Axial compressive behavior of square concrete columns reinforced with innovative closed-type winding GFRP stirrups

被引:65
作者
Dong, Heng-Lei [1 ,2 ,3 ]
Wang, Daiyu [1 ,2 ,3 ]
Wang, Zhenyu [1 ,2 ,3 ]
Sun, Yunlong [4 ]
机构
[1] Harbin Inst Technol, Minist Educ, Key Lab Struct Dynam Behav & Control, Harbin 150090, Heilongjiang, Peoples R China
[2] Harbin Inst Technol, Minist Ind & Informat Technol, Key Lab Smart Prevent & Mitigat Civil Engn Disast, Harbin 150090, Heilongjiang, Peoples R China
[3] Harbin Inst Technol, Sch Civil Engn, Harbin 150090, Heilongjiang, Peoples R China
[4] Harbin FRP Inst, Harbin 150000, Heilongjiang, Peoples R China
基金
中国国家自然科学基金;
关键词
FRP; Concrete columns; Axial compression; Confinement efficiency; Stirrups; FRP; BEAMS; DESIGN; STEEL; MODEL;
D O I
10.1016/j.compstruct.2018.02.092
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Conventional fiber-reinforced polymer (FRP) rod stirrups are characterized by at least one side overlap, where premature bond slip failure is likely to occur, resulting in low confinement efficiency. To overcome this shortcoming, an innovative closed-type winding glass FRP (CW-GFRP) stirrup was proposed by winding continuous filaments on the mould. This paper also presented an experimental study on the axial compressive behavior of 16 large-scale columns (300 x 300 x 900 mm), which were reinforced longitudinally with identical steel bars and transversely with different stirrups, namely steel, CW-GFRP or conventional GFRP rod stirrups. The confinement efficiency of these stirrups was compared regarding the failure modes, axial load capacity and ultimate axial strain. Test results indicated that columns reinforced with conventional GFRP rod stirrups exhibited bond slip failure after spalling of concrete cover, while CW-GFRP confined columns avoided this failure. The proposed CW-GFRP stirrups performed best in improving the ductility of columns. When stirrup spacing was 75 mm, an increase of 95% and 180% in ultimate axial strain was achieved for CW-GFRP confined columns compared with their steel and GFRP rod stirrup counterparts. Columns with CW-GFRP stirrups spaced at 50 mm exhibited monotonically ascending load-strain responses and achieved the ultimate strain up to 5.51%.
引用
收藏
页码:115 / 125
页数:11
相关论文
共 33 条
  • [11] Benmokrane B., 2014, ACI STRUCT J, P111
  • [12] Canadian Standards Association (CSA), 2012, CANCSAS80612
  • [13] Slenderness Effects on Circular CFRP Confined Reinforced Concrete Columns
    Fitzwilliam, Jason
    Bisby, Luke A.
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (03) : 280 - 288
  • [14] Experimental study of FRP tube encased concrete cylinders exposed to fire
    Ji, Gefu
    Li, Guoqiang
    Li, Xiugang
    Pang, Su-Seng
    Jones, Randy
    [J]. COMPOSITE STRUCTURES, 2008, 85 (02) : 149 - 154
  • [15] Cracking control comparison in the specifications of serviceability in cracking for FRP reinforced concrete beams
    Ju, Minkwan
    Park, Younghwan
    Park, Cheolwoo
    [J]. COMPOSITE STRUCTURES, 2017, 182 : 674 - 684
  • [16] Flexural performance of FRP reinforced concrete beams
    Kara, Ilker Fatih
    Ashour, Ashraf F.
    [J]. COMPOSITE STRUCTURES, 2012, 94 (05) : 1616 - 1625
  • [17] Bend Strength of Complete Closed-Type Carbon Fiber-Reinforced Polymer Stirrups with Rectangular Section
    Lee, C.
    Ko, M.
    Lee, Y.
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2014, 18 (01)
  • [18] Lee C, 2015, J COMPOS CONSTR
  • [19] Experimental Observation on the Effectiveness of Fiber Sheet Strip Stirrups in Concrete Beams
    Lee, Chadon
    Kim, Jun-Yeop
    Heo, Seo-Young
    [J]. JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2010, 14 (05) : 487 - 497
  • [20] Seismic behavior of corrosion-damaged reinforced concrete columns strengthened using combined carbon fiber-reinforced polymer and steel jacket
    Li, Jinbo
    Gong, Jinxin
    Wang, Licheng
    [J]. CONSTRUCTION AND BUILDING MATERIALS, 2009, 23 (07) : 2653 - 2663