Importance of angle correction in transcranial color-coded duplex insonation of arteries at the base of the brain

被引:6
|
作者
Lepic, Toplica [1 ]
Veljancic, Dragana [1 ]
Jovanikic, Olivera [2 ]
Lepic, Milan [2 ]
Slankamenac, Petar [3 ,4 ]
Raicevic, Ranko [1 ,5 ]
机构
[1] Mil Med Acad, Neurol Clin, Belgrade 11000, Serbia
[2] Mil Med Acad, Clin Neurosurg, Belgrade 11000, Serbia
[3] Clin Ctr Vojvodina, Neurol Clin, Novi Sad, Serbia
[4] Univ Novi Sad, Fac Med, Novi Sad, Serbia
[5] Univ Def, Mil Med Acad, Fac Med, Belgrade, Serbia
关键词
ultrasonography; doppler; transcranial; duplex; blood flow velocity; carotid artery; internal; anterior cerebral artery; middle cerebral artery; BLOOD-FLOW VELOCITY; DOPPLER SONOGRAPHY; CEREBRAL-ARTERIES; CLINICAL-APPLICATIONS;
D O I
10.2298/VSP141105009L
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Aim. Transcranial color-coded duplex (TCCD) sonography allows visualization of the vessels being examined and measurement of the angle of insonation. The published literature suggests that blood vessels are insonated at the angle lower than 30 degrees, hence no correction for the angle is necessary. The aim of this study was to determine the availability of intracranial blood vessels for insonation, and the percentage of arteries and their segments which can be insonated at the angles lower than 30 degrees. Methods. The study included 120 patients (mean age 51). For each of the segments the angle of insonation was registered based on TCCD vizualization, and hemodynamic parameters were measured. The angle of insonation was measured using combined B-mode and color Doppler vizualization, as the angle between the direction of the ultrasound beam and the axis of the shown arterial segment. Results. The total success rate of insonation was 86.33% (1,554 out of 1,800). The mean angle of insonation value in all the examined arterial segments was 42 degrees. The insonation angle was higher than 30 degrees in about three quarters of the examined segments, especially in the A2 segment of the anterior cerebral artery (98%), the P1 segmet of the posterior cerebral artery (87%) and in the terminal internal carotid artery (83%). The A1 segment of the anterior cerebral artery showed the best insonation conditions with the angle of insonation lower than 30 degrees in 53% of the cases. Conclusion. The presented results of angles of insonation measurements for the anterior, middle and posterior cerebral arteries and their segments, as well as the terminal portion of the internal carotid artery clearly indicate that their average values in tested segments were very often higher than 30 degrees, which can cause an error in blood flow velocity measurement that cannot be ignored. The results confirm the necessity of correcting flow velocity values on the basis of the angle of insonation in TCCD sonography.
引用
收藏
页码:1093 / 1097
页数:5
相关论文
共 50 条
  • [31] Three-dimensional transcranial color-coded sonography of cerebral aneurysms
    Klötzsch, C
    Bozzato, A
    Lammers, G
    Mull, M
    Lennartz, B
    Noth, J
    STROKE, 1999, 30 (11) : 2285 - 2290
  • [32] Development of a prediction model for facilitating the clinical application of transcranial color-coded duplex ultrasonography
    Duan, Jieyu
    Wang, Pengfei
    Wang, Haoyu
    Zhao, Wei
    BMC MEDICAL IMAGING, 2024, 24 (01)
  • [33] Contrast-enhanced transcranial color-coded duplex sonography in ischemic cerebrovascular disease
    Baumgartner, RW
    Arnold, M
    Gonner, F
    Staikow, I
    Herrmann, C
    Rivoir, A
    Muri, RM
    STROKE, 1997, 28 (12) : 2473 - 2478
  • [34] Visualization of the basilar artery by transcranial color-coded duplex sonography - Comparison with postmortem results
    Schulte-Altedorneburg, G
    Droste, DW
    Popa, V
    Wohlgemuth, WA
    Kellermann, M
    Nabavi, DG
    Csiba, L
    Ringelstein, B
    STROKE, 2000, 31 (05) : 1123 - 1127
  • [35] Evaluation of cerebral autoregulation in dogs via transcranial color-coded duplex sonography and transient hyperemia testing
    Donati, Pablo A.
    Tarragona, Lisa
    Zaccagnini, Andrea S.
    Nigro, Nestor M.
    Diaz, Alfredo J.
    Fuensalida, Santiago E.
    Sandez Cordero, Ignacio
    Espineira, Ignacio M.
    Otero, Pablo E.
    JOURNAL OF VETERINARY EMERGENCY AND CRITICAL CARE, 2024, 34 (06) : 554 - 559
  • [36] Stenosis in Middle Cerebral Artery Duplication Assessment With Transcranial Color-Coded Duplex Sonography
    Gomez-Choco, Manuel
    Nedelmann, Max
    Valdueza, Jose M.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2016, 35 (09) : 2053 - 2056
  • [37] Suitability of temporal bone acoustic window: Conventional TCD versus transcranial color-coded duplex sonography
    Krejza, Jaroslaw
    Swiat, Maciej
    Pawlak, Mikolaj A.
    Oszkinis, Grzegorz
    Weigele, John
    Hurst, Robert W.
    Kasner, Scott
    JOURNAL OF NEUROIMAGING, 2007, 17 (04) : 311 - 314
  • [38] Development of a prediction model for facilitating the clinical application of transcranial color-coded duplex ultrasonography
    Jieyu Duan
    Pengfei Wang
    Haoyu Wang
    Wei Zhao
    BMC Medical Imaging, 24
  • [39] Transcranial Color-Coded Duplex Ultrasound for Assessing Cerebrovascular Reserve in Intracranial Dissection with Aneurysm
    Venketasubramanian, Narayanaswamy
    Tan, Andrew Eik Hock
    Neo, Wee Thong
    Taneja, Manish
    CASE REPORTS IN NEUROLOGY, 2020, 12 (SUPPL 1) : 119 - 126
  • [40] RELEVANCE OF COLOR-CODED DUPLEX SONOGRAPHY IN NEPHROLOGY
    HOLLENBECK, M
    KRUMME, B
    GRABENSEE, B
    NIEREN-UND HOCHDRUCKKRANKHEITEN, 1994, 23 (06) : 287 - 294