A novel amperometric biosensor for xanthine was developed based on covalent immobilization of crude xanthine oxidase (XOD) extracted from bovine milk onto a hybrid nanocomposite film via glutaraldehyde. Toward the preparation of the film, a stable colloids solution of core-shell Fe3O4/polyaniline nanoparticles (PANI/Fe3O4 NPs) was dispersed in solution containing chitosan (CHT) and H2PtCl6 and electrodeposited over the surface of a carbon paste electrode (CPE) in one step. Scanning electron microscopy (SEM), Fourier transform infrared (FTIR) spectrophotometry, cyclic voltammetry (CV), and electrochemical impedance spectroscopy (EIS) were used for characterization of the electrode surface. The developed biosensor (XOD/CHT/Pt NPs/PANI/Fe3O4/CPE) was employed for determination of xanthine based on amperometric detection of hydrogen peroxide (H2O2) reduction at -0.35 V (vs. Ag/AgCl). The biosensor exhibited a fast response time to xanthine within 8 s and a linear working concentration range from 0.2 to 36.0 mu M (R-2 = 0.997) with a detection limit of 0.1 mu M (signal/noise [S/N] = 3). The sensitivity of the biosensor was 13.58 mu A mu M-1 cm(-2). The apparent Michaelis-Menten (K-m) value for xanthine was found to be 4.7 mu M. The fabricated biosensor was successfully applied for measurement of fish and chicken meat freshness, which was in agreement with the standard method at the 95% confidence level. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:51 / 59
页数:9
相关论文
共 38 条
  • [1] Identification of proteolytic products as indicators of quality in ground and whole meat
    Alomirah, HF
    Alli, I
    Gibbs, BF
    Konishi, Y
    [J]. JOURNAL OF FOOD QUALITY, 1998, 21 (04) : 299 - 316
  • [2] Three-way partial least-squares regression for the simultaneous kinetic-enzymatic determination of xanthine and hypoxanthine in human urine
    Amigo, JM
    Coello, J
    Maspoch, S
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2005, 382 (06) : 1380 - 1388
  • [3] Anik Ü, 2008, TURK J CHEM, V32, P711
  • [4] Application of Bismuth(III)-Entrapped XO Biosensing System for Xanthine Determination in Beverages
    Anik, Ulku
    Cubukcu, Meliha
    [J]. FOOD ANALYTICAL METHODS, 2012, 5 (04) : 716 - 722
  • [5] Label-free detection of aflatoxin M1 with electrochemical Fe3O4/polyaniline-based aptasensor
    Binh Hai Nguyen
    Lam Dai Tran
    Quan Phuc Do
    Huy Le Nguyen
    Ngoc Huan Tran
    Phuc Xuan Nguyen
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2013, 33 (04): : 2229 - 2234
  • [6] Design of a new hypoxanthine biosensor: xanthine oxidase modified carbon film and multi-walled carbon nanotube/carbon film electrodes
    Carolina Torres, A.
    Emilia Ghica, M.
    Brett, Christopher M. A.
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2013, 405 (11) : 3813 - 3822
  • [7] Immobilizing Pt nanoparticles and chitosan hybrid film on polyaniline naofibers membrane for an amperometric hydrogen peroxide biosensor
    Chen, Shihong
    Fu, Ping
    Yin, Bing
    Yuan, Ruo
    Chai, Yaqin
    Xiang, Yun
    [J]. BIOPROCESS AND BIOSYSTEMS ENGINEERING, 2011, 34 (06) : 711 - 719
  • [8] Quantification of uric acid, xanthine and hypoxanthine in human serum by HPLC for pharmacodynamic studies
    Cooper, Nancy
    Khosravan, Reza
    Erdmann, Carol
    Fiene, John
    Lee, Jean W.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 837 (1-2): : 1 - 10
  • [9] A method for determination of xanthine in meat by amperometric biosensor based on silver nanoparticles/cysteine modified Au electrode
    Devi, Rooma
    Batra, Bhawna
    Lata, Suman
    Yadav, Sandeep
    Pundir, C. S.
    [J]. PROCESS BIOCHEMISTRY, 2013, 48 (02) : 242 - 249
  • [10] Electrochemical biosensor based on gold coated iron nanoparticles/chitosan composite bound xanthine oxidase for detection of xanthine in fish meat
    Devi, Rooma
    Yadav, Sandeep
    Nehra, Renuka
    Yadav, Sujata
    Pundir, C. S.
    [J]. JOURNAL OF FOOD ENGINEERING, 2013, 115 (02) : 207 - 214