Quantitative passive soil vapor sampling for VOCs - part 4: flow-through cell

被引:7
作者
McAlary, Todd [1 ]
Groenevelt, Hester [1 ]
Seethapathy, Suresh [2 ]
Sacco, Paolo [3 ]
Crump, Derrick [4 ]
Tuday, Michael [5 ]
Schumacher, Brian [6 ]
Hayes, Heidi [7 ]
Johnson, Paul [8 ]
Parker, Louise
Gorecki, Tadeusz [2 ]
机构
[1] Geosyntec Consultants Inc, Guelph, ON N1G 5G3, Canada
[2] Univ Waterloo, Waterloo, ON N2L 3G1, Canada
[3] Fdn Salvatore Maugeri, Padua, Italy
[4] Cranfield Univ, Cranfield MK43 0AL, Beds, England
[5] Columbia Analyt Serv, Simi Valley, CA USA
[6] US EPA, Las Vegas, NV USA
[7] Eurofins Air Toxics Inc, Folsom, CA USA
[8] Arizona State Univ, Tempe, AZ USA
关键词
VOLATILE ORGANIC-COMPOUNDS; ENVIRONMENTAL-ANALYSIS; THERMAL-DESORPTION; AIR;
D O I
10.1039/c4em00098f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper presents a controlled experiment comparing several quantitative passive samplers for monitoring concentrations of volatile organic compound (VOC) vapors in soil gas using a flow-through cell. This application is simpler than conventional active sampling using adsorptive tubes because the flow rate does not need to be precisely measured and controlled, which is advantageous because the permeability of subsurface materials affects the flow rate and the permeability of geologic materials is highly variable. Using passive samplers in a flow-through cell, the flow rate may not need to be known exactly, as long as it is sufficient to purge the cell in a reasonable time and minimize any negative bias attributable to the starvation effect. An experiment was performed in a 500 mL flow-through cell using a two-factor, one-half fraction fractional factorial test design with flow rates of 80, 670 and 930 mL min(-1) and sample durations of 10, 15 and 20 minutes for each of five different passive samplers (passive Automatic Thermal Desorption Tube, Radiello (R), SKC Ultra, Waterloo Membrane Sampler (TM) and 3M (TM) OVM 3500). A Summa canister was collected coincident with each passive sampler and analyzed by EPA Method TO-15 to provide a baseline for comparison of the passive sampler concentrations. The passive sampler concentrations were within a factor of 2 of the Summa canister concentrations in 32 of 35 cases. Passive samples collected at the low flow rate and short duration showed low concentrations, which is likely attributable to insufficient purging of the cell after sampler placement.
引用
收藏
页码:1103 / 1111
页数:9
相关论文
共 36 条
[1]  
[Anonymous], 2003, PERF SKC ULTR SAMPL
[2]  
[Anonymous], 2011, D7758 ASTM
[3]  
[Anonymous], 2011, FIN GUID EV MIT SUBS
[4]  
[Anonymous], 1999, PA625R96010B US EPA
[5]  
[Anonymous], 1998, 600R98095 US EPA OFF
[6]  
[Anonymous], 1998, 600R98096 US EPA OFF
[7]  
[Anonymous], 2012, ADV ACT SOIL GAS INV
[8]  
[Anonymous], 2003, 160172 ISO
[9]  
[Anonymous], 2008, D624608 ASTM
[10]  
ASTM, 2009, D4597 ASTM