Multi-channel pulse oximetry for wearable physiological monitoring

被引:0
作者
Mendelson, Y. [1 ]
Dao, D. K. [1 ]
Chon, K. H. [1 ]
机构
[1] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA 01609 USA
来源
2013 IEEE INTERNATIONAL CONFERENCE ON BODY SENSOR NETWORKS (BSN) | 2013年
关键词
Wearable sensors; pulse oximeter; motion artifacts; TRIAXIAL ACCELEROMETER; FOREHEAD; MOTION; PERFUSION; ACCURACY; EXERCISE; SIGNALS;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Pulse oximetry is a widely accepted clinical method for noninvasive monitoring of arterial oxygen saturation and pulse rate. Significant improvements aimed at curbing motion artifacts and improving reliability in detecting sufficiently strong photoplethysmographic signals are required to reduce errant measurements before the pulse oximeter can be considered for wider mobile applications. The present work describes the development of a wearable multi-channel reflectance pulse oximeter to investigate if a motion artifact-free signal can be obtained in at least one of the multi-channels at any given time. Pilot findings provided a proof of concept to support the hypothesis that photoplethysmograms acquired concurrently from independent channels in a multi-channel pulse oximeter sensor respond differently to motion artifacts, thus laying the foundation for future development of robust active noise cancellation and data fusion based algorithms to mitigate the effects of motion artifacts.
引用
收藏
页数:6
相关论文
共 19 条
  • [1] [Anonymous], C P IEEE EMBS 2006
  • [2] Mobile monitoring with wearable photoplethysmographic biosensors
    Asada, HH
    Shaltis, P
    Reisner, A
    Rhee, S
    Hutchinson, RC
    [J]. IEEE ENGINEERING IN MEDICINE AND BIOLOGY MAGAZINE, 2003, 22 (03): : 28 - 40
  • [3] Accuracy of pulse oximetry during intense exercise under severe hypoxic conditions
    Benoit, H
    Costes, F
    Feasson, L
    Lacour, JR
    Roche, F
    Denis, C
    Geyssant, A
    Barthelemy, JC
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1997, 76 (03) : 260 - 263
  • [4] Branson Richard D, 2004, Respir Care Clin N Am, V10, P359, DOI 10.1016/j.rcc.2004.04.003
  • [5] Comparison of desaturation and resaturation response times between transmission and reflectance pulse oximeters
    Choi, S. J.
    Ahn, H. J.
    Yang, M. K.
    Kim, C. S.
    Sim, W. S.
    Kim, J. A.
    Kang, J. G.
    Kim, J. K.
    Kang, J. Y.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2010, 54 (02) : 212 - 217
  • [6] REFLECTANCE PULSE OXIMETRY AT THE FOREHEAD IMPROVES BY PRESSURE ON THE PROBE
    DASSEL, ACM
    GRAAFF, R
    SIKKEMA, M
    MEIJER, A
    ZIJLSTRA, WG
    AARNOUDSE, JG
    [J]. JOURNAL OF CLINICAL MONITORING, 1995, 11 (04): : 237 - 244
  • [7] A computational system to optimise noise rejection in photoplethysmography signals during motion or poor perfusion states
    Foo, Jong Yong A.
    Wilson, Stephen J.
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2006, 44 (1-2) : 140 - 145
  • [8] Masimo signal extraction pulse oximetry
    Goldman, JM
    Petterson, MT
    Kopotic, RJ
    Barker, SJ
    [J]. JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2000, 16 (07) : 475 - 483
  • [9] Implementation of a real-time human movement classifier using a triaxial accelerometer for ambulatory monitoring
    Karantonis, DM
    Narayanan, MR
    Mathie, M
    Lovell, NH
    Celler, BG
    [J]. IEEE TRANSACTIONS ON INFORMATION TECHNOLOGY IN BIOMEDICINE, 2006, 10 (01): : 156 - 167
  • [10] Detection of daily physical activities using a triaxial accelerometer
    Mathie, MJ
    Coster, ACF
    Lovell, NH
    Celler, BG
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2003, 41 (03) : 296 - 301