Performance of a long-wave infrared Fourier Transform imaging spectrometer using a corner-cube Michelson interferometer and an uncooled microbolometer array

被引:2
作者
Wang Nan [1 ]
Wu Jianghui [1 ]
Meng Hemin [1 ]
Gao Jiaobo [1 ]
Fan Zhe [1 ]
Zhang Mingxuan [1 ]
Li Yu [1 ]
Li Jianjun [1 ]
机构
[1] Xian Inst Appl Opt, Xian 710065, Peoples R China
来源
AOPC 2015: OPTICAL AND OPTOELECTRONIC SENSING AND IMAGING TECHNOLOGY | 2015年 / 9674卷
关键词
imaging spectroscopy; corner-cube Michelson interferometer; long-wave infrared;
D O I
10.1117/12.2197096
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Interference imaging spectroscopy is the advanced subject among the infrared remote sensing, and it has become an important technique to detect spatial information and spectral information of targets. It has the advantages of high flux, high spectral resolution and high spatial resolution that can be used for detecting more details of the spectral and spatial information. Based on a Michelson interferometer with its mirrors replaced by corner-cubes, principles of a hand-held, static, long-wave infrared Fourier Transform(FT) imaging spectrometer using an uncooled microbolometer array are introduced. Because in such FT-based spectral imager, the interferogram is acquired over the whole field of the camera while the scene of interest scans the path difference range, vignetting should be strongly limited while keep the size of the interferometer as small as possible. Interferometer size is given and interferential light path is verified through TracePro software. First results of field and laboratory measurements using the spectral imager are presented. Remotely obtained spectrums collected with this instrument and with those of high precise Michelson spectrometer are compared, and the measured values turned out to be closely corresponded. The results, in turn, verified the feasibility of the systematic working mode. The resulting system tested here provides datacubes of up to 640x480 pixels over the 7.7 similar to 13 mu m spectral range, this wavelength range reveals important information about scenes such as gas or landmine detection, and the instrument has a spectral resolution of about 8cm(-1) that fulfils the requirement for most targeted applications. Examples of sky and buildings detection are shown.
引用
收藏
页数:8
相关论文
共 10 条
[1]  
Li Su-ning, 2009, Journal of Applied Optics, V30, P268
[2]  
Li Yu, 2014, Journal of Applied Optics, V35, P414, DOI 10.5768/JA0201435.0302003
[3]   Mini-SMIFTS: an uncooled LWIR hyperspectral sensor [J].
Lucey, PG ;
Wilcox, BB .
IMAGING SPECTROMETRY IX, 2003, 5159 :275-282
[4]  
Matallah Noura, 2011, P SOC PHOTO-OPT INS, V8167
[5]  
Meng Hemin, 2012, Infrared and Laser Engineering, V41, P2903
[6]   RADIOMETRIC CALIBRATION OF IR FOURIER-TRANSFORM SPECTROMETERS - SOLUTION TO A PROBLEM WITH THE HIGH-RESOLUTION INTERFEROMETER SOUNDER [J].
REVERCOMB, HE ;
BUIJS, H ;
HOWELL, HB ;
LAPORTE, DD ;
SMITH, WL ;
SROMOVSKY, LA .
APPLIED OPTICS, 1988, 27 (15) :3210-3218
[7]  
Xie Jinghui, 2007, FUNDAMENTALS FOURIER, P320
[8]   Studying the Attribution of LiF in OLED by the C-V Characteristics [J].
Zhang, Chun-lin ;
Wang, Fang-cong ;
Zhang, Yong ;
Li, Hai-xia ;
Liu, Su .
INTERNATIONAL JOURNAL OF PHOTOENERGY, 2010, 2010
[9]  
Zhang Ming-xuan, 2013, Journal of Applied Optics, V34, P452, DOI 10.5768/JA0201334.0302004
[10]  
Zhuo-xin JI, 2012, J APPL OPT, V33, P25