The development and assessment of high-throughput mass spectrometry-based methods for the quantification of a nanoparticle drug delivery agent in cellular lysate

被引:14
作者
Buse, Joshua [1 ]
Purves, Randy W. [1 ,2 ]
Verrall, Ronald E. [3 ]
Badea, Ildiko [1 ]
Zhang, Haixia [2 ]
Mulligan, Christopher C. [4 ]
Peru, Kerry M. [5 ]
Bailey, Jonathan [5 ]
Headley, John V. [5 ]
El-Aneed, Anas [1 ]
机构
[1] Univ Saskatchewan, Coll Pharm & Nutr, Saskatoon, SK S7N 5C9, Canada
[2] Natl Res Council Canada, Mass Spectrometry Lab, Saskatoon, SK S7N 0W9, Canada
[3] Univ Saskatchewan, Dept Chem, Saskatoon, SK S7N 5C9, Canada
[4] Illinois State Univ, Dept Chem, Normal, IL 61790 USA
[5] Environm Canada, Aquat Contaminant Res Div, Water Sci & Technol Directorate, Saskatoon, SK S7N 3H5, Canada
来源
JOURNAL OF MASS SPECTROMETRY | 2014年 / 49卷 / 11期
基金
加拿大自然科学与工程研究理事会; 加拿大创新基金会;
关键词
mass spectrometry; quantification; liquid chromatography; fast chromatography; desorption electrospray ionization; matrix assisted laser desorption ionization; drug delivery; gemini surfactants; LIQUID-CHROMATOGRAPHY; QUANTITATIVE-DETERMINATION; ION-TRAP; PHARMACEUTICAL DRUGS; HUMAN PLASMA; LC-MS/MS; TIME; PERFORMANCE; SAMPLES; BIOANALYSIS;
D O I
10.1002/jms.3444
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The safe use of lipid-based drug delivery agents requires fast and sensitive qualitative and quantitative assessment of their cellular interactions. Many mass spectrometry (MS) based analytical platforms can achieve such task with varying capabilities. Therefore, four novel high-throughput MS-based quantitative methods were evaluated for the analysis of a small organic gene delivery agent: N,N-bis(dimethylhexadecyl)-1,3-propane-diammonium dibromide (G16-3). Analysis utilized MS instruments that detect analytes using low-resolution tandem MS (MS/MS) analysis (i.e. QTRAP or linear ion trap in this work) or high-resolution MS analysis (i.e. time of flight (ToF) or Orbitrap). Our results indicate that the validated fast chromatography (FC)-QTRAP-MS/MS, FC- LTQ-Orbitrap-MS, desorption electrospray ionization-collision-induced dissociation (CID)-MS/MS and matrix assisted laser desorption ionization-ToF/ToF-MS MS methods were superior in the area of method development and sample analysis time to a previously developed liquid chromatography (LC)-CID-MS/MS. To our knowledge, this is the first evaluation of the abilities of five MS-based quantitative methods that target a single pharmaceutical analyte. Our findings indicate that, in comparison to conventional LC-CID-MS/MS, the new MS-based methods resulted in a (1) substantial reduction in the analysis time, (2) reduction in the time required for method development and (3) production of either superior or comparable quantitative data. The four new high-throughput MS methods, therefore, were faster, more efficient and less expensive than a conventional LC-CID-MS/MS for the quantification of the G16-3 analyte within tissue culture. When applied to cellular lysate, no significant change in the concentration of G16-3 gemini surfactant within PAM212 cells was observed between 5 and 53h, suggesting the absence of any metabolism/excretion from PAM212 cells. Copyright (c) 2014 John Wiley & Sons, Ltd.
引用
收藏
页码:1171 / 1180
页数:10
相关论文
共 50 条
[1]  
[Anonymous], 2013, Guidance for industry, bioanalytical method validation
[2]   Delivering the goods: viral and non-viral gene therapy systems and the inherent limits on cargo DNA and internal sequences [J].
Atkinson, Helen ;
Chalmers, Ronald .
GENETICA, 2010, 138 (05) :485-498
[3]   In vivo cutaneous interferon-γ gene delivery using novel dicationic (gemini) surfactant-plasmid complexes [J].
Badea, I ;
Verrall, R ;
Baca-Estrada, M ;
Tikoo, S ;
Rosenberg, A ;
Kumar, P ;
Foldvari, M .
JOURNAL OF GENE MEDICINE, 2005, 7 (09) :1200-1214
[4]   Quantification of hepcidin using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry [J].
Bansal, Sukhvinder S. ;
Halket, John M. ;
Fusova, Jane ;
Bomford, Adrian ;
Simpson, Robert J. ;
Vasavda, Nisha ;
Thein, Swee Lay ;
Hider, Robert C. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2009, 23 (11) :1531-1542
[5]   Development of High-Throughput Chemical Extraction Techniques and Quantitative HPLC-MS/MS (SRM) Assays for Clinically Relevant Plasma Proteins [J].
Barton, Chris ;
Kay, Richard G. ;
Gentzer, Wolfgang ;
Vitzthum, Frank ;
Pleasance, Steve .
JOURNAL OF PROTEOME RESEARCH, 2010, 9 (01) :333-340
[6]   Novel Gemini Pyridinium Surfactants: Synthesis and Study of Their Surface Activity, DNA Binding, and Cytotoxicity [J].
Bhadani, Avinash ;
Singh, Sukhprit .
LANGMUIR, 2009, 25 (19) :11703-11712
[7]   In vitro myotoxicity of selected cationic macromolecules used in non-viral gene delivery [J].
Brazeau, GA ;
Attia, S ;
Poxon, S ;
Hughes, JA .
PHARMACEUTICAL RESEARCH, 1998, 15 (05) :680-684
[8]   A general liquid chromatography tandem mass spectrometry method for the quantitative determination of diquaternary ammonium gemini surfactant drug delivery agents in mouse keratinocytes' cellular lysate [J].
Buse, Joshua ;
Badea, Ildiko ;
Verrall, Ronald E. ;
El-Aneed, Anas .
JOURNAL OF CHROMATOGRAPHY A, 2013, 1294 :98-105
[9]   A Self-validating Quantitative Mass Spectrometry Method for Assessing the Accuracy of High-content Phosphoproteomic Experiments [J].
Casado, Pedro ;
Cutillas, Pedro R. .
MOLECULAR & CELLULAR PROTEOMICS, 2011, 10 (01)
[10]   Desorption electrospray ionization mass spectrometry for high-throughput analysis of pharmaceutical samples in the ambient environment [J].
Chen, HW ;
Talaty, NN ;
Takáts, Z ;
Cooks, RG .
ANALYTICAL CHEMISTRY, 2005, 77 (21) :6915-6927