Numerical investigation on the influence of circuit breaker structure parameters on vacuum arc behaviors

被引:4
|
作者
Zhao, Lihua [1 ]
Gou, Hangyuan [1 ]
Yang, Mengjie [1 ]
Hong, Guo [1 ]
Bai, Xueyan [2 ]
Huang, Xiaolong [1 ]
Ren, Junwen [1 ]
Ning, Wenjun [1 ]
Wang, Lijun [3 ]
机构
[1] Sichuan Univ, Coll Elect Engn, Chengdu 610065, Peoples R China
[2] State Grid Meishan Power Supply Co, Meishan 620010, Peoples R China
[3] Xi An Jiao Tong Univ, State Key Lab Elect Insulat & Power Equipment, Xian 710049, Peoples R China
基金
中国国家自然科学基金;
关键词
high-current vacuum arc; external transverse magnetic field; vacuum circuit breaker; structural parameter changes; modeling and simulation; AXIAL MAGNETIC-FIELD; SIMULATION; INTERRUPTERS; EXPANSION; DENSITY; MOTION;
D O I
10.1088/1361-6463/abc9e5
中图分类号
O59 [应用物理学];
学科分类号
摘要
In a switchgear, an external transverse magnetic field (ETMF) is generated by the U type loop consisting of the vacuum interrupter, external busbar and conductive rod connected to the vacuum interrupter. The ETMF will make the vacuum arc deflected and strengthen the contraction of the arc. This can increase the probability of breaking failure. To weaken the adverse effect of the ETMF, the real magnetic field data of the arc area with different structure parameters when the length of conductive rod, external busbar and phase distance is changed are obtained by establishing simulation model in this paper. Taking the real magnetic field data as the boundary condition, this paper obtains the typical parameters of the vacuum arc plasma with different structure parameters by using the established three-dimensional high-current vacuum arc magnetohydrodynamics model. The simulation results show that the ETMF makes the transverse magnetic field (TMF) of the arc area asymmetric, which leads to an arc deflection. Reducing the length of the conductive rod connected to the vacuum interrupter to 50 mm can effectively improve the asymmetry of the TMF caused by the EMTF, weaken the arc deflection phenomenon, make the distribution of the plasma parameters more uniform, and increases the utilization of the anode contact surface. Moreover, it can not only reduce the heat flux density into the anode as a whole, but also reduce the heat flux density in the high heat flux density area, so as to effectively reduce the degree of anode activity and improve the negative effects caused by the anode activity. The changes of other external structural parameters have less influence on the improvement of the vacuum arc deflection phenomenon. Increasing the phase spacing to 275 mm or reducing the length of the external bus bar to 100 mm can only slightly weaken the arc deflection.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] Experimental Investigation of Arc Characteristics in Medium-voltage DC Circuit Breaker
    Ren, Zhigang
    Ma, Ruiguang
    Sun, Hao
    Ning, Jiaqi
    Chen, Zhexin
    Niu, Chunping
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [22] Experimental Investigation on the Matching Characteristics of Vacuum Circuit Breaker with Double-break
    Ge, Guowei
    Liao, Minfu
    Duan, Xiongying
    Wang, Shanjun
    Cheng, Xian
    Zou, Jiyan
    PROCEEDINGS OF THE 2014 26TH INTERNATIONAL SYMPOSIUM ON DISCHARGES AND ELECTRICAL INSULATION IN VACUUM (ISDEIV-2014), 2014, : 493 - 496
  • [23] Probe Array Diagnosis of Vacuum Circuit Breaker Post-arc Sheath Development Process
    Cheng X.
    Chen H.
    Ge G.
    Chen L.
    Du S.
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2023, 43 (08): : 3227 - 3236
  • [24] The influence of electrode erosion on the air arc in a low-voltage circuit breaker
    Rong, Mingzhe
    Ma, Qiang
    Wu, Yi
    Xu, Tiejun
    Murphy, Anthony B.
    JOURNAL OF APPLIED PHYSICS, 2009, 106 (02)
  • [25] Experimental Investigation of the Prestrike Characteristics of a Double-Break Vacuum Circuit Breaker under DC Voltages
    Geng, Yun
    Yao, Xiaofei
    Dong, Jinlong
    Liu, Xue
    Geng, Yingsan
    Liu, Zhiyuan
    Peng, Jing
    Wang, Ke
    ENERGIES, 2020, 13 (12)
  • [26] Upon The Impact of Power System and Vacuum Circuit Breaker Parameters on Transient Recovery Voltage
    Soloot, Amir Hayati
    Hoidalen, Hans Kristian
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [27] The Parameters Identification of HVDC Circuit Breaker Arc Model based on Particle Swarm Optimization
    Shen Xiao-lin
    Huang Yu-long
    2011 INTERNATIONAL CONFERENCE ON ENVIRONMENTAL SYSTEMS SCIENCE AND ENGINEERING (ICESSE 2011), VOL 2, 2011, : 525 - 533
  • [28] Investigation on the Thermal Performance of a 363 kV Vacuum Circuit Breaker Using a 3D Coupled Model
    Yu, Xiao
    Yang, Fan
    Bing, Gao
    Liu, Heng
    Li, Xing
    Ai, Shaogui
    Wu, Xuxiang
    IEEE ACCESS, 2019, 7 : 128606 - 128616
  • [29] Numerical Simulation of Vacuum Arc Behavior Considering Action of Adjacent Phases in Vacuum Circuit Breakers
    Wang, Lijun
    Qin, Kang
    Hu, Lilan
    Zhang, Xiao
    Jia, Shenli
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2017, 45 (05) : 859 - 867
  • [30] Investigation on Reignition Probability of Switching Overvoltage Caused by Vacuum Circuit Breaker in Offshore Wind Farms
    Sun, Qiuqin
    Zheng, Zhi
    Huang, Lei
    Wang, Feng
    Zhong, Lipeng
    Chen, She
    IEEE TRANSACTIONS ON POWER DELIVERY, 2022, 37 (05) : 4438 - 4447