Interobserver agreement of lung ultrasound findings of COVID-19

被引:28
|
作者
Kumar, Andre [1 ]
Weng, Yingjie [2 ]
Graglia, Sally [3 ]
Chung, Sukyung [2 ]
Duanmu, Youyou [4 ]
Lalani, Farhan [5 ]
Gandhi, Kavita [3 ]
Lobo, Viveta [4 ]
Jensen, Trevor [5 ]
Nahn, Jeffrey [3 ]
Kugler, John [1 ]
机构
[1] Stanford Univ, Sch Med, Dept Med, Stanford, CA 94305 USA
[2] Stanford Univ, Quantitat Sci Unit, Stanford, CA 94305 USA
[3] Univ Calif San Francisco, Dept Emergency Med, San Francisco, CA 94143 USA
[4] Stanford Univ, Sch Med, Dept Emergency Med, Stanford, CA 94305 USA
[5] Univ Calif San Francisco, Dept Med, San Francisco, CA 94143 USA
关键词
COVID-19; interobserver agreement; interrater; lung; POCUS; reliability; SARS-CoV-2; ultrasound;
D O I
10.1002/jum.15620
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Background-Lung ultrasound (LUS) has received considerable interest in the clinical evaluation of patients with COVID-19. Previously described LUS manifestations for COVID-19 include B-lines, consolidations, and pleural thickening. The interrater reliability (IRR) of these findings for COVID-19 is unknown. Methods-This study was conducted between March and June 2020. Nine physicians (hospitalists: n = 4; emergency medicine: n = 5) from 3 medical centers independently evaluated n = 20 LUS scans (n = 180 independent observations) collected from patients with COVID-19, diagnosed via RT-PCR. These studies were randomly selected from an image database consisting of COVID-19 patients evaluated in the emergency department with portable ultrasound devices. Physicians were blinded to any patient information or previous LUS interpretation. Kappa values (kappa) were used to calculate IRR. Results-There was substantial IRR on the following items: normal LUS scan (kappa = 0.79 [95% CI: 0.72-0.87]), presence of B-lines (kappa = 0.79 [95% CI: 0.72-0.87]), >= 3 B-lines observed (kappa = 0.72 [95% CI: 0.64-0.79]). Moderate IRR was observed for the presence of any consolidation (kappa = 0.57 [95% CI: 0.50-0.64]), subpleural consolidation (kappa = 0.49 [95% CI: 0.42-0.56]), and presence of effusion (kappa = 0.49 [95% CI: 0.41-0.56]). Fair IRR was observed for pleural thickening (kappa = 0.23 [95% CI: 0.15-0.30]). Discussion-Many LUS manifestations for COVID-19 appear to have moderate to substantial IRR across providers from multiple specialties utilizing differing portable devices. The most reliable LUS findings with COVID-19 may include the presence/count of B-lines or determining if a scan is normal. Clinical protocols for LUS with COVID-19 may require additional observers for the confirmation of less reliable findings such as consolidations.
引用
收藏
页码:2369 / 2376
页数:8
相关论文
共 50 条
  • [31] The role of lung ultrasound in COVID-19 disease
    Clevert, Dirk-Andre
    Sidhu, Paul S.
    Lim, Adrian
    Ewertsen, Caroline
    Mitkov, Vladimir
    Piskunowicz, Maciej
    Ricci, Paolo
    Bargallo, Nuria
    Brady, Adrian P.
    INSIGHTS INTO IMAGING, 2021, 12 (01)
  • [32] The role of lung ultrasound in COVID-19 disease
    Insights into Imaging, 12
  • [33] Lung histopathological findings in COVID-19 disease - a systematic review
    Pannone, Giuseppe
    Caponio, Vito Carlo Alberto
    De Stefano, Ilenia Sara
    Ramunno, Maria Antonietta
    Meccariello, Mario
    Agostinone, Alessio
    Pedicillo, Maria Carmela
    Troiano, Giuseppe
    Zhurakivska, Khrystyna
    Cassano, Tommaso
    Bizzoca, Maria Eleonora
    Papagerakis, Silvana
    Buonaguro, Franco Maria
    Advani, Shailesh
    Lo Muzio, Lorenzo
    INFECTIOUS AGENTS AND CANCER, 2021, 16 (01)
  • [34] Lung ultrasound for the identification of COVID-19 pneumonia
    Gopar-Nieto, Rodrigo
    Rivas-Lasarte, Mercedes
    Moya-Alvarez, Alejandro
    Garcia-Cruz, Edgar
    Manzur-Sandoval, Daniel
    Arias-Mendoza, Alexandra
    Martinez, Daniel Sierra-Lara
    Araiza-Garaygordobil, Diego
    ARCHIVOS DE CARDIOLOGIA DE MEXICO, 2020, 90 : 15 - 18
  • [35] Lung ultrasound in the monitoring of COVID-19 infection
    Tung-Chen, Yale
    CLINICAL MEDICINE, 2020, 20 (04) : E62 - E65
  • [36] Lung ultrasound monitoring in patients with COVID-19 on home isolation
    Shokoohi, Hamid
    Duggan, Nicole M.
    Garcia-de-Casasola Sanchez, Gonzalo
    Torres-Arrese, Marta
    Tung-Chen, Yale
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2020, 38 (12) : 2759.e5 - 2759.e8
  • [37] Lung Ultrasound Integration in Assessment of Patients with Noncritical COVID-19
    Gil-Rodrigo, Adriana
    Llorens, Pere
    Luque-Hernandez, Maria-Jose
    Martinez-Buendia, Carmen
    Ramos-Rincon, Jose-Manuel
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (10) : 2203 - 2212
  • [38] Lung Ultrasound Findings Compared to Chest CT Scan in Patients with COVID-19 Associated Pneumonia: A Pilot Study
    Hatamabadi, Hamidreza
    Shojaee, Majid
    Bagheri, Mohammad
    Raoufi, Masoomeh
    FRONTIERS IN EMERGENCY MEDICINE, 2021, 5 (02):
  • [39] Diagnostic yield of point-of-care ultrasound imaging of the lung in patients with COVID-19
    Gil-Rodrigo, Adriana
    Llorens, Pere
    Martinez-Buendia, Carmen
    Luque-Hernandez, Maria-Jose
    Espinosa, Begona
    Manuel Ramos-Rincon, Jose
    EMERGENCIAS, 2020, 32 (05): : 340 - 344
  • [40] The importance of lung ultrasound in the diagnosis of COVID-19
    Wieclaw, Aleksandra
    Pawliczak, Rafal
    ALERGOLOGIA POLSKA-POLISH JOURNAL OF ALLERGOLOGY, 2023, 10 (04) : 286 - 294