B ;
Augustin, JE ;
Augustinus, A ;
Baillon, P ;
Ballestrero, A ;
Bambade, P ;
Barbier, R ;
Bardin, D ;
Barker, G ;
Baroncelli, A ;
Bates, M ;
Battaglia, M ;
Baubillier, M ;
Becks, KH ;
Begalli, M ;
Behrmann, A ;
Benekos, N ;
Benvenuti, A ;
Berat, C ;
Berggren, M ;
Berntzon, L ;
Bertrand, D ;
Besancon, M ;
Besson, N ;
Bibby, J ;
Biffi, P ;
Bloch, D ;
Blom, M ;
Bonesini, M .
EUROPEAN PHYSICAL JOURNAL C, 2004, 32 (02) :185-208
[43]   Image compression for the silicon drift detectors in the ALICE experiment [J].
Werbrouck, A ;
Tosello, F ;
Rivetti, A ;
Mazza, G ;
De Remigis, P ;
Cavagnino, D ;
Alberici, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 471 (1-2) :281-284
[44]   Silicon drift detectors for the STAR/SVT experiment at RHIC [J].
Takahashi, J ;
Bellwied, R ;
Beuttenmuller, R ;
Caines, H ;
Chen, W ;
DiMassimo, D ;
Dyke, H ;
Elliot, D ;
Grau, M ;
Hoffmann, GW ;
Humanic, T ;
Jensen, P ;
Kotov, IV ;
Kraner, HW ;
Kuczewski, P ;
Leonhardt, W ;
Li, Z ;
Liaw, C ;
LoCurto, G ;
Lynn, D ;
Mazeh, N ;
Middelkamp, P ;
Minor, R ;
Nehmeh, S ;
Ott, G ;
Pandey, SU ;
Pinelli, D ;
Pruneau, C ;
Rykov, VL ;
Schambach, J ;
Sedlmeir, J ;
Sheen, J ;
Soja, R ;
Stefani, D ;
Sugarbaker, E ;
Wilson, WK .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 439 (2-3) :497-506
[45]   Charm identification using silicon detectors in a neutrino experiment [J].
Ellis, M ;
Soler, FJP .
JOURNAL OF PHYSICS G-NUCLEAR AND PARTICLE PHYSICS, 2003, 29 (08) :1975-1979
[46]   Charge collection in the Silicon Drift Detectors of the ALICE experiment [J].
Alessandro, B. ;
Bala, R. ;
Batigne, G. ;
Beole, S. ;
Biolcati, E. ;
Cerello, P. ;
Coli, S. ;
Corrales Morales, Y. ;
Crescio, E. ;
De Remigis, P. ;
Falchieri, D. ;
Giraudo, G. ;
Giubellino, P. ;
Lea, R. ;
Chiesa, A. Marzari ;
Masera, M. ;
Mazza, G. ;
Ortona, G. ;
Prino, F. ;
Ramello, L. ;
Rashevsky, A. ;
Riccati, L. ;
Rivetti, A. ;
Senyukov, S. ;
Siciliano, M. ;
Sitta, M. ;
Subieta, M. ;
Toscano, L. ;
Tosello, F. .
JOURNAL OF INSTRUMENTATION, 2010, 5
[47]   Determination of |Vub|/|Vcb| with DELPHI at LEP [J].
Abreu, P ;
Adam, W ;
Adye, T ;
Adzic, P ;
Albrecht, Z ;
Alderweireld, T ;
Alekseev, GD ;
Alemany, R ;
Allmendinger, T ;
Allport, PP ;
Almehed, S ;
Amaldi, U ;
Amapane, N ;
Amato, S ;
Anassontzis, EG ;
Andersson, P ;
Andreazza, A ;
Andringa, S ;
Antilogus, P ;
Apel, WD ;
Arnoud, Y ;
Åsman, B ;
Augustin, JE ;
Augustinus, A ;
Baillon, P ;
Bambade, P ;
Barao, F ;
Barbiellini, G ;
Barbier, R ;
Bardin, DY ;
Barker, G ;
Baroncelli, A ;
Battaglia, M ;
Baubillier, M ;
Becks, KH ;
Begalli, M ;
Behrmann, A ;
Beilliere, P ;
Belokopytov, Y ;
Belous, K ;
Benekos, M ;
Benvenuti, AC ;
Berat, C ;
Berggren, M ;
Bertrand, D ;
Besancon, M ;
Bigi, M ;
Bilenky, MS ;
Bizouard, MA ;
Bloch, D .
PHYSICS LETTERS B, 2000, 478 (1-3) :14-30
[48]   b-tagging in DELPHI at LEP [J].
The European Physical Journal C - Particles and Fields, 2004, 32 :299-301
[49]   The performance of the Delphi Hadron Calorimeter at LEP [J].
Ajinenko, I ;
Beloous, K ;
Chudoba, J ;
Czellar, S ;
Herr, H ;
Jouravlev, N ;
Khovansky, N ;
Kluit, P ;
Krumstein, Z ;
Kurvinen, K ;
Lapin, V ;
Leitner, R ;
Masik, J ;
Nikolaenko, V ;
Olchevski, A ;
Ridky, J ;
Sedykh, Y ;
Sicho, P ;
Smirnova, O ;
Solovianov, O ;
Tchikilev, O ;
Tkatchev, L ;
Tomsa, Z ;
Vrba, V ;
Williams, WS ;
Wetherell, AM ;
Zaslavsky, J .
1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, :723-727
[50]   b-tagging in DELPHI at LEP [J].
The European Physical Journal C - Particles and Fields, 2004, 32 :185-208