Numerical investigation on the influence of circuit breaker structure parameters on vacuum arc behaviors

被引:4
|
作者
Zhao, Lihua [1 ]
Gou, Hangyuan [1 ]
Yang, Mengjie [1 ]
Hong, Guo [1 ]
Bai, Xueyan [2 ]
Huang, Xiaolong [1 ]
Ren, Junwen [1 ]
Ning, Wenjun [1 ]
Wang, Lijun [3 ]
机构
[1] Sichuan Univ, Coll Elect Engn, Chengdu 610065, Peoples R China
[2] State Grid Meishan Power Supply Co, Meishan 620010, Peoples R China
[3] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
high-current vacuum arc; external transverse magnetic field; vacuum circuit breaker; structural parameter changes; modeling and simulation; AXIAL MAGNETIC-FIELD; SIMULATION; INTERRUPTERS; EXPANSION; DENSITY; MOTION;
D O I
10.1088/1361-6463/abc9e5
中图分类号
O59 [应用物理学];
学科分类号
摘要
In a switchgear, an external transverse magnetic field (ETMF) is generated by the U type loop consisting of the vacuum interrupter, external busbar and conductive rod connected to the vacuum interrupter. The ETMF will make the vacuum arc deflected and strengthen the contraction of the arc. This can increase the probability of breaking failure. To weaken the adverse effect of the ETMF, the real magnetic field data of the arc area with different structure parameters when the length of conductive rod, external busbar and phase distance is changed are obtained by establishing simulation model in this paper. Taking the real magnetic field data as the boundary condition, this paper obtains the typical parameters of the vacuum arc plasma with different structure parameters by using the established three-dimensional high-current vacuum arc magnetohydrodynamics model. The simulation results show that the ETMF makes the transverse magnetic field (TMF) of the arc area asymmetric, which leads to an arc deflection. Reducing the length of the conductive rod connected to the vacuum interrupter to 50 mm can effectively improve the asymmetry of the TMF caused by the EMTF, weaken the arc deflection phenomenon, make the distribution of the plasma parameters more uniform, and increases the utilization of the anode contact surface. Moreover, it can not only reduce the heat flux density into the anode as a whole, but also reduce the heat flux density in the high heat flux density area, so as to effectively reduce the degree of anode activity and improve the negative effects caused by the anode activity. The changes of other external structural parameters have less influence on the improvement of the vacuum arc deflection phenomenon. Increasing the phase spacing to 275 mm or reducing the length of the external bus bar to 100 mm can only slightly weaken the arc deflection.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Influence of Bias Parameters and Plasma Density on Vacuum Arc Macroparticle Accumulation
    Ryabchikov, Alexander I.
    Sivin, Denis O.
    Bumagina, Anna I.
    MATERIALS AND MANUFACTURING PROCESSES, 2015, 30 (12) : 1471 - 1475
  • [42] Influence of Grading Capacitances on the Lightning Impulse Breakdown Voltage of a Double-Break Vacuum Circuit Breaker
    Liu, Pei
    Liu, Shaowei
    Hong, Lixin
    Yao, Xiaofei
    Liu, Zhiyuan
    Geng, Yingsan
    Wang, Jianhua
    PROCEEDINGS OF THE 2018 28TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV 2018), VOL 1, 2018, : 73 - 76
  • [43] Numerical modeling of arc root transfer during contact opening in a low-voltage air circuit breaker
    Wu, Yi
    Rong, MingZhe
    Yang, Fei
    Murphy, Anthony B.
    Ma, Qiang
    Sun, Zhiqiang
    Wang, Xiaohua
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2008, 36 (04) : 1074 - 1075
  • [44] Modeling and simulation of the influence of contact structure on the characteristics of high current vacuum arc plasma
    Zhao, Lihua
    Zhu, Haiyi
    Gou, Hangyuan
    Ren, Junwen
    Wang, Zhong
    Ning, Wenjun
    Wang, Lijun
    Huang, Xiaolong
    PHYSICS OF PLASMAS, 2020, 27 (08)
  • [45] Analysis and Design of Topological Structure for Bi-direction Forced Commutation DC Vacuum Circuit Breaker
    Liu L.
    Xue J.
    Ji F.
    Jiang W.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2022, 42 (21): : 8034 - 8040
  • [46] Investigation on Power Frequency Following Current for Vacuum Circuit Breaker Interrupting Shunt Reactor in Offshore Wind Farms
    Zheng, Zhi
    Zhong, Xiao
    Sun, Qiuqin
    Zhang, Jiahao
    Li, Xin
    Yuan, Jie
    Chen, Danhua
    Wu, Rong
    IEEE TRANSACTIONS ON POWER DELIVERY, 2024, 39 (01) : 306 - 316
  • [47] An experimental and numerical study to evaluate performance parameters of GIS circuit breaker during low current interruption
    Rao, Mandava Mohana
    Roy, Sonali Abhinav
    Kiran, Ravi
    INTERNATIONAL JOURNAL OF EMERGING ELECTRIC POWER SYSTEMS, 2024, 25 (04) : 471 - 484
  • [48] Numerical Investigation of Grain Structure Under the Rotating Arc Based on Cellular Automata-Finite Element Method During Vacuum Arc Remelting Process
    Cui, Jiajun
    Li, Baokuan
    Liu, Zhongqiu
    Xiong, Yongtao
    Qi, Fengsheng
    Zhao, Zibo
    Zhu, Shaoxiang
    METALLURGICAL AND MATERIALS TRANSACTIONS B-PROCESS METALLURGY AND MATERIALS PROCESSING SCIENCE, 2023, 54 (02): : 661 - 672
  • [49] Research on Test Influence of 12 kV Vacuum Circuit Breaker for Switching Capacitive Load Based on Measurement and Control
    Lang, Fucheng
    PROCEEDINGS OF THE 35TH CHINESE CONTROL CONFERENCE 2016, 2016, : 9942 - 9945
  • [50] Numerical investigation on the effect of axial magnetic field on metallurgical quality of ingots during vacuum arc remelting process
    Cui, Jiajun
    Li, Baokuan
    Liu, Zhongqiu
    Qi, Fengsheng
    Zhang, Xueping
    JOURNAL OF MATERIALS RESEARCH AND TECHNOLOGY-JMR&T, 2022, 20 : 1912 - 1926