Intraobserver reproducibility and interobserver reliability of cervical spine measurements

被引:26
作者
Wellborn, CC [1 ]
Sturm, PF [1 ]
Hatch, RS [1 ]
Bomze, SR [1 ]
Jablonski, K [1 ]
机构
[1] Childrens Natl Med Ctr, Washington, DC 20010 USA
关键词
ADI; Down syndrome; Power's ratio; reliability; reproducibility; Wiesel-Rothman;
D O I
10.1097/00004694-200001000-00015
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Lateral flexion-extension radiographs of 72 patients with Down syndrome were used to assess the interobserver reliability and intraobserver reproducibility of the atlanto-dens interval, Wiesel-Rothman measurement, occiput atlas angle, and Power's ratio in flexion and extension. The radiographs were reviewed by three blinded observers on three different occasions with at Least a 1-month interval between assessments. The intraclass correlation coefficient was used to measure the reproducibility of the measurements from a given observer and the reliability between different observers. With the exception of observer one, the atlanto-dens interval had a statistically significant intraobserver agreement compared with any of the other measurements (p < 0.05). The atlanto-dens interval and the Wiesel-Rothman measurements tended to have better correlation between observers, although there was only fair agreement. The agreement, however, was statistically significant (p < 0.05) compared with Power's ratio. The degree of intraobserver reproducibility and interobserver reliability may make it difficult to base treatment protocols on these measurements.
引用
收藏
页码:66 / 70
页数:5
相关论文
共 25 条
  • [1] Classification of distal radius fractures: An analysis of interobserver reliability and intraobserver reproducibility
    Andersen, DJ
    Blair, WF
    Steyers, CM
    Adams, BD
    ElKhouri, GY
    Brandser, EA
    [J]. JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1996, 21A (04): : 574 - 582
  • [2] EVANS CLASSIFICATION OF TROCHANTERIC FRACTURES - AN ASSESSMENT OF THE INTEROBSERVER AND INTRAOBSERVER RELIABILITY
    ANDERSEN, E
    JORGENSEN, LG
    HEDEDAM, LT
    [J]. INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1990, 21 (06): : 377 - 378
  • [3] MEASUREMENT OF SCOLIOSIS AND KYPHOSIS RADIOGRAPHS - INTRAOBSERVER AND INTEROBSERVER VARIATION
    CARMAN, DL
    BROWNE, RH
    BIRCH, JG
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1990, 72A (03) : 328 - 333
  • [4] RADIOGRAPHIC SIGNS OF UNION OF SCAPHOID FRACTURES - AN ANALYSIS OF INTER-OBSERVER AGREEMENT AND REPRODUCIBILITY
    DIAS, JJ
    TAYLOR, M
    THOMPSON, J
    BRENKEL, IJ
    GREGG, PJ
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (02): : 299 - 301
  • [5] GARDEN CLASSIFICATION OF FEMORAL-NECK FRACTURES - AN ASSESSMENT OF INTER-OBSERVER VARIATION
    FRANDSEN, PA
    ANDERSEN, E
    MADSEN, F
    SKJODT, T
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1988, 70 (04): : 588 - 590
  • [6] OCCIPITOATLANTAL TRANSLATION IN DOWNS-SYNDROME
    GABRIEL, KR
    MASON, DE
    CARANGO, P
    [J]. SPINE, 1990, 15 (10) : 997 - 1002
  • [7] Jacobson S R, 1995, J Shoulder Elbow Surg, V4, P449, DOI 10.1016/S1058-2746(05)80037-0
  • [8] Reproducibility in the measurement of atlanto-occipital instability in children with Down syndrome
    Karol, LA
    Sheffield, EG
    Crawford, K
    Moody, MK
    Browne, RH
    [J]. SPINE, 1996, 21 (21) : 2463 - 2467
  • [9] KASSER JR, 1996, PEDIAT SPINE ORTHOPA, P565
  • [10] KAY RM, 1994, CLIN ORTHOP RELAT R, P124