Importance of angle correction in transcranial color-coded duplex insonation of arteries at the base of the brain

被引:6
|
作者
Lepic, Toplica [1 ]
Veljancic, Dragana [1 ]
Jovanikic, Olivera [2 ]
Lepic, Milan [2 ]
Slankamenac, Petar [3 ,4 ]
Raicevic, Ranko [1 ,5 ]
机构
[1] Mil Med Acad, Neurol Clin, Belgrade 11000, Serbia
[2] Mil Med Acad, Clin Neurosurg, Belgrade 11000, Serbia
[3] Clin Ctr Vojvodina, Neurol Clin, Novi Sad, Serbia
[4] Univ Novi Sad, Fac Med, Novi Sad, Serbia
[5] Univ Def, Mil Med Acad, Fac Med, Belgrade, Serbia
关键词
ultrasonography; doppler; transcranial; duplex; blood flow velocity; carotid artery; internal; anterior cerebral artery; middle cerebral artery; BLOOD-FLOW VELOCITY; DOPPLER SONOGRAPHY; CEREBRAL-ARTERIES; CLINICAL-APPLICATIONS;
D O I
10.2298/VSP141105009L
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background/Aim. Transcranial color-coded duplex (TCCD) sonography allows visualization of the vessels being examined and measurement of the angle of insonation. The published literature suggests that blood vessels are insonated at the angle lower than 30 degrees, hence no correction for the angle is necessary. The aim of this study was to determine the availability of intracranial blood vessels for insonation, and the percentage of arteries and their segments which can be insonated at the angles lower than 30 degrees. Methods. The study included 120 patients (mean age 51). For each of the segments the angle of insonation was registered based on TCCD vizualization, and hemodynamic parameters were measured. The angle of insonation was measured using combined B-mode and color Doppler vizualization, as the angle between the direction of the ultrasound beam and the axis of the shown arterial segment. Results. The total success rate of insonation was 86.33% (1,554 out of 1,800). The mean angle of insonation value in all the examined arterial segments was 42 degrees. The insonation angle was higher than 30 degrees in about three quarters of the examined segments, especially in the A2 segment of the anterior cerebral artery (98%), the P1 segmet of the posterior cerebral artery (87%) and in the terminal internal carotid artery (83%). The A1 segment of the anterior cerebral artery showed the best insonation conditions with the angle of insonation lower than 30 degrees in 53% of the cases. Conclusion. The presented results of angles of insonation measurements for the anterior, middle and posterior cerebral arteries and their segments, as well as the terminal portion of the internal carotid artery clearly indicate that their average values in tested segments were very often higher than 30 degrees, which can cause an error in blood flow velocity measurement that cannot be ignored. The results confirm the necessity of correcting flow velocity values on the basis of the angle of insonation in TCCD sonography.
引用
收藏
页码:1093 / 1097
页数:5
相关论文
共 50 条
  • [1] Evaluation of Cerebral Hemodynamics with Color-Coded Duplex Sonography: Normative Values with Correction of Insonation Angles
    Domingo Barrientos-Guerra, Jose
    Flores-Silva, Fernando
    Cantu-Brito, Carlos
    Chiquete, Erwin
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2020, 29 (03):
  • [2] Competence for transcranial color-coded Duplex sonography is rapidly acquired
    Klinzing, S.
    Steiger, P.
    Schuepbach, R. A.
    Bechir, M.
    Brandi, G.
    MINERVA ANESTESIOLOGICA, 2015, 81 (03) : 298 - 304
  • [3] Transcranial Color-Coded Sonography With Angle Correction As a Screening Tool for Raised Intracranial Pressure
    Rajajee, Venkatakrishna
    Soroushmehr, Reza
    Williamson, Craig A.
    Najarian, Kayvan
    Ward, Kevin
    Tiba, Hakam
    CRITICAL CARE EXPLORATIONS, 2023, 5 (09) : E0953
  • [4] Assessment of dural arteriovenous fistulae by transcranial color-coded duplex sonography
    Harrer, JU
    Popescu, O
    Henkes, HH
    Klötzsch, C
    STROKE, 2005, 36 (05) : 976 - 979
  • [5] Assessment of intracranial collateral flow by transcranial color-coded duplex sonography using a temporal and frontal axial insonation plane
    Stolz, E
    Mendes, I
    Gerriets, T
    Kaps, M
    JOURNAL OF NEUROIMAGING, 2002, 12 (02) : 136 - 143
  • [6] ASSESSING CIRCLE OF WILLIS BLOOD CIRCULATION IN DOGS WITH TRANSCRANIAL COLOR-CODED DUPLEX SONOGRAPHY
    Duque, Francisco J.
    Dominguez-Roldan, Jose M.
    Ruiz, Patricia
    Zaragoza, Concepcion
    Barrera-Chacon, Rafael
    VETERINARY RADIOLOGY & ULTRASOUND, 2009, 50 (05) : 530 - 535
  • [7] Frontal bone windows for transcranial color-coded duplex sonography
    Stolz, E
    Kaps, M
    Kern, A
    Dorndorf, W
    STROKE, 1999, 30 (04) : 814 - 820
  • [8] Clinical applications of transcranial color-coded duplex sonography
    Krejza, J
    Baumgartner, RW
    JOURNAL OF NEUROIMAGING, 2004, 14 (03) : 215 - 225
  • [9] Collateral configuration of the circle of Willis -: Transcranial color-coded duplex ultrasonography and comparison with postmortem anatomy
    Hoksbergen, AWJ
    Fülesdi, B
    Legemate, DA
    Csiba, L
    STROKE, 2000, 31 (06) : 1346 - 1351
  • [10] Point of Care Transcranial Color-Coded Duplex Ultrasound of the Middle Cerebral Artery
    Tarzi, Fawaz Philip
    Bulic, Sebina
    Ho, Stacey
    Saini, Pravesh
    Alexandrov, Andrei
    Bronshteyn, Yuriy S.
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (210):