Characterization of the impact to PET quantification and image quality of an anterior array surface coil for PET/MR imaging

被引:22
作者
Wollenweber, Scott D. [1 ]
Delso, Gaspar [1 ,2 ]
Deller, Timothy [1 ]
Goldhaber, David [1 ]
Huellner, Martin [2 ]
Veit-Haibach, Patrick [2 ]
机构
[1] GE Healthcare, Waukesha, WI 53186 USA
[2] Univ Zurich Hosp, CH-8091 Zurich, Switzerland
关键词
Positron-emission tomography; Magnetic resonance imaging; Attenuation correction; ATTENUATION CORRECTION; TIME;
D O I
10.1007/s10334-013-0388-1
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Object The aim of this study was to determine the impact to PET quantification, image quality and possible diagnostic impact of an anterior surface array used in a combined PET/MR imaging system. Materials and methods An extended oval phantom and 15 whole-body FDG PET/CT subjects were re-imaged for one bed position following placement of an anterior array coil at a clinically realistic position. The CT scan, used for PET attenuation correction, did not include the coil. Comparison, including liver SUVmean, was performed between the coil present and absent images using two methods of PET reconstruction. Due to the time delay between PET scans, a model was used to account for average physiologic time change of SUV. Results On phantom data, neglecting the coil caused a mean bias of -8.2 % for non-TOF/PSF reconstruction, and -7.3 % with TOF/PSF. On clinical data, the liver SUV neglecting the coil presence fell by -6.1 % (+/- 6.5 %) for non-TOF/PSF reconstruction; respectively-5.2 %(+/- 5.3 %) with TOF/PSF. All FDG-avid features seen with TOF/PSF were also seen with non-TOF/PSF reconstruction. Conclusion Neglecting coil attenuation for this anterior array coil results in a small but significant reduction in liver SUVmean but was not found to change the clinical interpretation of the PET images.
引用
收藏
页码:149 / 159
页数:11
相关论文
共 50 条
  • [21] PET/MR imaging of bone lesions - implications for PET quantification from imperfect attenuation correction
    Samarin, Andrei
    Burger, Cyrill
    Wollenweber, Scott D.
    Crook, David W.
    Burger, Irene A.
    Schmid, Daniel T.
    von Schulthess, Gustav K.
    Kuhn, Felix P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 (07) : 1154 - 1160
  • [22] A 16-channel MR coil for simultaneous PET/MR imaging in breast cancer
    Isabel Dregely
    Titus Lanz
    Stephan Metz
    Matthias F. Mueller
    Marika Kuschan
    Manoj Nimbalkar
    Ralph A. Bundschuh
    Sibylle I. Ziegler
    Axel Haase
    Stephan G. Nekolla
    Markus Schwaiger
    European Radiology, 2015, 25 : 1154 - 1161
  • [23] Quantitative hemodynamic PET imaging using image-derived arterial input function and a PET/MR hybrid scanner
    Su, Yi
    Vlassenko, Andrei G.
    Couture, Lars E.
    Benzinger, Tammie L. S.
    Snyder, Abraham Z.
    Derdeyn, Colin P.
    Raichle, Marcus E.
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2017, 37 (04) : 1435 - 1446
  • [24] Impact of Time-of-Flight PET on Quantification Errors in MR Imaging-Based Attenuation Correction
    Mehranian, Abolfazl
    Zaidi, Habib
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (04) : 635 - 641
  • [25] Accuracy of PET quantification in [68Ga]Ga-pentixafor PET/MR imaging of carotid plaques
    Rausch, Ivo
    Beitzke, Dietrich
    Li, Xiang
    Pfaff, Sahra
    Rasul, Sazan
    Haug, Alexander R.
    Mayerhoefer, Marius E.
    Hacker, Marcus
    Beyer, Thomas
    Cal-Gonzalez, Jacobo
    JOURNAL OF NUCLEAR CARDIOLOGY, 2022, 29 (02) : 492 - 502
  • [26] Accurate PET/MR Quantification Using Time of Flight MLAA Image Reconstruction
    Boellaard, R.
    Hofman, M. B. M.
    Hoekstra, O. S.
    Lammertsma, A. A.
    MOLECULAR IMAGING AND BIOLOGY, 2014, 16 (04) : 469 - 477
  • [27] Towards fast whole-body PET/MR: Investigation of PET image quality versus reduced PET acquisition times
    Lindemann, Maike E.
    Stebner, Vanessa
    Tschischka, Alexander
    Kirchner, Julian
    Umutlu, Lale
    Quick, Harald H.
    PLOS ONE, 2018, 13 (10):
  • [28] Radial k-space Acquisition Improves Robustness of MR-based Attenuation Maps for MR/PET Quantification in an Animal Imaging Study of the Abdomen
    Bini, Jason
    Robson, Philip
    Calcagno, Claudia
    Millon, Antoine
    Lobatto, Mark
    Fayad, Zahi A.
    2012 IEEE SIGNAL PROCESSING IN MEDICINE AND BIOLOGY SYMPOSIUM (SPMB), 2012,
  • [29] An experimental phantom study of the effect of gadolinium-based MR contrast agents on PET attenuation coefficients and PET quantification in PET-MR imaging: application to cardiac studies
    Jim O’ Doherty
    Paul Schleyer
    EJNMMI Physics, 4
  • [30] An experimental phantom study of the effect of gadolinium-based MR contrast agents on PET attenuation coefficients and PET quantification in PET-MR imaging: application to cardiac studies
    O'Doherty, Jim
    Schleyer, Paul
    EJNMMI PHYSICS, 2017, 4