Molecularly imprinted hornlike polymer@electrochemically reduced graphene oxide electrode for the highly selective determination of an antiemetic drug

被引:25
|
作者
Kumar, Deivasigamani Ranjith [1 ]
Dhakal, Ganesh [1 ]
Van Quang Nguyen [1 ,2 ]
Shim, Jae-Jin [1 ]
机构
[1] Yeungnam Univ, Sch Chem Engn, 280 Daehak Ro, Gyongsan 38541, Gyeongbuk, South Korea
[2] Univ Sci & Technol, Univ Da Nang, Dept Rd & Bridge Engn, 54 Nguyen Luong Bang, Da Nang, Vietnam
基金
新加坡国家研究基金会;
关键词
Polypyrrole; Molecularly imprinted polymer; Imprinting factor; Domperidone; Differential pulse voltammetry; FUNCTIONALIZED GRAPHENE; POLYPYRROLE; SENSOR; DOMPERIDONE; REDUCTION; NANOTUBES; COMPOSITE; WATER;
D O I
10.1016/j.aca.2020.10.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Robust, highly selective, and sensitive sensor devices are in high demand for the detection of bioactive molecules. Bioactive molecules are quantified by the electrochemical approach in the presence of other interference species, presenting a significant challenge to researchers. In this study, molecularly imprinted polymer (MIP) was prepared using the electrochemical method in a methanol/water solution mixture. The MIP on the electrochemically reduced graphene oxide (ERGO) surface exhibited hornlike morphology in contrast to the bare GC obtained, forming irregular bulky structures with a size range of 0.8-2.1 mu m. The domperidone (DP) binding/extraction from MIP@ERGO was studied using ex situ Fourier transform infrared and X-ray photoelectron spectroscopy. The hornlike MIP@ERGO/GC revealed a higher heterogeneous electron transfer rate constant and DP antiemetic drug oxidation current response compared with the MIP/GC and non-imprinted polymer (NIP/GC) electrodes. The hornlike MIP@ERGO/GC electrode fabrication was optimized in terms of the pyrrole polymerization cyclic voltammetry cycle number, monomer/template concentration, and incubation times. The fabricated MIP@ERGO/GC electrode demonstrated a wide concentration range of DP detection (from 0.5 to 17.2 mu M), and the limit of detection was found to be 3.8 nM, with a signal-to-noise ratio of 3. Moreover, the MIP@ERGO/GC electrode had excellent DP selectivity (with an imprinting factor of 4.20), even in the presence of ascorbic acid, uric acid, dopamine, xanthine, gelatin, glucose, sucrose, t-cysteine, folic acid, K+, Na+, Ca2+, CO32-, SO42-, and NO32- interferences. The MIP@ERGO/GC electrode was tested on a human urine sample, and DP recovery ranges between 98.4% and 100.87% were obtained. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:71 / 82
页数:12
相关论文
共 50 条
  • [31] A sensitive and selective chemiluminescence sensor for the determination of dopamine based on silanized magnetic graphene oxide-molecularly imprinted polymer
    Duan, Huimin
    Li, Lei
    Wang, Xiaojiao
    Wang, Yanhui
    Li, Jianbo
    Luo, Chuannan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2015, 139 : 374 - 379
  • [32] Electrochemical sensor based on molecularly imprinted polymer/reduced graphene oxide composite for simultaneous determination of uric acid and tyrosine
    Zheng, Weihua
    Zhao, Min
    Liu, Weifen
    Yu, Shangmin
    Niu, Liting
    Li, Gengen
    Li, Haifeng
    Liu, Weilu
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2018, 813 : 75 - 82
  • [33] Computational design, synthesis and utilization of a magnetic molecularly imprinted polymer on graphene oxide nanosheets for highly selective extraction and determination of buprenorphine in biological fluids and tablets
    Ganjavi, Farideh
    Ansari, Mehdi
    Kazemipour, Maryam
    Zeidabadinejad, Leila
    ANALYTICAL METHODS, 2018, 10 (43) : 5214 - 5226
  • [34] A highly sensitive and selective molecularly imprinted electrochemical sensor modified with TiO2-reduced graphene oxide nanocomposite for determination of podophyllotoxin in real samples
    Li, Yansheng
    Zhang, Si
    Li, Na
    Wang, Jin
    Jin, Chaofan
    Zheng, Liyan
    Cao, Qiue
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2020, 873
  • [35] Molecularly imprinted polymer based on upconversion nanoparticles for highly selective and sensitive determination of Ochratoxin A
    Yan Zhen
    Fang Guo-zhen
    JOURNAL OF CENTRAL SOUTH UNIVERSITY, 2019, 26 (03) : 515 - 523
  • [36] Electrochemical Sensor Based on Molecularly Imprinted Polymer and Graphene Modified Electrode for Determination of Methyl Parathion
    Wu, Jia-Wen
    Xie, Zhou-Jian
    Tan, Xue-Cai
    Hu, Qi
    Lei, Fu-Hou
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 48 (06) : 757 - 764
  • [37] Selective determination of chloramphenicol at trace level in milk samples by the electrode modified with molecularly imprinted polymer
    Alizadeh, Taher
    Ganjali, Mohamad Reza
    Zare, Mashaalah
    Norouzi, Parviz
    FOOD CHEMISTRY, 2012, 130 (04) : 1108 - 1114
  • [38] Polyfurfural-Electrochemically Reduced Graphene Oxide Modified Glassy Carbon Electrode for the Direct Determination of Nitrofurazone
    Ye, Fang
    Huang, Jianzhi
    Xu, Yongqun
    Zeng, Qiang
    Nan, Junmin
    Wang, Lishi
    ANALYTICAL LETTERS, 2018, 51 (05) : 728 - 741
  • [39] Simultaneous determination of dopamine, ascorbic acid and uric acid at electrochemically reduced graphene oxide modified electrode
    Yang, La
    Liu, Dong
    Huang, Jianshe
    You, Tianyan
    SENSORS AND ACTUATORS B-CHEMICAL, 2014, 193 : 166 - 172
  • [40] Electrochemical behavior of eriocitrin and highly sensitive determination based on an electrochemically reduced graphene oxide modified glassy carbon electrode
    Yao, Shuyu
    Cai, Wanling
    Liu, Lin
    Liao, Xueqing
    Tao, Kaili
    Feng, Fang
    Yang, Gongjun
    ANALYTICAL METHODS, 2016, 8 (18) : 3722 - 3729