Molecularly imprinted hornlike polymer@electrochemically reduced graphene oxide electrode for the highly selective determination of an antiemetic drug

被引:25
|
作者
Kumar, Deivasigamani Ranjith [1 ]
Dhakal, Ganesh [1 ]
Van Quang Nguyen [1 ,2 ]
Shim, Jae-Jin [1 ]
机构
[1] Yeungnam Univ, Sch Chem Engn, 280 Daehak Ro, Gyongsan 38541, Gyeongbuk, South Korea
[2] Univ Sci & Technol, Univ Da Nang, Dept Rd & Bridge Engn, 54 Nguyen Luong Bang, Da Nang, Vietnam
基金
新加坡国家研究基金会;
关键词
Polypyrrole; Molecularly imprinted polymer; Imprinting factor; Domperidone; Differential pulse voltammetry; FUNCTIONALIZED GRAPHENE; POLYPYRROLE; SENSOR; DOMPERIDONE; REDUCTION; NANOTUBES; COMPOSITE; WATER;
D O I
10.1016/j.aca.2020.10.014
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Robust, highly selective, and sensitive sensor devices are in high demand for the detection of bioactive molecules. Bioactive molecules are quantified by the electrochemical approach in the presence of other interference species, presenting a significant challenge to researchers. In this study, molecularly imprinted polymer (MIP) was prepared using the electrochemical method in a methanol/water solution mixture. The MIP on the electrochemically reduced graphene oxide (ERGO) surface exhibited hornlike morphology in contrast to the bare GC obtained, forming irregular bulky structures with a size range of 0.8-2.1 mu m. The domperidone (DP) binding/extraction from MIP@ERGO was studied using ex situ Fourier transform infrared and X-ray photoelectron spectroscopy. The hornlike MIP@ERGO/GC revealed a higher heterogeneous electron transfer rate constant and DP antiemetic drug oxidation current response compared with the MIP/GC and non-imprinted polymer (NIP/GC) electrodes. The hornlike MIP@ERGO/GC electrode fabrication was optimized in terms of the pyrrole polymerization cyclic voltammetry cycle number, monomer/template concentration, and incubation times. The fabricated MIP@ERGO/GC electrode demonstrated a wide concentration range of DP detection (from 0.5 to 17.2 mu M), and the limit of detection was found to be 3.8 nM, with a signal-to-noise ratio of 3. Moreover, the MIP@ERGO/GC electrode had excellent DP selectivity (with an imprinting factor of 4.20), even in the presence of ascorbic acid, uric acid, dopamine, xanthine, gelatin, glucose, sucrose, t-cysteine, folic acid, K+, Na+, Ca2+, CO32-, SO42-, and NO32- interferences. The MIP@ERGO/GC electrode was tested on a human urine sample, and DP recovery ranges between 98.4% and 100.87% were obtained. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页码:71 / 82
页数:12
相关论文
共 50 条
  • [21] An electrochemical sensor for selective determination of sulfamethoxazole in surface water using a molecularly imprinted polymer modified BDD electrode
    Zhao, Yang
    Yuan, Fang
    Quan, Xie
    Yu, Hongtao
    Chen, Shuo
    Zhao, Huimin
    Liu, Zhaoyang
    Hilal, Nidal
    ANALYTICAL METHODS, 2015, 7 (06) : 2693 - 2698
  • [22] A highly selective electrochemical sensor for 4-chlorophenol determination based on molecularly imprinted polymer and PDDA-functionalized graphene
    Wang, Bin
    Okoth, Otieno Kevin
    Yan, Kai
    Zhang, Jingdong
    SENSORS AND ACTUATORS B-CHEMICAL, 2016, 236 : 294 - 303
  • [23] Electrochemical sensor based on molecularly imprinted polymer reduced graphene oxide and gold nanoparticles modified electrode for detection of carbofuran
    Tan, Xuecai
    Hu, Qi
    Wu, Jiawen
    Li, Xiaoyu
    Li, Pengfei
    Yu, Huicheng
    Li, Xiaoyan
    Lei, Fuhou
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 220 : 216 - 221
  • [24] Novel molecularly imprinted polymer based on β-cyclodextrin@graphene oxide: Synthesis and application for selective diphenylamine determination
    Sedghi, Roya
    Heidari, Bahareh
    Yassari, Mehrasa
    JOURNAL OF COLLOID AND INTERFACE SCIENCE, 2017, 503 : 47 - 56
  • [25] Electrochemical Sensor for Determination of Chlorpyrifos Based on Graphene Modified Electrode and Molecularly Imprinted Polymer
    Tan Xue-Cai
    Wu Jia-Wen
    Hu Qi
    Li Xiao-Yu
    Li Peng-Fei
    Yu Hui-Cheng
    Li Xiao-Yan
    Lei Fu-Hou
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2015, 43 (03) : 387 - 393
  • [26] Development of a Redox-Label-Doped Molecularly Imprinted Polymer on β-Cyclodextrin/Reduced Graphene Oxide for Electrochemical Detection of a Stress Biomarker
    Goyal, Arpit
    Sakata, Toshiya
    ACS OMEGA, 2022, 7 (37): : 33491 - 33499
  • [27] Magnetic glass carbon electrode, modified with magnetic ferriferrous oxide nanoparticles coated with molecularly imprinted polymer films for electrochemical determination of bovine hemoglobin
    Sun, Si
    Chen, Lizhen
    Shi, Hejin
    Li, Yijun
    He, Xiwen
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2014, 734 : 18 - 24
  • [28] Highly selective extraction and voltammetric determination of the opioid drug buprenorphine via a carbon paste electrode impregnated with nano-sized molecularly imprinted polymer
    Taher Alizadeh
    Fatemeh Atashi
    Maedeh Akhoundian
    Mohammad Reza Ganjali
    Microchimica Acta, 2019, 186
  • [29] Amperometric determination of myo-inositol by using a glassy carbon electrode modified with molecularly imprinted polypyrrole, reduced graphene oxide and nickel nanoparticles
    Beluomini, Maisa Azevedo
    da Silva, Jose Luiz
    Stradiotto, Nelson Ramos
    MICROCHIMICA ACTA, 2018, 185 (03)
  • [30] Highly selective extraction and voltammetric determination of the opioid drug buprenorphine via a carbon paste electrode impregnated with nano-sized molecularly imprinted polymer
    Alizadeh, Taher
    Atashi, Fatemeh
    Akhoundian, Maedeh
    Ganjali, Mohammad Reza
    MICROCHIMICA ACTA, 2019, 186 (09)