Operational performance of a cryogenic loop heat pipe with insufficient working fluid inventory

被引:23
|
作者
Mo, Qing [1 ]
Liang, Jingtao
机构
[1] Chinese Acad Sci, Cryogen Lab, Tech Inst Phys & Chem, POB 2711, Beijing 100080, Peoples R China
[2] Grad Univ Chinese Acad Sci, Beijing 100039, Peoples R China
基金
英国工程与自然科学研究理事会;
关键词
cryogenics; heat pipe; heat transfer; experiment;
D O I
10.1016/j.ijrefrig.2005.10.011
中图分类号
O414.1 [热力学];
学科分类号
摘要
A cryogenic loop heat pipe (CLHP) has been developed for future aerospace applications at the Technical Institute of Physics and Chemistry (TIPC). It has been demonstrated that this CLHP, when placed horizontally, can operate in liquid-nitrogen temperature range and have a heat transfer capability of up to 12 W with proper working fluid inventory. This paper presents some particular characteristics of the CLHP when the compensation chamber is half-filled with liquid-phase working fluid before startup. The device has been tested at different orientations using nitrogen as the working fluid in order to compare its thermal behavior, specially related to the heat transfer capability, the operation temperature and the thermal resistance, as well as to investigate its operational characteristics under power level as low as I W. Tests were performed for the CLHP at horizontal position and with the liquid line 3.4 and 6.4 cm below the vapor line, respectively. The experimental results show the operationability of the CLHP tested at three orientations and tests with the liquid line 6.4 cm below the vapor line show lower operation temperatures and higher heat transfer capability. (c) 2005 Elsevier Ltd and IIR. All rights reserved.
引用
收藏
页码:519 / 527
页数:9
相关论文
共 50 条
  • [21] EFFECT OF WORKING FLUID ON PULSATING HEAT PIPE THERMAL PERFORMANCE
    Fumoto, Koji
    Kawaji, Masahiro
    Kawanami, Tsuyoshi
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010, VOL 5: FUEL CELLS, GAS TURBINES, HEAT PIPES, JET IMPINGEMENT, RADIATION, 2010, : 393 - 399
  • [22] EXPERIMENTAL INVESTIGATION OF THE WORKING PERFORMANCE OF A NOVEL MINIATURE LOOP HEAT PIPE
    Wang, Xiao-Wu
    Wan, Zhen-Ping
    Tang, Yong
    JOURNAL OF ENHANCED HEAT TRANSFER, 2013, 20 (06) : 481 - 489
  • [23] Effects of Working Fluids on Operating Characteristics of the Cryogenic Loop Heat Pipe in 180~230 K
    Liu C.
    Xie R.
    Wu Y.
    Gongcheng Kexue Yu Jishu/Advanced Engineering Sciences, 2020, 52 (06): : 190 - 198
  • [24] Operating characteristics of a miniature cryogenic loop heat pipe
    Bai, Lizhan
    Lin, Guiping
    Zhang, Hongxing
    Miao, Jianyin
    Wen, Dongsheng
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2012, 55 (25-26) : 8093 - 8099
  • [25] THERMAL MANAGEMENT OF A NITROGEN CRYOGENIC LOOP HEAT PIPE
    Gully, Ph.
    Yan, T.
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 55A AND 55B, 2010, 1218 : 1173 - +
  • [26] Effect of Amount of Fluid Charge in Thermal Performance of Loop Heat Pipe
    Nagano, Hosei
    Onogawa, Ei
    Fukuyoshi, Fuyuko
    Ogawa, Hiroyuki
    Nagai, Hiroki
    HEAT TRANSFER-ASIAN RESEARCH, 2010, 39 (06): : 355 - 364
  • [27] Influence of Working Fluid Amount and Working Position Gravitational Heat Pipe on Thermal Performance
    Jobb, Marian
    Nemec, Patrik
    Kosa, L'ubos
    Malcho, Milan
    XIX.THE APPLICATION OF EXPERIMENTAL AND NUMERICAL METHODS IN FLUID MECHANICS AND ENERGETICS 2014, 2014, 1608 : 88 - 91
  • [28] Experimental study on a cryogenic loop heat pipe with high heat capacity
    Zhao, Ya'nan
    Yan, Tao
    Liang, Jingtao
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2011, 54 (15-16) : 3304 - 3308
  • [29] Experimental validation of heat switch capability of cryogenic loop heat pipe
    Cho, Hyokjin
    Jin, Lingxue
    Kim, Seokho
    Jeong, Sangkwon
    CRYOGENICS, 2022, 121
  • [30] PARAMETRIC BEHAVIOUR OF CLOSED LOOP PULSATING HEAT PIPE IN THE PRESENCE OF WATER AS A WORKING FLUID
    Yadav, Nagendra P.
    Madhuri
    Kumar, Anil
    PROCEEDINGS OF THE ASME GAS TURBINE INDIA CONFERENCE, 2019, VOL 1, 2020,