Kinetic analysis and modelling of the ageing process for Kraft paper aged in natural ester dielectric fluid

被引:3
作者
Ding, H. -Z. [1 ]
Wang, Z. D. [1 ]
机构
[1] Univ Manchester, Sch Elect Engn & Elect, Manchester M60 1QD, Lancs, England
来源
2006 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA | 2006年
关键词
D O I
10.1109/CEIDP.2006.311980
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper describes briefly various different degradation kinetic models of cellulose and paper insulation in the literature and presents a new cumulative degradation kinetic model for loss of tensile strength of cellulose and paper insulation. Applying this model, the predicted loss of tensile strength has been compared with accelerated ageing data of Kraft paper obtained from the publications of McShane et al. of Cooper Power System. McShane et al. conducted the ageing of Kraft paper in both mineral oil and natural ester in sealed tube at elevated temperatures. It is shown that the cumulative degradation kinetic model for loss of tensile strength of paper insulation can give an excellent description of the ageing process of Kraft paper insulation in both natural ester dielectric fluid and mineral transformer oil.
引用
收藏
页码:505 / 508
页数:4
相关论文
共 11 条
  • [1] DING HZ, 2005, IEE C PUBLICATION, V508, P315
  • [2] REVIEW OF CHEMICAL INDICATORS OF DEGRADATION OF CELLULOSIC ELECTRICAL PAPER INSULATION IN OIL-FILLED TRANSFORMERS
    EMSLEY, AM
    STEVENS, GC
    [J]. IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 1994, 141 (05) : 324 - 334
  • [3] On the kinetics of degradation of cellulose
    Emsley, AM
    Heywood, RJ
    Ali, M
    Eley, CM
    [J]. CELLULOSE, 1997, 4 (01) : 1 - 5
  • [4] Degradation of cellulosic insulation in power transformers. Part 4: Effects of ageing on the tensile strength of paper
    Emsley, AM
    Heywood, RJ
    Ali, M
    Xiao, X
    [J]. IEE PROCEEDINGS-SCIENCE MEASUREMENT AND TECHNOLOGY, 2000, 147 (06) : 285 - 290
  • [5] *IEEE, C57921995 IEEE
  • [6] INSULATION THERMAL LIFE CONSIDERATIONS FOR TRANSFORMER LOADING GUIDES
    MCNUTT, WJ
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 1992, 7 (01) : 392 - 401
  • [7] Aging of paper insulation retrofilled with natural ester dielectric fluid
    McShane, CP
    Corkran, JL
    Rapp, KJ
    Luksich, J
    [J]. 2003 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTRIC PHENOMENA, 2003, : 124 - 127
  • [8] Aging of Kraft paper in natural ester dielectric fluid
    McShane, CP
    Rapp, KJ
    Corkran, JL
    Gauger, GA
    Luksich, J
    [J]. PROCEEDINGS OF THE 2002 IEEE 14TH INTERNATIONAL CONFERENCE ON DIELECTRIC LIQUIDS, 2002, : 173 - 177
  • [9] Aging of paper insulation in natural ester dielectric fluid
    McShane, CP
    Rapp, KJ
    Corkran, JL
    Gauger, GA
    Luksich, J
    [J]. 2001 IEEE/PES TRANSMISSION AND DISTRIBUTION CONFERENCE AND EXPOSITION, VOLS 1 AND 2: DEVELOPING NEW PERSPECTIVES, 2001, : 675 - 679
  • [10] Moser H. P., 1987, TRANSFORMERBOARD