Digital holographic microscopy with sequential off-axis illumination directions based on spatial light modulator

被引:2
|
作者
Han, Junhe [1 ]
Hai, Fusheng [1 ]
Gu, Yuzong [1 ]
Huang, Mingju [1 ]
机构
[1] Henan Univ, Sch Phys & Elect, Kaifeng, Peoples R China
基金
中国国家自然科学基金;
关键词
hologram reconstruction; digital holographic microscopy; image distortion compensation; POINT-DIFFRACTION INTERFEROMETRY; NUMERICAL RECONSTRUCTION; ABERRATION COMPENSATION; CONTRAST; SUPERRESOLUTION; ANAMORPHISM; LENS; PAIR;
D O I
10.1080/09500340.2014.902516
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Digital holographic microscopy (DHM) with time-sequential off-axis illumination directions can synthesize a large aperture, and thus have a higher spatial resolution than the one with on-axis illumination. In this paper, time-sequential off-axis illumination directions are generated by a spatial light modulator (SLM) in DHM, and the residual phases along different illumination directions are suppressed by using the phase compensation technique, as such the image with resolution enhancement is reconstructed. The usage of SLM enables shifting the illumination for different orientations and phase shifts without mechanical motion. The experiments have been conducted to verify the feasibility of this method on the residual phase suppression.
引用
收藏
页码:615 / 620
页数:6
相关论文
共 50 条
  • [1] Analysis of off-axis incoherent digital holographic microscopy
    Quan, Xiangyu
    Matoba, Osamu
    Awatsuji, Yasuhiro
    THREE-DIMENSIONAL IMAGING, VISUALIZATION, AND DISPLAY 2017, 2017, 10219
  • [2] Study of spatial lateral resolution in off-axis digital holographic microscopy
    Doblas, Ana
    Sanchez-Ortiga, Emilio
    Martinez-Corral, Manuel
    Garcia-Sucerquia, Jorge
    OPTICS COMMUNICATIONS, 2015, 352 : 63 - 69
  • [3] Autofocusing of digital holographic microscopy based on off-axis illuminations
    Gao, Peng
    Yao, Baoli
    Min, Junwei
    Guo, Rongli
    Ma, Baiheng
    Zheng, Juanjuan
    Lei, Ming
    Yan, Shaohui
    Dan, Dan
    Ye, Tong
    OPTICS LETTERS, 2012, 37 (17) : 3630 - 3632
  • [4] Off-axis digital lensless holographic microscopy based on spatially multiplexed interferometry
    Picazo-Bueno, Jose angel
    Ketelhut, Steffi
    Schnekenburger, Juergen
    Mico, Vicente
    Kemper, Bjoern
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29
  • [5] Compensation enhancement by the patch-based inpainting in off-axis digital holographic microscopy
    Ma, Shujun
    Luo, Yu
    Yu, Yantao
    Wang, Shiliang
    MEASUREMENT, 2022, 198
  • [6] Off-axis digital holographic camera for quantitative phase microscopy
    Monemhaghdoust, Zahra
    Montfort, Frederic
    Emery, Yves
    Depeursinge, Christian
    Moser, Christophe
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (06): : 1721 - 1730
  • [7] Detectability of unresolved particles in off-axis digital holographic microscopy
    Johnston, Nikki
    Dubay, Megan Marie
    Serabyn, Eugene
    Nadeau, Jay L.
    APPLIED OPTICS, 2024, 63 (07) : B114 - B125
  • [8] Automatic cross filtering for off-axis digital holographic microscopy
    Zhong, Zhi
    Zhao, Hongjie
    Cao, Liangcai
    Shan, Mingguang
    Liu, Bin
    Lu, Wenlong
    Xie, Hong
    RESULTS IN PHYSICS, 2020, 16
  • [9] Slightly off-axis digital holographic microscopy with a divided aperture
    Zhao, Hongjie
    Zhong, Zhi
    Shan, Mingguang
    Liu, Bin
    Lu, Wenlong
    Xie, Hong
    OPTICS COMMUNICATIONS, 2020, 471
  • [10] Off-axis multispectral digital holographic microscope with partially coherent illumination
    Dubois, Frank
    Yourassowsky, Catherine
    OPTICAL MODELLING AND DESIGN II, 2012, 8429