C-MAC Video Laryngoscope versus Conventional Direct Laryngoscopy for Endotracheal Intubation During Cardiopulmonary Resuscitation

被引:13
|
作者
Min, Byeong Chul [1 ]
Park, Jong Eun [1 ]
Lee, Gun Tak [1 ]
Kim, Tae Rim [1 ]
Yoon, Hee [1 ]
Cha, Won Chul [1 ]
Shin, Tae Gun [1 ]
Song, Keun Jeong [1 ]
Park, Minsu [2 ]
Han, Heewon [2 ]
Hwang, Sung Yeon [1 ]
机构
[1] Sungkyunkwan Univ, Samsung Med Ctr, Dept Emergency Med, Sch Med, Seoul 06351, South Korea
[2] Samsung Med Ctr, Stat & Data Ctr, Seoul 06351, South Korea
来源
MEDICINA-LITHUANIA | 2019年 / 55卷 / 06期
关键词
airway management; tracheal intubation; direct laryngoscopy; video laryngoscope; cardiac arrest; EMERGENCY-DEPARTMENT; DIFFICULT AIRWAY; LIFE-SUPPORT; GUIDELINES; SUCCESS;
D O I
10.3390/medicina55060225
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives: To compare the first pass success (FPS) rate of the C-MAC video laryngoscope (C-MAC) and conventional Macintosh-type direct laryngoscopy (DL) during cardiopulmonary resuscitation (CPR) in the emergency department (ED). Materials and Methods: This study was a single-center, retrospective study conducted from April 2014 to July 2018. Patients were categorized into either the C-MAC or DL group, according to the device used on the first endotracheal intubation (ETI) attempt. The primary outcome was the FPS rate. A multiple logistic regression model was developed to identify factors related to the FPS. Results: A total of 573 ETIs were performed. Of the eligible cases, 263 and 310 patients were assigned to the C-MAC and DL group, respectively. The overall FPS rate was 75% (n = 431/573). The FPS rate was higher in the C-MAC group than in the DL group, but there was no statistically significant difference (total n = 431, 79% compared to 72%, p = 0.075). In the multiple logistic regression analysis, the C-MAC use had higher FPS rate (adjusted odds ratio: 1.80; 95% CI, 1.17-2.77; p = 0.007) than that of the DL use. Conclusions: The C-MAC use on the first ETI attempt during cardiopulmonary resuscitation in the emergency department had a higher FPS rate than that of the DL use.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Video laryngoscopy versus direct laryngoscopy for tracheal intubation during in-hospital cardiopulmonary resuscitation
    Lee, Dong Hyun
    Han, Myongja
    An, Ji Young
    Jung, Ji Young
    Koh, Younsuck
    Lim, Chae-Man
    Huh, Jin Won
    Hong, Sang-Bum
    RESUSCITATION, 2015, 89 : 195 - 199
  • [2] Endotracheal intubation using the C-MAC® video laryngoscope or the Macintosh laryngoscope: A prospective, comparative study in the ICU
    Ruediger R Noppens
    Stephanie Geimer
    Nicole Eisel
    Matthias David
    Tim Piepho
    Critical Care, 16
  • [3] A Comparison of the C-MAC Video Laryngoscope to the Macintosh Direct Laryngoscope for Intubation in the Emergency Department
    Sakles, John C.
    Mosier, Jarrod
    Chiu, Stephen
    Cosentino, Mari
    Kalin, Leah
    ANNALS OF EMERGENCY MEDICINE, 2012, 60 (06) : 739 - 748
  • [4] Intubation in the Intensive Care Unit: C-MAC video laryngoscope versus Macintosh laryngoscope
    Dey, S.
    Pradhan, D.
    Saikia, P.
    Bhattacharyya, P.
    Khandelwal, H.
    Adarsha, K. N.
    MEDICINA INTENSIVA, 2020, 44 (03) : 135 - 141
  • [5] A randomized comparative evaluation of C-MAC video-laryngoscope with Miller laryngoscope for neonatal endotracheal intubation
    Goel, Sachin
    Choudhary, Ripon
    Magoon, Rohan
    Sharma, Ridhima
    Usha, G.
    Kapoor, Poonam M.
    Bagga, Deepak
    JOURNAL OF ANAESTHESIOLOGY CLINICAL PHARMACOLOGY, 2022, 38 (03) : 464 - 468
  • [6] Direct laryngoscopy or C-MAC video laryngoscopy? Routine tracheal intubation in patients undergoing ENT surgery
    Meininger, D.
    Strouhal, U.
    Weber, C. F.
    Fogl, D.
    Holzer, L.
    Zacharowski, K.
    Byhahn, C.
    ANAESTHESIST, 2010, 59 (09): : 806 - 811
  • [7] THE UTILITY OF THE C-MAC AS A DIRECT LARYNGOSCOPE FOR INTUBATION IN THE EMERGENCY DEPARTMENT
    Sakles, John C.
    Mosier, Jarrod M.
    Patanwala, Asad E.
    Arcaris, Brittany
    Dicken, John M.
    JOURNAL OF EMERGENCY MEDICINE, 2016, 51 (04) : 349 - 357
  • [8] Comparative Performance of C-MAC Video Laryngoscope and Macintosh Direct Laryngoscope for Emergency Intubation
    Xue, Fu S.
    Liao, Xu
    Cheng, Yi
    ANNALS OF EMERGENCY MEDICINE, 2012, 60 (06) : 817 - 818
  • [9] Comparison of the C-MAC video laryngoscope with direct Macintosh laryngoscopy in the emergency department
    Vassiliadis, John
    Tzannes, Alex
    Hitos, Kerry
    Brimble, Jessica
    Fogg, Toby
    EMERGENCY MEDICINE AUSTRALASIA, 2015, 27 (02) : 119 - 125
  • [10] Tracheal intubation using the mobile C-MAC video laryngoscope or direct laryngoscopy for patients with a simulated difficult airway
    Byhahn, C.
    Iber, T.
    Zacharowski, K.
    Weber, C. F.
    Ruesseler, M.
    Schalk, R.
    Meininger, D.
    MINERVA ANESTESIOLOGICA, 2010, 76 (08) : 577 - 583