A Flexible Image-Guided Shape Reconstruction Framework for Electrical Impedance Tomography

被引:0
|
作者
Wang, Yu [2 ]
Dong, Feng [3 ]
Ren, Shangjie [1 ,3 ]
机构
[1] Tianjin Univ, Sch Elect & Informat Engn, Tianjin Key Lab Proc Measurement & Control, Tianjin 300072, Peoples R China
[2] Tianjin Univ, Tianjin, Peoples R China
[3] Tianjin Univ, Sch Elect & Informat Engn, Tianjin, Peoples R China
基金
中国国家自然科学基金;
关键词
Conductivity; Imaging; Reconstruction algorithms; Computed tomography; Conductivity estimation; electrical impedance tomography (EIT); image prior; shape reconstruction; statistical inverse problems; INFORMATION; SENSITIVITY; BOUNDARIES; SNAKES; SYSTEM; DOMAIN;
D O I
10.1109/TIM.2022.3218515
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Electrical impedance tomography (EIT) owns the advantages of safety, high temporal resolution, and functional imaging characteristics, thus is considered a promising medical/industrial imaging modality. However, due to the ill-posedness of its inverse problem, the spatial resolution of EIT is low, which greatly impeded its practical applications. A flexible image-guided inclusion boundary reconstruction (IGBR) framework for EIT is proposed to alleviate the problem. A statistical inverse problem framework for IGBR is established to directly reconstruct the inclusion boundary and the corresponding conductivity distribution. The morphology prior information is extracted from the images obtained from other high-resolution modes and is used to guide the boundary reconstruction (BR) process in the form of a conditional probability model. A series of simulation and experimental studies are carried out for different application backgrounds. The lung EIT imaging guided by computerized tomography (CT) image and EIT inclusion detection guided by B-ultrasound image is simulated and analyzed, respectively. The results show that the proposed method has high applicability to prior images of different modes. It not only achieves high-precision shape reconstruction but also high-precision conductivity estimation under the guidance of accurate prior images. Meanwhile, the proposed method has high robustness to the possible influence of noise in prior images or incomplete structural information. Even if the information in the prior image is biased or incomplete, the proposed method can still achieve high precision boundary reconstruction and conductivity estimation. The results of quantitative analysis show that compared with the method without image prior, the proposed method has an average reduction of 70% in area error (AE), while the conductivity estimation error is reduced by about five times on average.
引用
收藏
页数:13
相关论文
共 50 条
  • [1] Image Reconstruction of Electrical Impedance Tomography Based on Optical Image-Guided Group Sparsity
    Liu, Zhe
    Yang, Yunjie
    IEEE SENSORS JOURNAL, 2021, 21 (19) : 21893 - 21902
  • [2] CT Image-Guided Electrical Impedance Tomography for Medical Imaging
    Li, Ziang
    Zhang, Jie
    Liu, Dong
    Du, Jiangfeng
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2020, 39 (06) : 1822 - 1832
  • [3] A Statistical Shape-Constrained Reconstruction Framework for Electrical Impedance Tomography
    Ren, Shangjie
    Sun, Kai
    Liu, Dong
    Dong, Feng
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (10) : 2400 - 2410
  • [4] A Point Constrained Boundary Reconstruction Framework for Ultrasound Guided Electrical Impedance Tomography
    Ren, Shangjie
    Liang, Guanghui
    Dong, Feng
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2020, 6 (06) : 1336 - 1350
  • [5] A Moving Morphable Components Based Shape Reconstruction Framework for Electrical Impedance Tomography
    Liu, Dong
    Du, Jiangfeng
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2019, 38 (12) : 2937 - 2948
  • [6] AN IMAGE RECONSTRUCTION FRAMEWORK BASED ON DEEP NEURAL NETWORK FOR ELECTRICAL IMPEDANCE TOMOGRAPHY
    Li, Xiuyan
    Lu, Yang
    Wang, Jianming
    Dang, Xin
    Wang, Qi
    Duan, Xiaojie
    Sun, Yukuan
    2017 24TH IEEE INTERNATIONAL CONFERENCE ON IMAGE PROCESSING (ICIP), 2017, : 3585 - 3589
  • [7] Temporal image reconstruction in electrical impedance tomography
    Adler, Andy
    Dai, Tao
    Lionheart, William R. B.
    PHYSIOLOGICAL MEASUREMENT, 2007, 28 (07) : S1 - S11
  • [8] Gradient-Guided Multi-Modal Image Reconstruction for Electrical Impedance Tomography
    Liu, Zhe
    Dong, Huazhi
    Wang, Jiazheng
    Chen, Zhou
    Zhou, Wei
    Yang, Yunjie
    2023 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE, I2MTC, 2023,
  • [9] Model-Based Deep Unrolling Framework for Electrical Impedance Tomography Image Reconstruction
    Zhang, Baojie
    Zhang, Yuxiang
    Cheng, Zien
    Chen, Xiaoyan
    Fu, Feng
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2025, 74
  • [10] An image reconstruction framework based on boundary voltages for ultrasound modulated electrical impedance tomography
    Song, Xizi
    Xu, Yanbin
    Dong, Feng
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2016, 27 (11)