Tabletop x-ray ghost imaging with ultra-low radiation

被引:351
作者
Zhang, Ai-Xin [1 ,2 ]
He, Yu-Hang [1 ,2 ]
Wu, Ling-An [1 ,2 ]
Chen, Li-Ming [1 ,2 ,3 ,4 ]
Wang, Bing-Bing [1 ,2 ]
机构
[1] Chinese Acad Sci, Inst Phys, Beijing 100191, Peoples R China
[2] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
[3] Shanghai Jiao Tong Univ, CICIFSA, Shanghai 200240, Peoples R China
[4] Shanghai Jiao Tong Univ, Dept Phys & Astron, Shanghai 200240, Peoples R China
基金
国家重点研发计划; 中国国家自然科学基金;
关键词
ILLUMINATION; MICROSCOPY; LIGHT;
D O I
10.1364/OPTICA.5.000374
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Computational ghost imaging, in which an image is retrieved from a known patterned field that illuminates an object and the total transmitted intensity therefrom, has seen great advances on account of its advantages and potential applications at all wavelengths. However, even though lensless x-ray ghost imaging was anticipated more than a decade ago, its development has been hampered due to the lack of suitable optics. The image quality is proportional to the total flux in conventional projection x-ray imaging, but high photon energy could severely damage the object being imaged, so decreasing the radiation dose while maintaining image quality is a fundamental problem. Using a simple tabletop x-ray source, we have successfully realized ghost imaging of planar and natural objects with a much higher contrast-to-noise ratio compared to projection x-ray imaging at the same low-radiation dose. Ultra-low-flux imaging has been achieved, and thus radiation damage of biological specimens could be greatly reduced with this new technique. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:374 / 377
页数:4
相关论文
共 27 条
[1]   Asic developments for radiation imaging applications: The medipix and timepix family [J].
Ballabriga, Rafael ;
Campbell, Michael ;
Llopart, Xavier .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 :10-23
[2]   Ghost imaging with a single detector [J].
Bromberg, Yaron ;
Katz, Ori ;
Silberberg, Yaron .
PHYSICAL REVIEW A, 2009, 79 (05)
[3]   A single-pixel terahertz imaging system based on compressed sensing [J].
Chan, Wai Lam ;
Charan, Kriti ;
Takhar, Dharmpal ;
Kelly, Kevin F. ;
Baraniuk, Richard G. ;
Mittleman, Daniel M. .
APPLIED PHYSICS LETTERS, 2008, 93 (12)
[4]   Ghost imaging through turbulent atmosphere [J].
Cheng, Jing .
OPTICS EXPRESS, 2009, 17 (10) :7916-7921
[5]   Ghost imaging: from quantum to classical to computational [J].
Erkmen, Baris I. ;
Shapiro, Jeffrey H. .
ADVANCES IN OPTICS AND PHOTONICS, 2010, 2 (04) :405-450
[6]   Surpassing the lateral resolution limit by a factor of two using structured illumination microscopy [J].
Gustafsson, MGL .
JOURNAL OF MICROSCOPY, 2000, 198 (02) :82-87
[7]   Ghost imaging with atoms [J].
Khakimov, R. I. ;
Henson, B. M. . ;
Shin, D. K. ;
Hodgman, S. S. ;
Dall, R. G. ;
Baldwin, K. G. H. ;
Truscott, A. G. .
NATURE, 2016, 540 (7631) :100-+
[8]   High-energy x-ray backlighter spectrum measurements using calibrated image plates [J].
Maddox, B. R. ;
Park, H. S. ;
Remington, B. A. ;
Izumi, N. ;
Chen, S. ;
Chen, C. ;
Kimminau, G. ;
Ali, Z. ;
Haugh, M. J. ;
Ma, Q. .
REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (02)
[9]   X-ray phase imaging with a paper analyzer [J].
Morgan, Kaye S. ;
Paganin, David M. ;
Siu, Karen K. W. .
APPLIED PHYSICS LETTERS, 2012, 100 (12)
[10]   Sub-Rayleigh imaging via speckle illumination [J].
Oh, Joo-Eon ;
Cho, Young-Wook ;
Scarcelli, Giuliano ;
Kim, Yoon-Ho .
OPTICS LETTERS, 2013, 38 (05) :682-684