Effect of PD solutions on patient outcome

被引:4
作者
Lo, Wai-Kei [1 ]
机构
[1] Tung Wah Hosp, Dept Med, Hong Kong, Hong Kong, Peoples R China
来源
PERITONEAL DIALYSIS: A CLINICAL UPDATE | 2006年 / 150卷
关键词
D O I
10.1159/000093507
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
With the recognition of the bio-incompatibility of conventional glucose based peritoneal dialysate (PDF), many new PDF has been developed and commercially available. All of them contain much less low glucose degradation product (GDP) solutions. Additional features are neutral or physiological pH, or glucose replaced by amino acid or glucose polymer icodextrin. These fluid has been shown to be more biocompatible in in-vitro and animal studies. There are short term randomized studies showing some benefit in certain clinical criteria, like increase in CA 125 in effluent PDF, better preservation of residual renal function, nutritional status, fluid and cardiovascular status, but beneficial effect on patient survival and long term peritoneal function has not been demonstrated apart from a non-randomized cohort study. To show such benefit on patient outcome, long term prospective randomized study is needed. Copyright (c) 2006 S. Karger AG, Basel.
引用
收藏
页码:90 / 96
页数:7
相关论文
共 14 条
[11]   Dialysate as food: Combined amino acid and glucose dialysate improves protein anabolism in renal failure patients on automated peritoneal dialysis [J].
Tjiong, HL ;
van den Berg, JW ;
Wattimena, JL ;
Rietveld, T ;
van Dijk, LJ ;
van der Wiel, AM ;
van Egmond, AM ;
Fieren, MW ;
Swart, R .
JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2005, 16 (05) :1486-1493
[12]  
Tranaeus A., 2000, PERITON DIALYSIS INT, V20, P216
[13]  
Van Biesen W, 2004, PERITON DIALYSIS INT, V24, P222
[14]   The Euro-Balance Trial: The effect of a new biocompatible peritoneal dialysis fluid (balance) on the peritoneal membrane [J].
Williams, JD ;
Topley, N ;
Craig, KJ ;
Mackenzie, RK ;
Pischetsrieder, M ;
Lage, C ;
Passlick-Deetjen, J .